Login

We are experiencing technical difficulties. Your form submission has not been successful. Please accept our apologies and try again later. Details: [details]

Download

Register

Text error notification

Text error notification

Checkbox error notification

Checkbox error notification

We are experiencing technical difficulties. Your form submission has not been successful. Please accept our apologies and try again later. Details: [details]

Download

Thank you for registering

An email to complete your account has been sent to

Return to the website

get direct access

Fill in your details below and get direct access to view content

Text error notification

Text error notification

Checkbox error notification

Checkbox error notification

We are experiencing technical difficulties. Your form submission has not been successful. Please accept our apologies and try again later. Details: [details]

Download

Thank you for your interest

You now have access to KM-N2

A confirmation email has been sent to

Continue to page

KM-N2

  • EPLAN parts data
  • KM-N2-FLK Datasheet
  • Thank you for downloading the KM-N2-FLK Datasheet

    Download again

    Did you know that 4 out of 5 distributors buy this product in a bundle?

    There are many variations of passages of Lorem Ipsum available, but the majority have suffered alteration in some form, by injected humour, or randomised words which don't look even slightly believable.

    Read more
Features

Global power monitor for mounting inside control panels

  • Solve design, installation, and operation topics.
  • You can measure up to four circuits with one power monitor.
  • Use general-purpose CTs and handle a variety of worksites.
  • Large, easy-to-read white LCD for improved visibility.
  • IEC Class 0.5S high-precision measurements (Power monitor only).
Specifications & ordering info

Ordering information

Applicable circuits and rated input voltage

Power supply voltage

Dimensions (W×H×D)

Communications

Order code

Single-phase, 2-wire:
100 to 277 VAC
Single-phase, 3-wire:
100 to 240 VAC (L-N) or 200 to 480 VAC (L-L)
Three-phase, 3-wire:
100 to 277 VAC (L-N) or 173 to 480 VAC (L-L)
Three-phase, 4-wire:
100 to 277 VAC (L-N) or 173 to 480 VAC (L-L)

Rated input voltage 85 to 115%

90 × 65 × 90 mm

RS-485, Modbus (RTU) or
CompoWay/F

KM-N2-FLK

Specifications

Ratings

Applicable circuits

Single-phase two-wire, single-phase three-wire, three-phase three-wire, and three-phase four-wire

Maximum number of measured circuits1

Single-phase two-wire: 4 circuits, single-phase three-wire or three-phase three-wire: 2 circuits, three-phase four-wire: 1 circuit

Rated input voltages (power supply voltages)

Single-phase, 2-wire: 100 to 277 VAC
Single-phase, 3-wire: 100 to 240 VAC (L-N) or 200 to 480 VAC (L-L)
Three-phase, 3-wire: 100 to 277 VAC (L-N) or 173 to 480 VAC (L-L)
Three-phase, 4-wire: 100 to 277 VAC (L-N) or 173 to 480 VAC (L-L)

Allowable supply and input voltage range

85% to 115% of rated power supply voltage

Power consumption

7 VA max.

Input current (CT2 primary-side current)2

General-purpose CT: 1 A or 5 A

Rated load: 0.5 VA min.

Rated input frequency

50/60 Hz

Allowable input current

6 A max.

Ambient operating temperature

−25 to 55°C (with no condensation or icing)

Storage temperature

−25 to 85°C (with no condensation or icing)

Ambient and storage humidity

25% to 85%

Operating altitude

2,000 m max.

Installation environment

Overvoltage category II, pollution degree 2, measurement category II

Electromagnetic environment

Industrial electromagnetic environment (EN/IEC 61326-1 Table 2)

Compliant standards

EN 61010-2-030, EN 61326-1, and UL 61010-1

Performance

Measurement specifications

Active power

IEC 62053-22 class 0.5S (Accuracy ±0.5% F.S. ±1 digit)3

Reactive power

IEC 62053-23 class 2 (Accuracy ±2% F.S. ±1 digit)1

Sampling cycle

80 ms for 50 Hz and 66.7 ms for 60 Hz

Measured items

Energy consumption (active, regenerative, and reactive), power (active and reactive), current, voltage, power factor, and frequency

Insulation resistance

  • Between all electrical circuits and the case: 20 MΩ min. (at 500 VDC)
  • Between all power supply and voltage inputs and all communications and pulse output terminals:: 20 MΩ max. (at 500 VDC)

Dielectric strength

  • Between all electrical circuits and the case: 2,200 VAC for 1 min
  • Between all voltage and current inputs and all communications and pulse output terminals: 2,200 VAC for 1 min

Vibration resistance

Single amplitude: 0.1 mm, Acceleration: 15 m/s 2 , Frequency: 10 to 150 Hz, 10 sweeps for 8 min each along three axes

Shock resistance

150 m/s 2 , 3 times each in 6 directions (up/down, left/right, forward/backward)

Weight

Approx. 350 g (Power Monitor only)

Degree of protection

IP20

Installation method

DIN Rail mounting

Pulse output

Number of outputs

Number of outputs: 4 (photoMOS relay outputs)
Used for the total power consumption pulse output.

Output capacity

50 mA at 40 VDC
ON residual voltage: 1.5 V max. (for output current of 50 mA)
OFF leakage current: 0.1 mA max.

Output unit

1, 10, 100, 1k, 5k, 10k, 50k, or 100k (wh)
Pulse ON time: 500 ms (Cannot be changed.)

Communications interface

Communications method

RS-485 (2-wire half-duplex with start-stop synchronization)

Communications protocol

Modbus (RTU): Binary. CompoWay/F: ASCII

Baud rate

1.2, 2.4, 4.8, 9.6, 19.2, or 38.4 kbps

Data length

Data length: 7 or 8 bits
Stop bits: 1 or 2 bits
Vertical parity: Even, odd, or none

Maximum transmission distance

1,200 m1

Maximum number of connected Power Monitors

Modbus: 99, CompoWay/F: 31


1. A CT with a different capacity can be specified for each circuit.

2. The KM-series CTs (the KM20-CTF or KM-NCT series) cannot be used. Use general-purpose CTs with a secondary-side output of 1 A or 5 A.

3. The error of the CT or VT is not included.

1. A CT with a different capacity can be specified for each circuit.

2. The KM-series CTs (the KM20-CTF or KM-NCT series) cannot be used. Use general-purpose CTs with a secondary-side output of 1 A or 5 A.

3. The error of the CT or VT is not included.

Have a question?

We are ready to help.

Contact us

Subscribe to product updates

Newsletters about product innovations, solutions and services, directly in your inbox.

Thank you for subscribing to Omron's eNews. You will shortly receive an e-mail from us. This e-mail contains a link which activates your email newsletter subscription. This method is used due to legal issues and to make certain that no-one can abuse your e-mail address.

We are experiencing technical difficulties. Your form submission has not been successful. Please accept our apologies and try again later. Details: [details]

Download

Product documentation

Download datasheets, manuals and brochures.

Browse download center

Training courses

Get the training from our best engineers. Beginner to advanced level.

View training courses