Hockey puck style SSR with 5-90A output currents

All models feature the same compact dimensions to provide a uniform mounting pitch. A built-in varistor effectively absorbs external surges. The operation indicator enables monitoring operation.

  • 5-90A output current
  • 24-480VAC/5-200VDC output voltages
  • Built-in varistor
  • Operation indicator (red LED)
  • Protective cover for greater safety
Specifications & ordering info

Ordering information

Applicable output load

Zero cross function

Isolation

Rated input voltage

Must operate voltage

Must release voltage

Load current with/without heatsink at 40 °C

Size in mm (H×W×D)

Order code

24 to 240 VAC

5 A

Yes

Phototriac

5 to 24 VDC

4 VDC max.

1 VDC min.

0.1 to 5 A/0.1 to 3 A

58×43×27

G3NA-205B-UTU DC5-24

Photocoupler

100 to 120 VAC

75 VAC max.

20 VAC min.

G3NA-205B-UTU AC100-120

200 to 240 VAC

150 VAC max.

40 VAC min.

G3NA-205B-UTU AC200-240

10 A

Phototriac

5 to 24 VDC

4 VDC max.

1 VDC min.

0.1 to 10 A/0.1 to 4 A

58×43×27

G3NA-210B-UTU DC5-24

Photocoupler

100 to 120 VAC

75 VAC max.

20 VAC min.

G3NA-210B-UTU AC100-120

200 to 240 VAC

150 VAC max.

40 VAC min.

G3NA-210B-UTU AC200-240

20 A

Phototriac

5 to 24 VDC

4 VDC max.

1 VDC min.

0.1 to 20 A/0.1 to 4 A

58×43×27

G3NA-220B-UTU DC5-24

Photocoupler

100 to 120 VAC

75 VAC max.

20 VAC min.

G3NA-220B-UTU AC100-120

200 to 240 VAC

150 VAC max.

40 VAC min.

G3NA-220B-UTU AC200-240

40 A

Phototriac

5 to 24 VDC

4 VDC max.

1 VDC min.

0.1 to 40 A/0.1 to 6 A

58×43×27

G3NA-240B-UTU DC5-24

Photocoupler

100 to 120 VAC

75 VAC max.

20 VAC min.

G3NA-240B-UTU AC100-120

200 to 240 VAC

150 VAC max.

40 VAC min.

G3NA-240B-UTU AC200-240

50 A

Phototriac

5 to 24 VDC

4 VDC max.

1 VDC min.

0.1 to 50 A/0.1 to 6 A

58×43×27

G3NA-250B-UTU DC5-24

Photocoupler

100 to 120 VAC

75 VAC max.

20 VAC min.

G3NA-250B-UTU AC100-120

200 to 240 VAC

150 VAC max.

40 VAC min.

G3NA-250B-UTU AC200-240

75 A

Phototriac

5 to 24 VDC

4 VDC max.

1 VDC min.

1 to 75 A/1 to 7 A

58×43×30

G3NA-275B-UTU-2 DC5-24

Photocoupler

100 to 240 VAC

75 VAC max.

20 VAC min.

G3NA-275B-UTU-2 AC100-240

90 A

Phototriac

5 to 24 VDC

4 VDC max.

1 VDC min.

1 to 90 A/1 to 7 A

58×43×30

G3NA-290B-UTU-2 DC5-24

Photocoupler

100 to 240 VAC

75 VAC max.

20 VAC min.

G3NA-290B-UTU-2 AC100-240

5 to 200 VDC

10 A

No

Photocoupler

5 to 24 VDC

4 VDC max.

1 VDC min.

0.1 to 10 A/0.1 to 4 A

58×43×27

G3NA-D210B-UTU DC5-24

100 to 240 VAC

75 VAC max.

20 VAC min.

G3NA-D210B-UTU AC100-240

200 to 480 VAC

10 A

Yes

5 to 24 VDC

4 VDC max.

1 VDC min.

0.2 to 10 A/0.2 to 4 A

58×43×27

G3NA-410B-UTU DC5-24

100 to 240 VAC

75 VAC max.

20 VAC min.

G3NA-410B-UTU AC100-240

25 A

5 to 24 VDC

4 VDC max.

1 VDC min.

0.2 to 20 A/0.2 to 4 A

58×43×27

G3NA-425B-UTU-2 DC5-24

100 to 240 VAC

75 VAC max.

20 VAC min.

G3NA-425B-UTU-2 AC100-240

50 A

5 to 24 VDC

4 VDC max.

1 VDC min.

0.2 to 40 A/0.2 to 6 A

58×43×30

G3NA-450B-UTU-2 DC5-24

100 to 240 VAC

75 VAC max.

20 VAC min.

G3NA-450B-UTU-2 AC100-240

75 A

5 to 24 VDC

4 VDC max.

1 VDC min.

1 to 75 A/1 to 7 A

58×43×30

G3NA-475B-UTU-2 DC5-24

100 to 240 VAC

75 VAC max.

20 VAC min.

G3NA-475B-UTU-2 AC100-240

90 A

5 to 24 VDC

4 VDC max.

1 VDC min.

1 to 90 A/1 to 7 A

58×43×30

G3NA-490B-UTU-2 DC5-24

100 to 240 VAC

75 VAC max.

20 VAC min.

G3NA-490B-UTU-2 AC100-240

Accessories

Name

Applicable SSRs

Size in mm (H×W×D)1

Order code

One-touch mounting plates

-

NA

R99-12 FOR G3NA

Mounting bracket

G3NA-240B-UTU

NA

R99-11 FOR G3NA

Slim heat sink enabling DIN-rail mounting

G3NA-205B-UTU, G3NA-210B-UTU,
G3NA-D210B-UTU, G3NA-410B-UTU

100×47×51

Y92B-N50

G3NA-220B-UTU, G3NA-425B-UTU(-2)

100×75×100

Y92B-N100

G3NA-240B-UTU, G3NA-250B-UTU

100×104×100

Y92B-N150

G3NA-450B-UTU(-2)

190.5×130.5×100

Y92B-P250

G3NA-275B-UTU(-2), G3NA-290B-UTU(-2),
G3NA-475B-UTU(-2), G3NA-490B-UTU(-2)

172×110×150

Y92B-P250NF

Low-cost heat sink

G3NA-205B-UTU, G3NA-210B-UTU,
G3NA-D210B-UTU, G3NA-220B-UTU,
G3NA-410B-UTU, G3NA-425B-UTU(-2)

100×102×60

Y92B-A100

G3NA-240-B-UTU

150×102×60

Y92B-A150N

Specifications

Operating voltage range

5 to 24 VDC: 4 to 32 VDC

100 to 120 VAC: 75 to 132 VAC

200 to 240 VAC: 150 to 264 VAC

Output ON voltage drop

G3NA-2: 1.6 V (RMS) max.

G3NA-4: 1.8 V (RMS) max.

G3NA-D2: 1.5 V max.

Leakage current

5 mA (100 V)/10 mA (200 V)

G3NA-D2: 5 mA max. (200 VDC)

Load voltage range

200 to 480 VAC: 180 to 528 VAC

24 to 240 VAC: 19 to 264 VAC

5 to 200 VDC: 4 to 220 VDC

Ambient temperature

Operating: -30 to 80°C

Operate & release time

1/2 of load power source cycle + 1 ms max. (DC input)

1/2 of load power source cycle + 1 ms max. (DC input)

G3NA-D2

1 ms max. (DC input; release 5 ms),
30 ms max. (AC input)


1. Size includes heat sink + G3NA SSR

1. Size includes heat sink + G3NA SSR

Have a question?

We are ready to help.

Contact us

Subscribe to product updates

Newsletters about product innovations, solutions and services, directly in your inbox.

Thank you for subscribing to Omron's eNews. You will shortly receive an e-mail from us. This e-mail contains a link which activates your email newsletter subscription. This method is used due to legal issues and to make certain that no-one can abuse your e-mail address.

We are experiencing technical difficulties. Your form submission has not been successful. Please accept our apologies and try again later. Details: [details]

Download

Product documentation

Download datasheets, manuals and brochures.

Browse download center

Training courses

Get the training from our best engineers. Beginner to advanced level.

View training courses