Q2A
Driving quality - Q2A tailored application drive
- Open/closed loop speed or torque control
- Embedded functional safety (STO SIL3)
- Built-in C3 class EMC filter
- Conform to EN 60721-3-3, 3S2 and 3C2
- Built-in braking transistor (up to 90 kW)
- Quick and easy setup with intuitive keypad and navigation
- Micro SD for data storage
- Real-Time Clock
- 24 VDC power supply input for control board
- Communication options: EtherCAT, EtherNet/IP, PROFINET, POWERLINK
- Mobile Device connectivity (via USB or optional Bluetooth)
- Regenerative solutions as option
- CE, UL, cUL, EAC, RoHS
Specifications & ordering info
Ordering information
*1 With optional LCD remote operator model with Bluetooth.
Q2A inverter
Specifications | Order code | ||||
---|---|---|---|---|---|
Voltage | Heavy Duty (HD) | Normal Duty (HD) | |||
Max motor (kW) | Rated current (A) | Max motor (kW) | Rated current (A) | ||
200 V | 0.55 | 3.2 | 0.75 | 3.5 | Q2A-A2004-AAA |
0.75 | 5.0 | 1.1 | 6 | Q2A-A2006-AAA | |
1.5 | 8.0 | 2.2 | 9.6 | Q2A-A2010-AAA | |
2.2 | 11 | 3.0 | 12.2 | Q2A-A2012-AAA | |
4.0 | 17.5 | 5.5 | 21 | Q2A-A2021-AAA | |
5.5 | 25 | 7.5 | 30 | Q2A-A2030-AAA | |
7.5 | 33 | 11 | 42 | Q2A-A2042-AAA | |
11 | 47 | 15 | 56 | Q2A-A2056-AAA | |
15 | 60 | 18.5 | 70 | Q2A-A2070-AAA | |
18.5 | 75 | 22 | 82 | Q2A-A2082-AAA | |
22 | 88 | 30 | 110 | Q2A-A2110-AAA | |
30 | 115 | 37 | 138 | Q2A-A2138-AAA | |
37 | 145 | 45 | 169 | Q2A-A2169-AAA | |
45 | 180 | 55 | 211 | Q2A-A2211-AAA | |
55 | 215 | 75 | 257 | Q2A-A2257-AAA | |
75 | 283 | 90 | 313 | Q2A-A2313-AAA | |
90 | 346 | 110 | 360 | Q2A-A2360-AAA | |
110 | 415 | – | Q2A-A2415-AAA |
Specifications | Order code | ||||||||
---|---|---|---|---|---|---|---|---|---|
Voltage | Heavy Duty (HD) < 460 V | Heavy Duty (HD) ≥ 460 V | Normal Duty (ND) < 460 V | Normal Duty (ND) ≥ 460 V | |||||
Max motor (kW) |
Rated current (A) |
Max motor (kW) |
Rated current (A) |
Max motor (kW) |
Rated current (A) |
Max motor (kW) |
Rated current (A) |
||
400 V | 0.55 | 1.8 | 0.55 | 1.6 | 0.75 | 2.1 | 0.75 | 2.1 | Q2A-A4002-AAA |
0.75 | 3.4 | 0.75 | 2.1 | 1.5 | 4.1 | 1.5 | 3.4 | Q2A-A4004-AAA | |
1.5 | 4.8 | 1.5 | 3.4 | 2.2 | 5.4 | 2.2 | 4.8 | Q2A-A4005-AAA | |
2.2 | 5.5 | 2.2 | 4.8 | 3.0 | 7.1 | 3.0 | 6.9 | Q2A-A4007-AAA | |
3.0 | 7.2 | 3.0 | 6.9 | 3.7 | 8.9 | 3.7 | 7.6 | Q2A-A4009-AAA | |
3.7 | 9.2 | 3.7 | 7.6 | 5.5 | 11.9 | 5.5 | 11 | Q2A-A4012-AAA | |
5.5 | 14.8 | 5.5 | 11 | 7.5 | 17.5 | 7.5 | 14 | Q2A-A4018-AAA | |
7.5 | 18 | 7.5 | 14 | 11 | 23.4 | 11 | 21 | Q2A-A4023-AAA | |
11 | 24 | 11 | 21 | 15 | 31 | 15 | 27 | Q2A-A4031-AAA | |
15 | 31 | 15 | 27 | 18.5 | 38 | 18.5 | 34 | Q2A-A4038-AAA | |
18.5 | 39 | 18.5 | 34 | 22 | 44 | 22 | 40 | Q2A-A4044-AAA | |
22 | 45 | 22 | 40 | 30 | 59.6 | 30 | 52 | Q2A-A4060-AAA | |
30 | 60 | 30 | 52 | 37 | 74.9 | 37 | 65 | Q2A-A4075-AAA | |
37 | 75 | 37 | 65 | 45 | 89.2 | 45 | 77 | Q2A-A4089-AAA | |
45 | 91 | 45 | 77 | 55 | 103 | 55 | 96 | Q2A-A4103-AAA | |
55 | 112 | 55 | 96 | 75 | 140 | 75 | 124 | Q2A-A4140-AAA | |
75 | 150 | 75 | 124 | 90 | 168 | 90 | 156 | Q2A-A4168-AAA | |
90 | 180 | 90 | 156 | 110 | 208 | 110 | 180 | Q2A-A4208-AAA | |
110 | 216 | 110 | 180 | 132 | 250 | 150 | 240 | Q2A-A4250-AAA | |
132 | 260 | 150 | 240 | 160 | 296 | 185 | 302 | Q2A-A4296-AAA | |
160 | 304 | 185 | 302 | 200 | 371 | 220 | 361 | Q2A-A4371-AAA | |
200 | 371 | 220 | 361 | 220 | 389 | 260 | 414 | Q2A-A4389-AAA | |
220 | 414 | 260 | 414 | 250 | 453 | 300 | 477 | Q2A-A4453-AAA | |
250 | 453 | 300 | 477 | 315 | 568 | 335 | 515 | Q2A-A4568-AAA | |
315 | 605 | 335 | 515 | 355 | 675 | 370 | 605 | Q2A-A4675-AAA |
① Line filters
200 V | 400 V | ||||||||
---|---|---|---|---|---|---|---|---|---|
Model Q2A-A |
Line filter | Model Q2A-A |
Line filter | ||||||
Filter style | Reference | Current | Quantity | Filter style | Reference | Current | Quantity | ||
2004, 2006 | Footprint type | Q2-FIA4010-SE | 10 A | 1 | 4002 / 4004 / 4005 / 4007 | Footprint type | Q2-FIA4010-SE | 10 A | 1 |
2010, 2012 | Q2-FIA4020-SE | 20 A | 1 | 4009 / 4012 | Q2-FIA4020-SE | 20 A | 1 | ||
2021, 2030 | Q2-FIA4035-SE | 35 A | 1 | 4018 / 4023 | Q2-FIA4035-SE | 35 A | 1 | ||
2042, 2056, 2070 | Book type | Q2-FIA4080-SE | 80 A | 1 | 4031 / 4038 | Q2-FIA4050-SE | 50 A | 1 | |
2082 | Q2-FIA4100-SE | 100 A | 1 | 4044 / 4060 / 4075 | Book type | Q2-FIA4080-SE | 80 A | 1 | |
2110, 2138, 2169 | Q2-FIA4170-SE | 170 A | 1 | 4089 | Q2-FIA4100-SE | 100 A | 1 | ||
2211, 2257, 2313, 2360, 2415 | Busbar -termination type | Q2-FIA4410-SE | 410 A | 1 | 4103 / 4140 / 4168 | Q2-FIA4170-SE | 170 A | 1 | |
– | 4208 / 4250 / 4296 / 4371 / 4389 | Busbar -termination type | Q2-FIA4410-SE | 410 A | 1 | ||||
4453 / 4568 | Q2-FIA4600-SE | 600 A | 1 | ||||||
4675 | Q2-FIA4410-SE | 410 A | 2 |
① Input AC reactors
200 V | 400 V | ||
---|---|---|---|
Model Q2A-A |
Input AC reactor | Model Q2A-A |
Input AC reactor |
2004 / 2006 / 2010 | AX-RAI02800100-DE | 4002 | AX-RAI07700042-DE |
2012 | AX-RAI00880200-DE | 4004 | AX-RAI07700050-DE |
2021 / 2030 / 2042 | AX-RAI00350335-DE | 4005 | AX-RAI03500090-DE |
2056 / 2070 | AX-RAI00180670-DE | 4007 | AX-RAI03500100-DE |
2082 / 2110 | AX-RAI00091000-DE | 4009 / 4012 | AX-RAI01300170-DE |
2138 / 2169 | AX-RAI00071550-DE | 4018 / 4023 / 4031 | AX-RAI00740335-DE |
2211 / 2257 | AX-RAI00042300-DE | 4038 / 4044 | AX-RAI00360500-DE |
2313 / 2360 / 2415 | Please, contact your OMRON representative | 4060 / 4075 | AX-RAI00290780-DE |
4089 / 4103 | AX-RAI00191150-DE | ||
– | 4140 / 4168 | AX-RAI00111850-DE | |
4208 / 4250 | AX-RAI00072700-DE | ||
4296 | AX-RAI00043350-DE | ||
4371 / 4389 | AX-RAI00034500-DE | ||
4453 | AX-RAI00025350-DE |
① DC reactors
200 V | 400 V | ||
---|---|---|---|
Model Q2A-A |
DC reactor | Model Q2A-A |
DC reactor |
2004 / 2006 | AX-RC06750061-DE | 4002 / 4004 | AX-RC43000020-DE |
2010 | AX-RC03510093-DE | 4005 | AX-RC10100069-DE |
2012 | AX-RC02510138-DE | 4007 / 4009 | AX-RC06400116-DE |
2021 / 2030 | AX-RC01110309-DE | 4012 | AX-RC04410167-DE |
2042 | AX-RC00840437-DE | 4018 | AX-RC03350219-DE |
2056 | AX-RC00590614-DE | 4023 | AX-RC02330307-DE |
2070 | AX-RC00440859-DE | 4031 / 4038 | AX-RC01750430-DE |
2082 | AX-RC00301275-DE | 4044 | AX-RC01200644-DE |
① Output AC reactors
200 V | 400 V | ||
---|---|---|---|
Model Q2A-A |
Output AC reactor | Model Q2A-A |
Output AC reactor |
2004 / 2006 | AX-RAO07600042-DE | 4002 | AX-RAO16300038-DE |
2010 | AX-RAO04100075-DE | 4004 | AX-RAO11800053-DE |
2012 | AX-RAO03000105-DE | 4005 | AX-RAO07300080-DE |
2021 / 2030 | AX-RAO01150220-DE | 4007 / 4009 | AX-RAO04600110-DE |
2042 | AX-RAO00950320-DE | 4012 | AX-RAO03600160-DE |
2056 | AX-RAO00630430-DE | 4018 | AX-RAO02500220-DE |
2070 | AX-RAO00490640-DE | 4023 | AX-RAO02000320-DE |
2082 | AX-RAO00390800-DE | 4031 | AX-RAO01650400-DE |
2110 | AX-RAO00330950-DE | 4038 / 4044 | AX-RAO01300480-DE |
2138 | AX-RAO00251210-DE | 4060 | AX-RAO00800750-DE |
2169 | AX-RAO00191450-DE | 4075 | AX-RAO00680900-DE |
2211 | AX-RAO00161820-DE | 4089 / 4103 | AX-RAO00531100-DE |
2257 | AX-RAO00132200-DE | 4140 | AX-RAO00401490-DE |
2313 / 2360 / 2415 | Please, contact your OMRON representative | 4168 | AX-RAO00331760-DE |
4208 | AX-RAO00262170-DE | ||
– | 4250 | AX-RAO00212600-DE | |
4296 | AX-RAO00173250-DE | ||
4371 / 4389 | AX-RAO00134440-DE | ||
4453 | AX-RAO00115250-DE |
This table corresponds with HD rating. When ND is used, please choose the reactor for the next size inverter.
① Chokes
Diameter | Description | Order code |
---|---|---|
21 | For 2.2 KW motors or below | AX-FER2102-PE |
28 | For 15 KW motors or below | AX-FER2815-PE |
50 | For 45 KW motors or below | AX-FER5045-PE |
52 | For 55 KW motors or above | AX-FER5255-PE |
② Option cards
Type | Description | Function | Order code |
---|---|---|---|
Communication option cards |
EtherCAT | Used for running or stopping the inverter, setting or referencing parameters, and monitoring output frequency, output current, or similar items through EtherCAT communication with the host controller. |
SI-ES3 |
PROFINET | Used for running or stopping the inverter, setting or referencing parameters, and monitoring output frequency, output current, or similar items through PROFINET communication with the host controller. |
SI-EP3 | |
EtherNet/IP | Used for running or stopping the inverter, setting or referencing parameters, and monitoring output frequency, output current, or similar items through EtherNet/IP communication with the host controller. |
SI-EN3 | |
EtherNet/IP Dual-Port | SI-EN3/D | ||
POWERLINK | Used for running or stopping the inverter, setting or referencing parameters, and monitoring output frequency, output current, or similar items through POWERLINK communication with the host controller. |
SI-EL3 | |
Input/output option cards |
Analog input | To configure very accurate analog references at high resolution Input signal level: –10 to 10 VDC (20 kW) at 4 to 20 mA (250 W) Input channel: 3 channels (use a DIP switch to select voltage or current input) Voltage input resolution: 13 bits (1/8192) + encoding Current input resolution: 1/4096 |
AI-A3 |
Analog monitor | To use analog signals to monitor the drive output frequency and current Output resolution: 11 bits (1/2048) + encoding Output voltage: –10 to 10 VDC (non-insulated) Output channel: 2 channels |
AO-A3 | |
Digital input | To use digital speed references and MFDI with a maximum 16 bits of resolution Input signals: Binary, 16 bits: BCD4 digits + SIGN signal + SET signal (use parameters to select 6 bits, 8 bits or 12 bits) Input voltage: 24 V (insulated) Input current: 8 mA |
DI-A3 | |
Digital output | To output insulated digital signals and monitor the operation status of the drive (alarm signals and detecting zero speed) Photocoupler relays: 6 channels (48 V, 50 mA max.) Relay contact: 2 channels (250 VAC at 1 A or less, 30 VDC at 1 A or less) |
DO-A3 | |
Feedback speed option cards |
Motor PG feedback open collector interface |
For speed feedback input by connecting a motor encoder Input: 3track (one or two tracks), for HTL encoder connection, 50KHz max Output: 3track, open collector Encoder power supply: 12V, 200mA max |
PG-B3
2
This option card can only be used with
CL-V/f and OLV control methods. |
Motor PG feedback line driver interface |
For speed feedback input by connecting a motor encoder Input: 3 track (one or two tracks), line driver, 300kHz max Output: 3 track, line driver Encoder power supply: 5V or 12V, 200mA max |
PG-X3
2
This option
card can only be used with CLV, CL-V/f and CLV/PM control methods. |
|
EnDat encoder | For speed feedback input by connecting a motor encoder Encoder type: EnDat 2.1/01, EnDat 2.2/01, EnDat 2.2/22 (HEIDENHAIN), HIPERFACE models (SICK STEGMANN) Maximum input frequency: 20 kHz Pulse monitor: Equivalent to RS-422 level Output voltage: 5 V at max. current of 330 mA, 8 V at max. current of 150 mA Wiring length: 20 m max. for the encoder, 30 m max. for the pulse monitor |
PG-F3
2
This option
card can only be used with CLV/PM control method. |
|
Resolver interface | For motor speed feedback by connecting a resolver (TS2640N321E64 by Tamagawa Seiki Co., LTD) Input voltage: 10 VAC rms 10 kHz Transformation ratio: 0.5±5% Maximum input current: 100 mA rms |
PG-RT3
2
This option
card can only be used with CLV and CLV/PM control methods. |
③ Accessories
Description | Functions | Order code | |
---|---|---|---|
LCD remote operator | Standard model | JVOP-KPLCA04AEZ | |
Model with Bluetooth | JVOP-KPLCC04ABZ | ||
USB cable | Mini USB to USB cable | AX-CUSBM002-E | |
Remote operator cable | 3 meters cable to connect the keypad and drive | 3G3AX-CAJOP300-EE | |
Keypad mounting bracket | This bracket is required to mount the LCD Remote Operator outside an enclosure panel |
Screw type | 900-192-933-001 |
Nut type | 900-192-933-002 |
④ Software tools
Description | Functions | Order code |
---|---|---|
Software tools | Software tool to configure drives and manage parameters | Q2edit |
Software tool to do advanced drive programming | Q2dev | |
Software tool to configure drives and manage parameters for mobile devices (Android iOS) |
Q2app |
⑤ D1000 kit - DC Supply with Regenerative Active Front End
Rated power (kW) |
D1000 kit | |||
---|---|---|---|---|
Regenerative DC bus supplyunit (D1000)
2
It is not possible to purchase the Regenerative DC bus supply unit (D1000), EMC filter and low harmonic filter as a separate items. |
EMC filter
2
It is not possible to purchase the Regenerative DC bus supply unit (D1000), EMC filter and low harmonic filter as a separate items. |
Low harmonic filter
2
It is not possible to purchase the Regenerative DC bus supply unit (D1000), EMC filter and low harmonic filter as a separate items. |
Kit code | |
5 | CIMR-DC4A0005BAA | B84143A0020R106 | B84143G0008R176 | D1KIT40005AAAAB |
10 | CIMR-DC4A0010BAA | B84143G0016R176 | D1KIT40010AAAAB | |
20 | CIMR-DC4A0020BAA | B84143A0035R106 | B84143G0030R176 | D1KIT40020AAAAB |
30 | CIMR-DC4A0030AAA | B84143A0065R106 | B84143G0043R176 | D1KIT40030AAAAB |
40 | CIMR-DC4A0040AAA | B84143G0058R176 | D1KIT40040AAAAB | |
60 | CIMR-DC4A0060AAA | B84143B0180S080 | B84143G0086R176 | D1KIT40060AAAAB |
100 | CIMR-DC4A0100AAA | B84143G0145R176 | D1KIT40100AAAAB | |
130 | CIMR-DC4A0130AAA | B84143B0400S080 | B84143G0210S176 | D1KIT40130AAAAB |
185 | CIMR-DC4A0185AAA | B84143G0300S176 | D1KIT40185AAAAB | |
270 | CIMR-DC4A0270AAA | B84143B1000S080 | B84143G0410S176 | D1KIT40270AAAAB |
370 | CIMR-DC4A0370AAA | B84143G0560S176 | D1KIT40370AAAAB |
⑤ R1000 kit - Regenerative Braking unit
Rated power (kW) |
R1000 kit | ||
---|---|---|---|
Regenerative braking unit (R1000)
2
It is not possible to purchase the Regenerative
braking unit (R1000) and current suppression reactor as a separate
items. |
Current suppression reactor (1%)
2
It is not possible to purchase the Regenerative
braking unit (R1000) and current suppression reactor as a separate
items. |
Kit code | |
3.5 | CIMR-RC4A03P5FAA | B1509105 | R1KIT40003AAAAA |
5 | CIMR-RC4A0005FAA | R1KIT40005AAAAA | |
7 | CIMR-RC4A0007FAA | B1509106 | R1KIT40007AAAAA |
10 | CIMR-RC4A0010FAA | B1509107 | R1KIT40010AAAAA |
14 | CIMR-RC4A0014FAA | B1509108 | R1KIT40014AAAAA |
17 | CIMR-RC4A0017FAA | R1KIT40017AAAAA | |
20 | CIMR-RC4A0020FAA | B1509109 | R1KIT40020AAAAA |
28 | CIMR-RC4A0028FAA | B1509110 | R1KIT40028AAAAA |
35 | CIMR-RC4A0035AAA | B1504118 | R1KIT40035AAAAA |
43 | CIMR-RC4A0043AAA | B1509111 | R1KIT40043AAAAA |
53 | CIMR-RC4A0053AAA | B1509112 | R1KIT40053AAAAA |
73 | CIMR-RC4A0073AAA | B1509113 | R1KIT40073AAAAA |
105 | CIMR-RC4A0105AAA | B1509114 | R1KIT40105AAAAA |
150 | CIMR-RC4A0150AAA | B1505002 | R1KIT40150AAAAA |
210 | CIMR-RC4A0210AAA | B1505008 | R1KIT40210AAAAA |
300 | CIMR-RC4A0300AAA | B1505011 | R1KIT40300AAAAA |
⑤ Braking unit, braking resistor unit
Inverter | Braking unit | Braking Resistor (10% ED) | Connectable min. resistance Ω |
||||||
---|---|---|---|---|---|---|---|---|---|
Max. applicable motor kW |
Model Q2A-A |
Model | Qty | Model | Specifications of Resistor | Qty | |||
200 V class |
0.4 | 2004 HD | Built-in | AX-REM00K1200-IE | 100W | 200 Ω | 1 | 48 | |
0.75 | 2004 ND | ||||||||
2006 HD | |||||||||
1.5 | 2006 ND | AX-REM00K4075-IE | 400W | 75 Ω | 1 | ||||
2010 HD | |||||||||
2.2 | 2010 ND | ||||||||
2012 HD | 16 | ||||||||
3.0 | 2012 ND | AX-REM00K4035-IE | 400W | 35 Ω | 1 | ||||
3.7 | 2021 HD | ||||||||
5.5 | 2021 ND | AX-REM00K6035-IE | 600W | 35 Ω | 1 | ||||
2030 HD | |||||||||
7.5 | 2030 ND | AX-REM00K9020-IE | 900W | 20 Ω | 1 | ||||
2042 HD | 9.6 | ||||||||
11 | 2042 ND | AX-REM02K1017-IE | 2000W | 17 Ω | 1 | ||||
2056 HD | |||||||||
15 | 2056 ND | AX-REM03K5010-IE | 3500W | 10 Ω | 1 | ||||
2070 HD | |||||||||
18.5 | 2070 ND | ||||||||
2082 HD | |||||||||
22 | 2082 ND | ||||||||
2110 HD | AX-REM19K0008-IE | 19000W | 8 Ω | 1 | 6.4 | ||||
30 | 2110 ND | ||||||||
2138 HD | |||||||||
37 | 2138 ND | ||||||||
2169 HD | CDBR-2037D | 1 | AX-REM19K0006-IE | 19000W | 6 Ω | 1 | 5.0 | ||
45 | 2169 ND | ||||||||
2211 HD | CDBR-2022D | 2 | AX-REM19K0008-IE | 19000W | 8 Ω | 2 | 6.4 | ||
55 | 2211 ND | ||||||||
2257 HD | |||||||||
75 | 2257 ND | CDBR-2110D | 1 | Please, contact your OMRON representative | |||||
2313 HD | |||||||||
90 | 2313 ND | ||||||||
2360 HD | |||||||||
110 | 2360 ND | ||||||||
2415 HD | |||||||||
400 V class | 0.4 | 4002 HD | Built-in | AX-REM00K1400-IE | 100 W | 400 Ω | 1 | 165 | |
0.75 | 4002 ND | ||||||||
4004 HD | |||||||||
1.5 | 4004 ND | AX-REM00K2200-IE | 200 W | 200 Ω | 1 | ||||
4005 HD | 110 | ||||||||
2.2 | 4005 ND | ||||||||
4007 HD | |||||||||
3.0 | 4007 ND | ||||||||
4009 HD | AX-REM00K4075-IE | 400 W | 75 Ω | 1 | 55 | ||||
3.7 | 4009 ND | ||||||||
4012 HD | |||||||||
5.5 | 4012 ND | AX-REM00K5120-IE | 500 W | 120 Ω | 1 | ||||
4018 HD | 32 | ||||||||
7.5 | 4018 ND | AX-REM00K9070-IE | 900 W | 70 Ω | 1 | ||||
4023 HD | |||||||||
11 | 4023 ND | ||||||||
4031 HD | 20 | ||||||||
15 | 4031 ND | AX-REM01K9070-IE | 1900 W | 70 Ω | 1 | ||||
4038 HD | |||||||||
18.5 | 4038 ND | AX-REM03K5035-IE | 3500 W | 35 Ω | 1 | ||||
4044 HD | 19.2 | ||||||||
22 | 4044 ND | ||||||||
4060 HD | |||||||||
30 | 4060 ND | AX-REM19K0030-IE | 19000 W | 30 Ω | 1 | ||||
4075 HD | |||||||||
37 | 4075 ND | ||||||||
4089 HD | 2 | 10.6 | |||||||
45 | 4089 ND | ||||||||
4103 HD | 8.7 | ||||||||
55 | 4103 ND | ||||||||
4140 HD | AX-REM38K0012-IE | 38000 W | 12 Ω | 1 | 7.2 | ||||
75 | 4140 ND | ||||||||
4168 HD | AX-REM19K0020-IE | 19000 W | 20 Ω | 3 | 5.2 | ||||
90 | 4168 ND | ||||||||
4208 HD | CDBR-4045D | 2 | 12.8 | ||||||
110 | 4208 ND | CDBR-4220D | 1 | 4 | 3.2 | ||||
4250 HD | |||||||||
132 | 4250 ND | AX-REM38K0012-IE | 38000 W | 12 Ω | 2 | 3.2 | |||
4296 HD | |||||||||
160 | 4296 ND | ||||||||
4371 HD | |||||||||
200 | 4371 ND | ||||||||
4389 HD | |||||||||
220 | 4389 ND | Please, contact your OMRON representative | |||||||
4453 HD | |||||||||
250 | 4453 ND | ||||||||
4568 HD | |||||||||
315 | 4568 ND | 2 | |||||||
4675 HD | |||||||||
355 | 4675 ND |
Specifications
200 V class
Q2A-A |
Duty rating |
2004 | 2006 | 2010 | 2012 | 2021 | 2030 | 2042 | 2056 | 2070 | |
---|---|---|---|---|---|---|---|---|---|---|---|
Max. applicable motor output (kW) | HD
2
The
maximum applicable motor output complies with 208 V motor ratings
as specified in NEC Table 430.250. The rated output current of the
drive output amps must be equal to or more than the motor rated
current. |
0.55 | 0.75 | 1.5 | 2.2 | 4.0 | 5.5 | 7.5 | 11 | 15 | |
ND
2
The
maximum applicable motor output is based on 4-pole, general-purpose
220 V motor ratings. The rated output current of the drive output
amps must be equal to or more than the motor rated current. |
0.75 | 1.1 | 2.2 | 3.0 | 5.5 | 7.5 | 11 | 15 | 18.5 | ||
Output characteristics |
Inverter capacity (kVA) | HD
2
The
rated output capacity is calculated with a rated output voltage
of 208 V. |
1.2 | 1.9 | 3.0 | 4.2 | 6.7 | 9.5 | 12.6 | 17.9 | 22.9 |
ND
2
The
rated output capacity is calculated with a rated output voltage
of 220 V. |
1.3 | 2.3 | 3.7 | 4.6 | 8.0 | 11.4 | 16 | 21.3 | 26.7 | ||
Rated output current (A) | HD | 3.2 | 5.0 | 8.0 | 11 | 17.5 | 25 | 33 | 47 | 60 | |
ND | 3.5 | 6.0 | 9.6 | 12.2 | 21 | 30 | 42 | 56 | 70 | ||
Overload
tolerance
2
Derating may be necessary for
applications that start and stop frequently. |
HD: 150% of the rated output current for 60 seconds ND: 110% of the rated output current for 60 seconds |
||||||||||
Carrier frequency
2
Derate the drive capacity to use values to 15 kHz maximum (2004 to 2138 models) or 10 kHz maximum (2169 to 2415 models). (without derating the drive capacity) |
HD: 8 kHz ND: 2 kHz |
||||||||||
Max. output voltage | Proportional to input voltage: 200-240 V | ||||||||||
Max. output frequency | AOLV, EZOLV: 120 Hz CL-V/f, CLV, AOLV/PM, CLV/PM: 400 Hz V/f, OLV, OLV/PM: 590 Hz |
||||||||||
Power supply | Rated voltage and frequency | 3-phase AC power supply 200-240 V at 50/60 Hz DC power supply 270-340 VDC |
|||||||||
Allowable voltage fluctuation | –15% to +10% | ||||||||||
Allowable frequency fluctuation | ±5% | ||||||||||
Input Power (kVA) | HD | 1.5 | 2.0 | 3.7 | 5.3 | 8.6 | 12.5 | 16.8 | 24.2 | 32.6 | |
ND | 2.0 | 2.8 | 5.3 | 7.1 | 12.5 | 16.8 | 21.6 | 32.6 | 39.9 | ||
Weight (kg) | 3.5 | 3.9 | 4.2 | 6 | 8.5 |
Q2A-A |
Duty rating |
2082 | 2110 | 2138 | 2169 | 2211 | 2257 | 2313 | 2360 | 2415 | |
---|---|---|---|---|---|---|---|---|---|---|---|
Max. applicable motor output (kW) | HD
2
The
maximum applicable motor output complies with 208 V motor ratings
as specified in NEC Table 430.250. The rated output current of the
drive output amps must be equal to or more than the motor rated
current. |
18.5 | 22 | 30 | 37 | 45 | 55 | 75 | 90 | 110 | |
ND
2
The
maximum applicable motor output is based on 4-pole, general-purpose
220 V motor ratings. The rated output current of the drive output
amps must be equal to or more than the motor rated current. |
22 | 30 | 37 | 45 | 55 | 75 | 90 | 110 | – | ||
Output characteristics |
Inverter capacity (kVA) | HD
2
The
rated output capacity is calculated with a rated output voltage
of 208 V. |
28.6 | 33.5 | 43.8 | 55.3 | 68.6 | 81.9 | 108 | 132 | 158 |
ND
2
The
rated output capacity is calculated with a rated output voltage
of 220 V. |
31.2 | 41.9 | 52.6 | 64.4 | 80.4 | 97.9 | 119 | 137 | – | ||
Rated output current (A) | HD | 75 | 88 | 115 | 145 | 180 | 215 | 283 | 346 | 415 | |
ND | 82 | 110 | 138 | 169 | 211 | 257 | 313 | 360 | – | ||
Overload
tolerance
2
Derating may be necessary for
applications that start and stop frequently. |
HD: 150% of the rated output current for 60 seconds ND: 110% of the rated output current for 60 seconds |
||||||||||
Carrier frequency
2
Derate the drive capacity to use values to 15 kHz maximum (2004 to 2138 models) or 10 kHz maximum (2169 to 2415 models). (without derating the drive capacity) |
HD: 8 kHz ND: 2 kHz |
HD: 5 kHz ND: 2 kHz |
|||||||||
Max. output voltage | Proportional to input voltage: 200-240 V | ||||||||||
Max. output frequency | AOLV, EZOLV: 120 Hz CL-V/f, CLV, AOLV/PM, CLV/PM: 400 Hz V/f, OLV, OLV/PM: 590 Hz |
||||||||||
Power supply | Rated voltage and frequency | 3-phase AC power supply 200-240 V at 50/60 Hz DC power supply 270-340 VDC |
|||||||||
Allowable voltage fluctuation | –15% to +10% | ||||||||||
Allowable frequency fluctuation | ±5% | ||||||||||
Input Power (kVA) | HD | 39.9 | 34.1 | 46.1 | 56.5 | 68.2 | 83.1 | 113 | 135 | 164 | |
ND | 47.4 | 46.1 | 56.5 | 68.2 | 83.1 | 113 | 135 | 164 | – | ||
Weight (kg) | 9.0 | 22 | 24 | 39 | 40 | 67 | 104 | 119 |
400 V class
Q2A-A |
Input voltage |
Duty rating |
4002 | 4004 | 4005 | 4007 | 4009 | 4012 | 4018 | 4023 | 4031 | 4038 | 4044 | 4060 | 4075 | |
---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
Max. applicable motor output (kW) | < 460
V
2
The maximum applicable motor output complies
with 380 V motor ratings as specified in Annex G of IEC 60947-4-1.
The rated output current of the drive output amps must be equal
to or more than the motor rated current. |
HD | 0.55 | 0.75 | 1.5 | 2.2 | 3.0 | 3.7 | 5.5 | 7.5 | 11 | 15 | 18.5 | 22 | 30 | |
ND | 0.75 | 1.5 | 2.2 | 3.0 | 3.7 | 5.5 | 7.5 | 11 | 15 | 18.5 | 22 | 30 | 37 | |||
≥ 460 V
2
The maximum applicable motor output complies
with 460 V motor ratings as specified in NEC Table 430.250. The
rated output current of the drive output amps must be equal to or
more than the motor rated current. |
HD | 0.55 | 0.75 | 1.5 | 2.2 | 3.0 | 3.7 | 5.5 | 7.5 | 11 | 15 | 18.5 | 22 | 30 | ||
ND | 0.75 | 1.5 | 2.2 | 3.0 | 3.7 | 5.5 | 7.5 | 11 | 15 | 18.5 | 22 | 30 | 37 | |||
Output characteristics |
Inverter capacity (kVA) | < 460
V
2
The rated output capacity is calculated
with a rated output voltage of 380 V. |
HD | 1.2 | 2.2 | 3.2 | 3.6 | 4.7 | 6.1 | 10 | 12 | 16 | 20 | 26 | 30 | 39 |
ND | 1.4 | 2.7 | 3.6 | 4.7 | 5.9 | 7.8 | 12 | 15 | 20 | 25 | 29 | 39 | 49 | |||
≥ 460 V
2
The rated output capacity is calculated
with a rated output voltage of 460 V. |
HD | 1.3 | 1.7 | 2.7 | 3.8 | 5.5 | 6.1 | 8.8 | 11 | 17 | 22 | 27 | 32 | 41 | ||
ND | 1.7 | 2.4 | 3.8 | 5.5 | 6.1 | 8.8 | 11 | 17 | 22 | 27 | 32 | 41 | 52 | |||
Rated output current (A) | < 460 V | HD | 1.8 | 3.4 | 4.8 | 5.5 | 7.2 | 9.2 | 14.8 | 18 | 24 | 31 | 39 | 45 | 60 | |
ND | 2.1 | 4.1 | 5.4 | 7.1 | 8.9 | 11.9 | 17.5 | 23.4 | 31 | 38 | 44 | 59.6 | 74.9 | |||
≥ 460 V | HD | 1.6 | 2.1 | 3.4 | 4.8 | 6.9 | 7.6 | 11 | 14 | 21 | 27 | 34 | 40 | 52 | ||
ND | 2.1 | 3.0 | 4.8 | 6.9 | 7.6 | 11 | 14 | 21 | 27 | 34 | 40 | 52 | 65 | |||
Overload
tolerance
2
Derating may be necessary for
applications that start and stop frequently. |
HD: 150% of the rated output current for 60 seconds ND: 110% of the rated output current for 60 seconds |
|||||||||||||||
Carrier frequency
2
Derate the drive capacity to use values to 15 kHz maximum (4002 to 4103 models), 10 kHz maximum (4140 to 4389 models) or 5 kHz maximum (4453 to 4675 models). (without derating the drive capacity) |
HD: 8 kHz ND: 2 kHz |
|||||||||||||||
Max. output voltage | Proportional to input voltage: 380-480 V | |||||||||||||||
Max. output frequency | AOLV, EZOLV: 120 Hz CL-V/f, CLV, AOLV/PM, CLV/PM: 400 Hz V/f, OLV, OLV/PM: 590 Hz |
|||||||||||||||
Power supply | Rated voltage and frequency | 3-phase AC power supply 380-480 V at 50/60 Hz DC power supply 513-679 VDC |
||||||||||||||
Allowable voltage fluctuation | –15% to +10% | |||||||||||||||
Allowable frequency fluctuation | ±5% | |||||||||||||||
Input Power (kVA) | < 460 V | HD | 1.5 | 2.8 | 3.7 | 5.3 | 7.1 | 9.3 | 13 | 17 | 24 | 33 | 40 | 34 | 46 | |
ND | 2.0 | 3.7 | 5.3 | 7.1 | 9.3 | 13 | 17 | 24 | 33 | 40 | 48 | 46 | 57 | |||
≥ 460 V | HD | 1.3 | 1.7 | 3.2 | 4.6 | 6.1 | 7.5 | 11 | 15 | 21 | 28 | 35 | 30 | 40 | ||
ND | 2.1 | 4.0 | 5.6 | 7.5 | 9.1 | 13 | 18 | 26 | 35 | 42 | 50 | 49 | 60 | |||
Weight (kg) | 3.5 | 3.9 | 4.2 | 6.0 | 7.5 | 12 | 17 |
Q2A-A |
Input voltage |
Duty rating |
4089 | 4103 | 4140 | 4168 | 4208 | 4250 | 4296 | 4371 | 4389 | 4453 | 4568 | 4675 | |
---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
Max. applicable motor output (kW) | < 460
V
2
The maximum applicable motor output complies
with 380 V motor ratings as specified in Annex G of IEC 60947-4-1.
The rated output current of the drive output amps must be equal
to or more than the motor rated current. |
HD | 37 | 45 | 55 | 75 | 90 | 110 | 132 | 160 | 200 | 220 | 250 | 315 | |
ND | 45 | 55 | 75 | 90 | 110 | 132 | 160 | 200 | 220 | 250 | 315 | 355 | |||
≥ 460 V
2
The maximum applicable motor output complies
with 460 V motor ratings as specified in NEC Table 430.250. The
rated output current of the drive output amps must be equal to or
more than the motor rated current. |
HD | 37 | 45 | 55 | 75 | 90 | 110 | 150 | 185 | 220 | 260 | 300 | 335 | ||
ND | 45 | 55 | 75 | 90 | 110 | 150 | 185 | 220 | 260 | 300 | 335 | 370 | |||
Output characteristics |
Inverter capacity (kVA) | < 460
V
2
The rated output capacity is calculated
with a rated output voltage of 380 V. |
HD | 49 | 60 | 74 | 99 | 118 | 142 | 171 | 200 | 244 | 272 | 298 | 398 |
ND | 59 | 68 | 92 | 111 | 137 | 165 | 195 | 244 | 256 | 298 | 374 | 444 | |||
≥ 460 V
2
The rated output capacity is calculated
with a rated output voltage of 460 V. |
HD | 52 | 61 | 76 | 99 | 124 | 143 | 191 | 241 | 288 | 330 | 380 | 410 | ||
ND | 61 | 76 | 99 | 124 | 143 | 191 | 241 | 288 | 330 | 380 | 410 | 482 | |||
Rated output current (A) | < 460 V | HD | 75 | 91 | 112 | 150 | 180 | 216 | 260 | 304 | 371 | 414 | 453 | 605 | |
ND | 89.2 | 103 | 140 | 168 | 208 | 250 | 296 | 371 | 389 | 453 | 568 | 675 | |||
≥ 460 V | HD | 65 | 77 | 96 | 124 | 156 | 180 | 240 | 302 | 361 | 414 | 477 | 515 | ||
ND | 77 | 96 | 124 | 156 | 180 | 240 | 302 | 361 | 414 | 477 | 515 | 605 | |||
Overload
tolerance
2
Derating may be necessary for
applications that start and stop frequently. |
HD: 150% of the rated output current for 60 seconds ND: 110% of the rated output current for 60 seconds |
||||||||||||||
Carrier frequency
2
Derate the drive capacity to use values to 15 kHz maximum (4002 to 4103 models), 10 kHz maximum (4140 to 4389 models) or 5 kHz maximum (4453 to 4675 models). (without derating the drive capacity) |
HD: 8 kHz ND: 2 kHz |
HD: 5 kHz ND: 2 kHz |
HD: 2 kHz ND: 2 kHz |
||||||||||||
Max. output voltage | Proportional to input voltage: 380-480 V | ||||||||||||||
Max. output frequency | AOLV, EZOLV: 120 Hz CL-V/f, CLV, AOLV/PM, CLV/PM: 400 Hz V/f, OLV, OLV/PM: 590 Hz |
||||||||||||||
Power supply | Rated voltage and frequency | 3-phase AC power supply 380-480 V at 50/60 Hz DC power supply 513-679 VDC |
|||||||||||||
Allowable voltage fluctuation | –15% to +10% | ||||||||||||||
Allowable frequency fluctuation | ±5% | ||||||||||||||
Input Power (kVA) | < 460 V | HD | 57 | 69 | 84 | 113 | 136 | 165 | 198 | 239 | 297 | 327 | 370 | 465 | |
ND | 69 | 84 | 113 | 136 | 165 | 198 | 239 | 297 | 327 | 370 | 465 | 523 | |||
≥ 460 V | HD | 49 | 59 | 72 | 98 | 117 | 142 | 193 | 240 | 288 | 335 | 382 | 429 | ||
ND | 73 | 88 | 120 | 143 | 174 | 236 | 295 | 352 | 410 | 468 | 526 | 584 | |||
Weight (kg) | 22 | 25 | 38 | 39 | 71 | 122 | 126 | 198 | 207 |
Dimensions
Voltage class | Inverter model Q2A-A_ |
Dimensions in mm | |||
---|---|---|---|---|---|
H | W | D | |||
Three-phase 200 V | 2004, 2006, 2010, 2012 | 260 | 140 | 176 | |
2021, 2030, 2042 | 211 | ||||
2056 | 300 | 180 | 202 | ||
2070, 2082 | 350 | 220 | 227 | ||
2110 | 400 | 240 | 280 | ||
2138 | 450 | 255 | |||
2169, 2211 | 543 | 264 | 335 | ||
2257, 2313 | 700 | 312 | 420 | ||
2360, 2415 | 800 | 440 | 472 | ||
Three-phase 400 V | 4002, 4004, 4005 | 260 | 140 | 176 | |
4007, 4009, 4012, 4018, 4023 | 211 | ||||
4031, 4038 | 300 | 180 | 202 | ||
4044 | 350 | 220 | 227 | ||
4060 | 246 | ||||
4075 | 400 | 240 | 280 | ||
4089, 4103 | 450 | 255 | |||
4140, 4168 | 543 | 264 | 335 | ||
4208, 4250, 4296 | 700 | 312 | 420 | ||
4371, 4389 | 800 | 440 | 472 |
How can we help you?
If you have a question or would like to ask for a quote, please contact us or send a request.
Contact me Q2A
Thank you for submitting your request. We will come back to you as soon as possible.
We are experiencing technical difficulties. Your form submission has not been successful. Please accept our apologies and try again later. Details: [details]
DownloadQuotation for Q2A
By completing this form you can request a quotation. Your personal details will be handled confidentially.
Thank you for requesting a quotation. We will provide you with the required information as soon as possible.
We are experiencing technical difficulties. Your form submission has not been successful. Please accept our apologies and try again later. Details: [details]
DownloadFeatures
Improved motor performance
- Q2A series is able to control different motor types in open and closed loops.
- Up to 590 Hz as standard.
- Zero speed control without encoder.
- Tuning-less with EZ vector.
- Advanced motor control for IM, PM & SynRM motors.
Cost effective network integration
Up to 5 Q2A with a single communication option card.
PC configuration tools: Q2edit and Q2dev
Optimize your engineering time. Graphic Development Environment provides faster application customization. Graphical setup: Q2 edit software tool provides parameter setting and monitoring for computers and smart devices.
Program >> Deploy >> Go
Q2A drive series can be programmed without any power supply connected. Simply plug into one of your PC’s USB ports, start programming and enjoy the ease of commissioning.
Q2app
Q2app
- Q2app allow you to connect to your Q2 series drives via Bluetooth or mini USB connection (only for Android devices).
- Q2A & Q2V inverters are supported.
- Drive status screen shows main indicators like motor speed, frequency reference, output frequency, output current, drive status, digital inputs and outputs status for a quick drive diagnosis.
- Any parameter can be changed and thanks to chart diagram visualization you can trace any parameter or monitor evolution over time.
- Hardware information can be checked as inverter family, model, serial number and firmware version, even if the ID label is not accessible.
Apple store Q2app
Scan to go directly to the Apple store to download the Q2app. Compatible with iPhone, iPad and iPod Touch.
Google Play store Q2app
Scan to go directly to the Google Play store to download the Q2app. Compatible with Android devices.