H3YN-B

Features

Compact, Multi-function Timers with Plug-in socket

  • The Plug-in socket with Push-in plus technology, PYF-__-PU is available for easy wiring.
  • Easy replacement and reduces your maintenance time.
  • Space saving by Slim design 21.5 mm width.
  • Large transparent time setting knob facilitates time setting.
Specifications & ordering info

Ordering information

Operating modes

Control output

Supply voltage

Order code

Short-time range (0.1 s to 10 min)

Long-time range (0.1 m to 10 h)

On-delay, Interval,
Flicker OFF-start, Flicker ON Start

DPDT

24 VAC

H3YN-2-B AC24

H3YN-21-B AC24

24 VDC

H3YN-2-B DC24

H3YN-21-B DC24

12 VDC

H3YN-2-B DC12

H3YN-21-B DC12

100 to 120 VAC

H3YN-2-B AC100-120

H3YN-21-B AC100-120

200 to 230 VAC

H3YN-2-B AC200-230

H3YN-21-B AC200-230

4PDT

24 VAC

H3YN-4-B AC24

H3YN-41-B AC24

24 VDC

H3YN-4-B DC24

H3YN-41-B DC24

12 VDC

H3YN-4-B DC12

H3YN-41-B DC12

100 to 120 VAC

H3YN-4-B AC100-120

H3YN-41-B AC100-120

200 to 230 VAC

H3YN-4-B AC200-230

H3YN-41-B AC200-230

4PDT, Twin Contact

24 VDC

H3YN-4-Z-B DC24

H3YN-41-Z-B DC24

Accessories

Plug-in Socket

Type

Timer

Order code

Screwless socket with Push-in plus technology

H3YN-2-B/H3YN-21-B

PYF-08-PU-L

H3YN-4-B/H3YN-41-B/
H3YN-41-Z-B

PYF-14-PU-L

Hold-down clip

Type

Order code

PYF-08-PU-L/PYF-14-PU-L

Y92H-3 (2 pcs in a pack)

Specifications

Item

H3YN-2-B/H3YN-21-B

H3YN-4-B/H3YN-41-B/H3YN-41-Z-B

Time ranges

0.1 s to 10 min (1 s, 10 s, 1 min, or 10 min max. selectable)

0.1 min to 10 h (1 min, 10 min, 1 h, or 10 h max. selectable)

Rated supply voltage1

24, 100 to 120, 200 to 230 VAC (50/60 Hz), 12, 24 VDC

Pin type

Plug-in

Operating mode

ON-delay, interval, flicker OFF-start, or flicker-ON start selectable by DIP switch

Operating voltage range

85% to 110% of rated supply voltage (12 VDC: 90% to 110% of rated supply voltage)2

Reset voltage

10% max. of rated supply voltage

Control outputs

DPDT:
5 A at 250 VAC, resistive load (cos φ = 1)
The minimum applicable load is 1 mA at 5 VDC (P reference value).
Contact materials: Ag

4PDT:
3 A at 250 VAC, resistive load (cos φ = 1)
H3YN-4-B/-41-B series: The minimum applicable load is 1 mA at 1 VDC (P reference value)
H3YN-4-Z/-41-Z-B series: The minimum applicable load is 1 mA at 1 VDC (P reference value)
Contact materials: Au-clad + Ag-alloy

Accuracy of operating time

±1% FS max. (1 s range: ±1%±10 ms max.)

Setting error

±10% ±50 ms FS max.

Reset time

Min. power-opening time: 0.1 s max. (including halfway reset)

Influence of voltage

±2% FS max.

Influence of temperature

±2% FS max.

Ambient temperature

Operating: −10°C to 55°C (with no icing)
Storage: −25°C to 65°C (with no icing)

Degree of protection

IP40 (Terminal screw sections are excluded.)

Size in mm (H × W × D)

28 × 21.5 × 52.6


1. Refer to Safety Precautions for All Times when combining the timer with an AC 2-wire proximity sensor.
2. When using the H3RN in any place where the ambient temperature is more than 50°C, supply 90% to 110% of the rated voltages (12 VDC: 95% to 110% of the rated voltage).
1. Refer to Safety Precautions for All Times when combining the timer with an AC 2-wire proximity sensor.
2. When using the H3RN in any place where the ambient temperature is more than 50°C, supply 90% to 110% of the rated voltages (12 VDC: 95% to 110% of the rated voltage).

Have a question?

We are ready to help.

Contact us

Subscribe to product updates

Newsletters about product innovations, solutions and services, directly in your inbox.

Thank you for subscribing to Omron's eNews. You will shortly receive an e-mail from us. This e-mail contains a link which activates your email newsletter subscription. This method is used due to legal issues and to make certain that no-one can abuse your e-mail address.