DST-MD

Features

DeviceNet safety I/O terminal block family

The DeviceNet safety I/O-terminal DST-MD has 8 inputs for safety signals and eight solid-state safety outputs with up to 500mA. Four test pulse outputs ensure crosstalk and short-circuit detection of the inputs.

  • Removable cage-clamp terminals for easy installation
  • 8 inputs for safety signals
  • 4 test pulse outputs to ensure crosstalk and short-circuit detection
  • 8 solid-state outputs
  • Status LEDs for advanced diagnostics
Specifications & ordering info

Ordering information

 

 

Appearance

Appearance description

Order code

Input terminal

12 PNP inputs

4 Test outputs

Removable cage clamp terminals

DST1-ID12SL-1

Mixed I/O terminal

8 PNP inputs

8 PNP outputs

4 Test outputs

Removable cage clamp terminals

DST1-MD16SL-1

Mixed I/O terminal

4 PNP inputs

4 relay outputs (4×2-single pole)

4 Test outputs

Removable cage clamp terminals

DST1-MRD08SL-1

Specifications

General specifications

DeviceNet communications power supply voltage

11 to 25 VDC
(supplied from communications connector)

Unit power supply voltage

20.4 to 26.4 VDC (24 VDC -15% +10%)

I/O power supply voltage

Consumption
current

Communications power supply

DST1-ID12SL-1/MD16SL-1: 100 mA

DST1-MRD08SL-1: 110 mA

Mounting method

35-mm DIN track

Ambient operating temperature

-10°C +55°C

Ambient storage temperature

-40°C +70°C

Degree of protection

IP20 (IEC 60529)

Weight

DST1-ID12SL-1/MD16SL-1: 420 g

DST1-MRD08SL-1: 600 g

Safety input specifications

Input type

Sinking inputs (PNP)

ON voltage

11 VDC min. between each input terminal and G1

OFF voltage

5 VDC max. between each input terminal and G1

OFF current

1 mA max.

Input current

6 mA

Safety output specifications

Output type

Sourcing outputs (PNP)

Rated output current

0.5 A max. per output

Residual voltage

1.2 V max. between each output terminal and V1

Test output specifications

Output type

Sourcing outputs (PNP)

Rated output current

0.7 A max. per point

Residual voltage

1.2 V max. between each output terminal and V0

Safety output specifications for relay outputs

Relays

G7SA-2A2B, EN 50205 class A

Minimum applicable load

1 mA at 5 VDC

Rated load for a resistive load

240 VAC: 2 A, 30 VDC: 2 A

Rated load for an inductive load

2 A at 240 VAC (cos φ = 0.3),

1 A at 24 VDC

Mechanical life expectancy

5,000,000 operations min.
(switching frequency of 7,200 operations/h)

Electrical life expectancy

100,000 operations min. (at rated load and
switching frequency of 1,800 operations/h)

 

Safety I/O terminals

DST1-ID12SL-1

DST1-MD16SL-1

DST1-MRD08SL-1

 

Have a question?

We are ready to help.

Contact us

Subscribe to product updates

Newsletters about product innovations, solutions and services, directly in your inbox.

Thank you for subscribing to Omron's eNews. You will shortly receive an e-mail from us. This e-mail contains a link which activates your email newsletter subscription. This method is used due to legal issues and to make certain that no-one can abuse your e-mail address.

We are experiencing technical difficulties. Your form submission has not been successful. Please accept our apologies and try again later. Details: [details]

Download

Product documentation

Download datasheets, manuals and brochures.

Browse download center

Training courses

Get the training from our best engineers. Beginner to advanced level.

View training courses