G3PA

Features

Solid State Relays with exchangeable power cartridge

Optimum design of the heat sink has contributed to the downsizing of this product. The power element cartridges of G3PA are easily replaceable for easy maintenance. G3PA can be mounted on a DIN-rail or using screws.

  • 10-60A output current
  • 24-480VAC output voltages
  • Applicable with 3-phase loads
  • Replaceable power element cartridges
  • All features can be delivered with or without heat sink
Specifications & ordering info

Ordering information

Rated output load

Zero cross function

Rated input voltage

Operating voltage range

Input
current impedance

Voltage level

Size in mm
(H×W×D)

Order code

Must operate voltage

Must release voltage

24 to 240 VAC

10 A

Yes

5 to 24 VDC

4 to 30 VDC

7 mA max.

4 VDC max.

1 VDC min.

100×27×100

G3PA-210B-VD DC5-24

20 A

100×37×100

G3PA-220B-VD DC5-24

40 A

100×47×100

G3PA-240B-VD DC5-24

60 A

100×110×100

G3PA-260B-VD DC5-24

10 A

24 VAC

19.2 to 26.4 VAC

1.4 kΩ ±20%

19.2 VAC max.

4.8 VAC min.

100×27×100

G3PA-210B-VD AC24

20 A

100×37×100

G3PA-220B-VD AC24

40 A

100×47×100

G3PA-240B-VD AC24

60 A

100×110×100

G3PA-260B-VD AC24

180 to 400 VAC

20 A

12 to 24 VDC

9.6 to 30 VDC

7 mA max.

9.2 VDC max.

1 VDC min.

100×37×100

G3PA-420B-VD DC12-24

30 A

100×47×100

G3PA-430B-VD DC12-24

200 to 480 VAC

20 A

100×37×100

G3PA-420B-VD-2 DC12-24

30 A

100×47×100

G3PA-430B-VD-2 DC12-24

50 A

100×110×100

G3PA-450B-VD-2 DC12-24

Accessories

 

Replacement parts: Power device cartridges

Load voltage range

Carry current

Applicable SSR

Order code

19 to 264 VAC

10 A

G3PA-210B-VD DC5-24

G32A-A10-VD DC5-24

G3PA-210B-VD AC24

G32A-A10-VD AC24

20 A

G3PA-220B-VD DC5-24

G32A-A20-VD DC5-24

G3PA-220B-VD AC24

G32A-A20-VD AC24

40 A

G3PA-240B-VD DC5-24

G32A-A40-VD DC5-24

G3PA-240B-VD AC24

G32A-A40-VD AC24

60 A

G3PA-260B-VD DC5-24

G32A-A60-VD DC5-24

G3PA-260B-VD AC24

G32A-A60-VD AC24

150 to 440 VAC

20 A

G3PA-420B-VD DC12-24

G32A-A420-VD DC12-24

30 A

G3PA-430B-VD DC12-24

G32A-A430-VD DC12-24

180 to 528 VAC

20 A

G3PA-420B-VD-2 DC12-24

G32A-A420-VD-2 DC12-24

30 A

G3PA-430B-VD-2 DC12-24

G32A-A430-VD-2 DC12-24

50 A

G3PA-450B-VD-2 DC12-24

G32A-A450-VD-2 DC12-24

 

G32A-D__ enables 2 line switching of 3 phase configurations

Current flow

Applicable SSR

Order code

10 A

G3PA-210B-VD, G3PA-210BL-VD,
G3PA-220B-VD, G3PA-220BL-VD,
G3PA-420B-VD, G3PA-420B-VD-2

G32A-D20

20 A

30 A

G3PA-430B-VD, G3PA-430B-VD-2,
G3PA-240B-VD, G3PA-240BL-VD

G32A-D40

40 A

Specifications

Isolation

Phototriac coupler

Indicator

Yes

Ambient temperature

Operating: -30 to 80°C

Load voltage range

200 to 480 VAC: 180 to 528 VAC

24 to 240 VAC: 19 to 264 VAC

180 to 400 VAC: 150 to 440 VAC

Output ON drop

1.6 V (RMS) max.

Operate time

0.5 of load power source cycle + 1 ms max. (DC input, -B models)

1.5 of load power source cycle + 1 ms max. (AC input)
1 ms max. (-BL models)

Release time

0.5 of load power source cycle + 1 ms max. (DC input)

1.5 of load power source cycle + 1 ms max. (AC input)

Have a question?

We are ready to help.

Contact us

Subscribe to product updates

Newsletters about product innovations, solutions and services, directly in your inbox.

Thank you for subscribing to Omron's eNews. You will shortly receive an e-mail from us. This e-mail contains a link which activates your email newsletter subscription. This method is used due to legal issues and to make certain that no-one can abuse your e-mail address.

We are experiencing technical difficulties. Your form submission has not been successful. Please accept our apologies and try again later. Details: [details]

Download

Product documentation

Download datasheets, manuals and brochures.

Browse download center

Training courses

Get the training from our best engineers. Beginner to advanced level.

View training courses