K8AK-AS

Features

Single-phase current relay

These single-phase current relays monitor over- and undercurrents. Manual resetting and automatic resetting are supported by one relay. The start-up lock and operating time can be set separately. The relay warning status is easily monitored with the LED indicator.
  • Single-phase current relay
  • In 22.5 mm wide industrial housing
  • Under or over control
  • Supply voltages: 24 VAC/DC, 100 to 240 VAC
  • Easy wiring with ferrules
Specifications & ordering info

Ordering information

Measuring current

Supply voltage

Order code

2 to 20 mA AC/DC,
10 to 100 mA AC/DC,
50 to 500 mA AC/DC

24 VAC/DC

K8AK-AS1 24 VAC/DC

100 to 240 VAC

K8AK-AS1 100-240 VAC

0.1 to 1 A AC/DC,
0.5 to 5 A AC/DC,
0.8 to 8 A AC/DC

24 VAC/DC

K8AK-AS2 24 VAC/DC

100 to 240 VAC

K8AK-AS2 100-240 VAC

10 to 100 A AC,
20 to 200 A AC

24 VAC/DC

K8AK-AS3 24 VAC/DC

100 to 240 VAC

K8AK-AS3 100-240 VAC

Accessories

Current transformer

Input range

Applicable relay

Order code

 

10 to 100 A AC, 20 to 200 A AC

K8AK-AS3

K8AC-CT200L

Note: The K8AK-AS3 is designed to be used in combination with the K8AC-CT200L (direct input not possible)

Specifications

Ambient operating temperature

-20 to 60°C (with no condensation or icing)

Storage temperature

-25 to 65°C (with no condensation or icing)

Operating voltage range

85% to 110% of rated operating voltage

Rated power supply frequency

50/60 Hz±5 Hz (AC power supply)

Output relays
(1 × SPDT, normally closed operation)

Resistive load

5 A at 250 VAC or at 30 VDC

Maximum contact voltage

250 VAC or 30 VDC

Maximum contact current

5 A

Maximum switching capacity

1,250 VA, 150 W

Mechanical life

10,000,000 operations

Electrical life

50,000 operations at 5 A, 250 VAC or 30 VDC

Degree of protection

Terminal section: IP20

Case material

PC and ABS

Weight

Approx. 150 g

Operating power

Isolated power supply

2.0 VA/1.1 W max. at 24 VAC/DC, 4.6 VA max. at 100 to 240 VAC

Operate (SV)

Operating value setting range

10% to 100% of maximum measuring current

Operating value

100% operation at set value

Reset (HYS.)

Hysteresis

5% to 50% of operating value

Resetting method

Manual reset/automatic reset (switchable)
Manual reset: Turn OFF operating power for 1 s or longer

Operating time (T)

0.1 to 30 s

Operating power ON lock (LOCK)

0 to 30 s (The startup lock timer starts when the input has reached approximately 30% or more of the set value.)

Note: Enabled only for overcurrent operation

Repeat error

Operating value

±0.5% full scale (at 25°C and 65% humidity, rated power supply voltage, DC or 50/60 Hz sine wave input)

Operating time

±50 ms (at 25°C and 65% humidity, rated power supply voltage)

Input frequency range

K8AK-AS1/-AS2

DC input or AC input (45 to 65 Hz)

K8AK-AS3

AC input (45 to 65 Hz)

Overload capacity

K8AK-AS1/-AS2

Continuous input at 120% of maximum input, 1 s at 150%

K8AK-AS3

Continuous input at 120%, 30 s at 200%, and 1 s at 600% with an OMRON CT (K8AC-CT200L)

Indicators

Power (PWR): Green LED, relay output (RY): Yellow LED, alarm outputs (ALM): Red LED

Applicable standards

Conforming standards

EN 60947-5-1
Installation environment (pollution level 2, installation category III)

EMC

EN 60947-5-1

Safety standards

UL 508 (Recognition), Korean Radio Waves Act (Act 10564), CSA and CCC

Size in mm (H × W × D)

90 × 22.5 × 100

Have a question?

We are ready to help.

Contact us

Subscribe to product updates

Newsletters about product innovations, solutions and services, directly in your inbox.

Thank you for subscribing to Omron's eNews. You will shortly receive an e-mail from us. This e-mail contains a link which activates your email newsletter subscription. This method is used due to legal issues and to make certain that no-one can abuse your e-mail address.

We are experiencing technical difficulties. Your form submission has not been successful. Please accept our apologies and try again later. Details: [details]

Download

Product documentation

Download datasheets, manuals and brochures.

Browse download center

Training courses

Get the training from our best engineers. Beginner to advanced level.