Login

We are experiencing technical difficulties. Your form submission has not been successful. Please accept our apologies and try again later. Details: [details]

Download

Register

We are experiencing technical difficulties. Your form submission has not been successful. Please accept our apologies and try again later. Details: [details]

Download

Thank you for registering

An email to complete your account has been sent to

Return to the website

get direct access

Fill in your details below and get direct access to content on this page

Text error notification

Text error notification

Checkbox error notification

Checkbox error notification

We are experiencing technical difficulties. Your form submission has not been successful. Please accept our apologies and try again later. Details: [details]

Download

Thank you for your interest

You now have access to V680/V680S

A confirmation email has been sent to

Continue to page

Please or get direct access to download this document

V680/V680S

V680/V680S

3 in 1 RFID system: Antenna, Amplifier & Controller in a single compact housing

The all-in-one design of the V680S RFID system provides simple installation. Communication via a Modbus TCP connection, ideal for industrial applications, makes system expansion possible with minimal effort. Configuration via the integrated web browser interface is fast and requires no additional software or special cables.

  • Ethernet (Modbus TCP)
  • WEB browser can be used for setting, monitoring, and communications with RFID tags
  • RFID Analyser
  • Communication Diagnostic

Specifications & ordering info

Ordering information

V680S-series

RF tag

Type Memory capacity Appearance Size Installation Order code
Battery-less 2 kbytes 40 × 40 × 5 mm For flush mounting on metallic surface V680S-D2KF67M
For flush mounting on nonmetallic surface V680S-D2KF67
86 × 54 × 10 mm For flush mounting on metallic surface V680S-D2KF68M
For flush mounting on nonmetallic surface V680S-D2KF68
8 kbytes 40 × 40 × 5 mm For flush mounting on metallic surface V680S-D8KF67M
2
V680S-D8KF6_M/V680S-D8KF6_ can be used with V680S series Reader/Writer version 2.00 or higher.
For flush mounting on nonmetallic surface V680S-D8KF67
2
V680S-D8KF6_M/V680S-D8KF6_ can be used with V680S series Reader/Writer version 2.00 or higher.
86 × 54 × 10 mm For flush mounting on metallic surface V680S-D8KF68M
2
V680S-D8KF6_M/V680S-D8KF6_ can be used with V680S series Reader/Writer version 2.00 or higher.
For flush mounting on nonmetallic surface V680S-D8KF68
2
V680S-D8KF6_M/V680S-D8KF6_ can be used with V680S series Reader/Writer version 2.00 or higher.

V680-series

RF tag

Type Memory capacity Appearance Size Installation Order code
Battery-less 1 kbyte 20 dia. × 2.7 mm For flush mounting on nonmetallic surface V680-D1KP54T
34 × 34 × 3.5 mm For flush mounting on metallic surface V680-D1KP66MT
For flush mounting on nonmetallic surface V680-D1KP66T
Environment-resistant type
Battery-less
95 × 36.5 × 6.5 mm For flush mounting on nonmetallic surface V680-D1KP66T-SP
High-temperature type
Battery-less
80 dia. × t10 mm For mounting with special attachment V680-D1KP58HTN
Note:

V680 series 8kbyte RF Tag (V680-D8KF67,V680-D8KF67M and V680-D8KF68A) can communicate with V680S series Reader/Writer. For details, refer to the User's Manual (Cat. No. Z339).

Reader/Writer

Type Appearance Size Network Order code
Reader/Writer 50 × 50 × 30 mm EtherNet/IP V680S-HMD63-EIP
PROFINET V680S-HMD63-PNT
75 × 75 × 40 mm EtherNet/IP V680S-HMD64-EIP
PROFINET V680S-HMD64-PNT
120 × 120 × 40 mm EtherNet/IP V680S-HMD66-EIP
PROFINET V680S-HMD66-PNT
50 × 50 × 30 mm Modbus TCP (TCP/IP) V680S-HMD63-ETN
75 × 75 × 40 mm V680S-HMD64-ETN
120 × 120 × 40 mm V680S-HMD66-ETN

RF tag attachment

Type Appearance Order code
For the V680-D1KP66T V600-A86
For the V680-D1KP58HTN V680-A80
For the V680-D1KP54T V700-A80

Cable

Type Appearance Length Order code
Special connector – RJ45 2 m V680S-A41 2M
5 m V680S-A41 5M
10 m V680S-A41 10M
Special connector – Loose wires 2 m V680S-A42 2M
5 m V680S-A42 5M
10 m V680S-A42 10M

Extension cable

Type Appearance Length Order code
Special connector – Special connector 10 m V680S-A40 10M
20 m V680S-A40 20M
50 m V680S-A40 50M
Note:

The maximum extendable cable length using the cable and extension cable is 60 m. Only one extension cable can be used.

Industrial switching hubs (Recommended hubs)

Type Appearance Specifications Order code
Functions No. of ports Failure detection
Industrial switching hubs
Quality of Service (QoS): 
EtherNet/IP control data priority
Failure detection: 
Broadcast storm and LSI error detection 
10/100BASE-TX, Auto-Negotiation
3 No W4S1-03B
5 No W4S1-05B
5 Yes W4S1-05C

RFID Units

RFID Units Appearance Product name Amplifier/Antenna No. of unit
numbers used
Order code
NX-series RFID Units RFID Units V680 series 1 NX-V680C1
2 NX-V680C2

Specifications

V680S-series

RF tag (2-kbyte Memory)

Item V680S-D2KF67 V680S-D2KF67M V680S-D2KF68 V680S-D2KF68M
Memory capacity 2,000bytes (user area)
Memory type FRAM
Data retention 10 years after writing (85°C or less)
Memory life One trillion writes for each block (85°C or less), Access frequency
2
The number of accesses is the total number of reads and writes.
: One trillion accesses
Ambient operating temperature −20 to 85°C (with no icing)
Ambient storage temperature −40 to 125°C (with no icing)
Ambient operating humidity 35% to 85%
Degree of protection IP68 (IEC 60529:2001), Oil resistance equivalent to IP67G (JIS C 0920:2003, Appendix 1)
2
Oil resistance has been tested using a specific oil as defined in the OMRON test method.
.
IPX9K (DIN 40 050)
Vibration resistance No abnormality after application of 10 to 2,000 Hz, 1.5-mm double amplitude, acceleration: 150 m/s², 10 sweeps each in X, Y, and Z directions for 15 minutes each No abnormality after application of 10 to 500 Hz, 1.5-mm double amplitude, acceleration: 100 m/s², 10 sweeps each in X, Y, and Z directions for 11 minutes each
Shock resistance No abnormality after application of 500 m/s², 3 times each in X, Y, and Z directions (Total: 18 times)
Dimensions (W×H×D) 40 × 40 × 5 mm 86 × 54 × 10 mm
Materials Exterior: PPS resin
Weight Approx. 11.5 g Approx. 12 g Approx. 44 g Approx. 46 g
Metal countermeasures None Provided None Provided
Note:

For details, refer to the User’s Manual (Cat. No. Z339).

RF Tag (8-kbyte Memory)

Item V680S-D8KF67 V680S-D8KF67M V680S-D8KF68 V680S-D8KF68M
Memory capacity 8,192 bytes (user area)
Memory type FRAM
Data retention 10 years after writing (85°C or less)
Memory life One trillion writes for each block (85°C or less), Access frequency
2
The number of accesses is the total number of reads and writes.
: One trillion accesses
Ambient operating temperature −20 to 85°C (with no icing)
Ambient storage temperature −40 to 125°C (with no icing)
Ambient operating humidity 35% to 85%
Degree of protection IP68 (IEC 60529:2001), Oil resistance equivalent to IP67G (JIS C 0920:2003, Appendix 1)
2
Oil resistance has been tested using a specific oil as defined in the OMRON test method.
.
IPX9K (DIN 40 050)
Vibration resistance No abnormality after application of 10 to 2,000 Hz, 1.5-mm double amplitude, acceleration: 150 m/s², 10 sweeps each in X, Y, and Z directions for 15 minutes each No abnormality after application of 10 to 500 Hz, 1.5-mm double amplitude, acceleration: 100 m/s², 10 sweeps each in X, Y, and Z directions for 11 minutes each
Shock resistance No abnormality after application of 500 m/s², 3 times each in X, Y, and Z directions (Total: 18 times)
Dimensions (W×H×D) 40 × 40 × 5 mm 86 × 54 × 10 mm
Materials Exterior: PPS resin
Weight Approx. 11.5 g Approx. 12 g Approx. 44 g Approx. 46 g
Metal countermeasures None Provided None Provided
Note:

For details, refer to the User’s Manual (Cat. No. Z339).

V680-series

RF Tag (1-kbyte Memory)

Item V680-D1KP54T V680-D1KP66T V680-D1KP66MT V680-D1KP66T-SP
Memory capacity 1,000 bytes (user area)
Memory type EEPROM
Data retention time 10 years after writing (85°C or less), 0.5 year after writing (85 to 125°C)
Total data retention at high temperatures exceeding 125°C is 10 hours
2
After storing data at high temperatures, rewrite the data even if changes are not required. High temperatures are those exceeding 125°C up to 180°C.
10 years after writing (85°C or less)
Write endurance 100,000 writes for each block (25°C)
Ambient operating temperature
(during transmission)
−25 to 85°C (with no icing) During RF Tag communications:
−25 to 70°C (with no icing)Not during RF Tag communications:
−40 to 110°C (with no icing)
Ambient storage temperature
(during data backup)

−40 to 125°C (with no icing)

Heat resistance:
1,000 thermal cycles each of 30 minutes at −10°C/150°C,
High temperature storage: 1,000 hours at 150°C
2
150°C heat resistance: The heat resistance has been checked at 150°C for up to 1,000 hours, and thermal shock has been checked through testing 1,000 thermal cycles each of 30 minutes at –10/150°C. (Test samples: 22, defects: 0)

200 thermal cycles each of 30 minutes at −10°C/180°C,
High temperature storage: 200 hours at 180°C
2
180°C heat resistance: The heat resistance has been checked at 180°C for up to 200 hours, and thermal shock has been checked through testing 200 thermal cycles each of 30 minutes at –10°C/180°C. (Test samples: 22, defects: 0)
−40 to 110°C (with no icing)
Ambient operating humidity 35 to 95%
Degree of protection

IP67 (IEC 60529:2001)

Oil resistance equivalent to IP67G
(JIS C 0920:2003, Appendix 1)
2
Oil resistance has been tested using a specific oil as defined in the OMRON test method.

IP68 (IEC 60529:2001)

Oil resistance equivalent to IP67G
(JIS C 0920:2003, Appendix 1)
2
Oil resistance has been tested using a specific oil as defined in the OMRON test method.
IP67
Vibration resistance No abnormality after application of 10 to 2,000 Hz, 1.5-mm double amplitude,
acceleration: 150 m/s², 10 sweeps each in X, Y, and Z directions for 15 minutes each
Shock resistance No abnormality after application of 500 m/s², 3 times each in X, Y, and Z directions (Total: 18 times)
Appearance 20 dia. × 2.7 mm 34 × 34 × 3.5 mm 95×36.5×6.5 mm
(excluding protruding parts)
Materials PPS resin

Exterior: PFA fluororesin

RF Tag filling: PPS resin

Weight Approx. 2 g Approx. 6 g Approx. 7.5 g Approx. 20 g
Metal countermeasures None None Provided None
Note:

For details, refer to the User's Manual (Cat. No. Z339).

RF Tag (1-kbyte Memory with High-temperature Capability)

Item V680-D1KP58HTN
Memory capacity 1,000 bytes (user area)
Memory type EEPROM
Data retention

10 years after writing (85°C or less), 0.5 year after writing (85 to 125°C)

Total data retention at high temperatures exceeding 125°C is 10 hours

2
After storing data at high temperatures, rewrite the data even if changes are not required. High temperatures are those exceeding 125°C up to 180°C.

Write endurance 100,000 writes for each block (25°C)
Ambient operating temperature
(during transmission)
−25 to 85°C (with no icing)
Ambient storage temperature
(during data backup)
−40 to 250°C (with no icing) (Data retention: −40 to 125°C)
Ambient storage humidity No restrictions.
Degree of protection

IP67 (IEC 60529:2001)

Oil resistance equivalent to IP67G (JIS C 0920:2003, Appendix 1)

2
Oil resistance has been tested using a specific oil as defined in the OMRON test method.

Vibration resistance No abnormality after application of 10 to 2,000 Hz, 1.5-mm double amplitude, acceleration: 150 m/s²,
10 sweeps each in X, Y, and Z directions for 15 minutes each
Shock resistance No abnormality after application of 500 m/s², 3 times each in X, Y, and Z directions (Total: 18 times)
Materials Exterior: PPS resin
Weight Approx. 70 g
Note:

For details, refer to the User's Manual (Cat. No. Z339).

Reader/Writer

EtherNet/IP, PROFINET

Item

V680S-HMD63-EIP

V680S-HMD63-PNT

V680S-HMD64-EIP

V680S-HMD64-PNT

V680S-HMD66-EIP

V680S-HMD66-PNT

Dimensions (W×H×D) 50×50×30mm
(excluding protruding parts and cables)
75×75×40mm
(excluding protruding parts and cables)
120×120×40mm
(excluding protruding parts and cables)
Power supply voltage 24 VDC (−15% to 10%)
Consumption current 0.2 A max.
Ambient operating temperature −10 to +55°C (with no icing)
Ambient operating humidity 25% to 85% (with no condensation)
Ambient storage temperature −25 to 70°C (with no icing)
Ambient storage humidity 25% to 85% (with no condensation)
Insulation resistance 20 MΩ min. (at 500 VDC) between cable terminals and case
Dielectric strength 1,000 VAC, 50/60 Hz for 1 min between cable terminals and case
Vibration resistance No abnormality after application of 10 to 500 Hz, 1.5-mm double amplitude, acceleration: 100 m/s²,
10 sweeps in each of 3 axis directions (up/down, left/right, and forward/backward) for 11 minutes each
Shock resistance No abnormality after application of 500 m/s², 3 times each in 6 directions (Total: 18 times)
Degree of protection

IP67 (IEC 60529: 2001)

Oil resistance equivalent to IP67F (JIS C 0920: 2003, Appendix 1)

2
Oil resistance has been tested using a specific oil as defined in the OMRON test method.

Materials Case: PBT resin, Filled resin: Urethane resin
Mass Approx. 240 g Approx. 390 g Approx. 760 g
Installation method Reader/Writer: Two M4 screws
(Use a screw of 12 mm or more in length.)

Branch cable joint: One M4 screws

Four M4 screws
(Use a screw of 12 mm or more in length.)
Host device communications interface Ethernet 10BASE-T/100BASE-TX
Host device communications protocol EtherNet/IP, PROFINET
Accessories Instruction Sheet, Description of Regulations and Standard, IP address label
Note:

The 0.5 m cable with two M12 connectors is attached to the Reader/Writer. The cable cannot be removed.

Modbus TCP

Item V680S-HMD63-ETN V680S-HMD64-ETN V680S-HMD66-ETN
Dimensions 50×50× 30
(excluding protruding parts)
75× 75× 40
(excluding protruding parts)
120× 120× 40mm
(excluding protruding parts)
Power supply voltage 24 VDC (–15% to 10%)
Consumption current 0.2A max.
Ambient operating temperature –10 to 55°C (with no icing)
Ambient operating humidity 25% to 85% (with no condensation)
Ambient storage temperature −25 to 70°C (with no icing)
Ambient storage humidity 25% to 85% (with no condensation)
Insulation resistance 20 MΩ min. (at 500 VDC) between cable terminals and case
Dielectric strength 1,000 VAC, 50/60 Hz for 1 min between cable terminals and case
Vibration resistance No abnormality after application of 10 to 500 Hz, 1.5-mm double amplitude, acceleration: 100 m/s²,
10 sweeps in each of 3 axis directions (up/down, left/right, and forward/backward) for 11 minutes each
Shock resistance No abnormality after application of 500 m/s², 3 times each in 6 directions (Total: 18 times)
Degree of protection

IP67 (IEC 60529: 2001)

Oil resistance equivalent to IP67F (JIS C 0920: 2003, Appendix 1)

2
Oil resistance has been tested using a specific oil as defined in the OMRON test method.

Materials Case: PBT resin, Filled resin: Urethane resin
Mass Approx. 120 g Approx. 270 g Approx. 640 g
Installation method Two M4 screws
(Use a screw of 12 mm or more in length.)
Four M4 screws
(Use a screw of 12 mm or more in length.)
Host device communications
interface
Ethernet 10BASE-T/100BASE-TX
Host device communications
protocol
MODBUS TCP
Accessories Instruction sheet, Description of Regulations and Standard, IP address label, Ferrite core
2
Provided only with the V680S-HMD66-ETN.

System configuration

The below shows the configuration for 1 to 1 connection. Multiple Reader/Writers can be connected by using a switching hub.

EtherNet/IP, PROFINET

Modbus TCP

How can we help you?

If you have a question or would like to ask for a quote, please contact us or send a request.

+44 (0)870 752 0861
Contact us

Contact me V680/V680S

v680s group 2015 cropped sm rgb prod

Please, complete all the fields marked with *. Your personal details will be handled confidentially.

Text error notification

Text error notification

Text error notification

Text error notification

Text error notification

Country error notification

Details

Text area error notification

Checkbox error notification

Checkbox error notification

Thank you for submitting your request. We will come back to you as soon as possible.

We are experiencing technical difficulties. Your form submission has not been successful. Please accept our apologies and try again later. Details: [details]

Download
+44 (0)870 752 0861
+44 (0)870 752 0861
Request quotation
Request quotation

Quotation for V680/V680S

By completing this form you can request a quotation. Your personal details will be handled confidentially.

v680s group 2015 cropped sm rgb prod

Personal details

V680/V680S

Text error notification

Text error notification

Text error notification

Text error notification

Text error notification

Country error notification

Quote details

Select notification error

Select notification error

Text area error notification

Checkbox error notification

Checkbox error notification

Thank you for requesting a quotation. We will provide you with the required information as soon as possible.

We are experiencing technical difficulties. Your form submission has not been successful. Please accept our apologies and try again later. Details: [details]

Download
Request quotation
Request quotation

Downloads

download
CJ-series various models (Europe only) Discontinuation Notice
enPDF 535 KB
download
EAC Mark removal Discontinuation Notice
enPDF 221 KB
download
NX-V680C Users Manual
enPDF 12.3 MB
download
Omron V680S-HMD6X-PNT PROFINET GSDML file
enZIP 3.07 KB
download
RFID Technical Manual
enPDF 2.33 MB
download
NX-V680C Users Manual
enPDF 12.3 MB
download
RFID Technical Manual
enPDF 2.33 MB