E5_C

Features

High performance & simplicity

The next generation E5_C temperature controller is setting a new global standard in terms of precision and user-friendly design. Best control performance, easy set-up and outstanding visibility of the white IP66 LCD display have been integrated into a spacesaving housing only 60 mm deep.

  • Fast and precise regulation: 50 ms sampling loop period time
  • Easy to set up, and operate intuitively via CX-Thermo without power supply
  • Best contrast display using white LCD technology which is visible from a far distance and from any angle
  • Useful alarm and diagnosis functions for secure operation
  • Practical timer and logic operation functions eliminating the need of a PLC
  • Additional models with different features are available. Please check related product catalogue.

LCD display

High-contrast LCD display.jpg

High-contrast LCD display for best visibility

The large high-contrast white LED display featured by the new controllers provides exceptional clarity and can be read from a distance and from almost any angle, irrespective of the ambient lighting conditions. This not only maximises convenience for users, but also virtually eliminates the risk of reading errors.

Easy Set-up

Easy set-up quick and intuitive operation.jpg

Easy set-up, quick and intuitive operation

Setting up the controllers is made easy by the incorporation of auto-tuning algorithms, and by Omron’s new intuitive CX-Thermo support software. This enables faster parameter setting and straightforward device adjustment as well as greatly simplifying maintenance. A timesaving shift key is also provided on the controller front panel to allow rapid adjustment of set values, alternatively functions like Auto- Tuning or RUN/STOP could be associated

Precise control

Excellent control component.jpg

Excellent control performance

Accurate and responsive control is assured by the fast 50 ms sampling time of the new controllers and by the use of Omron’s 2-PID control algorithm. This powerful and patented algorithm provides enhanced control stability, which guarantees consistent product quality. For less demanding applications, the E5CC/E5EC controllers also support simple on/off control.

Useful functions

E5_C Ceramic Industry.jpg

Useful added functions and features

To maximise their versatility, the controllers incorporate a range of new features. These include a timer function, a heat and cool PID function, a set-point ramp function, enhanced alarm mode and enhanced manual output. These features are complemented by a remote set-point input, a transfer output, an event input and an auxiliary output.
Valve controlled furnaces with potentiometer feedback in ceramic industry
Applications

Bag sealing

In sealing applications speed of recovery is very important. Each time the sealing jaws close heat is drawn away into the product. The ability of the E5_C to read and react to any drop in temperature means that the quality of the seal is maintained while operating at high or low speeds. In case of alarm or malfunction the bright blinking display is warning the operator instantly so he can carry out counter measures

Harsh environment

Control products can be subjected to harsh environments where they can be splashed during the process or covered in dust or get warm through their location. The E5CC, E5CSV, H7CX, H5CX and K3HB all feature a NEMA4X (IP66 equivalent) front panels so are suitable for the use in these applications, also the low profile fascia means that they are less prominent in the front of the panel and so less likely to become dirty.

Oven control

External influences can cause the temperature to deviate from the required set value. With the E5CC it is possible to program the level at which the display starts blinking. Alarm options include deviation from set point, where if the set point is changing the alarm moves with it. Absolute alarms where they are referenced to 0, standby so the alarms will not be active during the set point has been reached. Latching which means that once triggered they can only be deactivated by removing power. This is ideal for remote or unmanned processes, as the alarm will remain until the machinery is next visited.

Baking oven

In many applications it is important to control the speed of approach to set point as well as maintain it at a preset time once reached. This rate of rise control helps to prevent over cooking of the outside of the product. However multistage control is not normally required. The E5CC contains a simple two stage function, controlling the rise to set point and also the sinking of temperature versus time can be programmed.
Expertise

Applications

Faster input sampling and control period

This gives faster, more precise heater control in rapidly changing, disturbance-sensitive applications. With a sampling period time of only 50ms any quick changing processes can be reliably regulated.

Process Value blinking display

This provides crystal-clear process status, even from a distance and without the need for interpreting the values. When one of the heaters is not at set-point the Process Value can start blinking to alert any member of staff (detecting a bad sealing at an early stage, for example).

Loop break alarm and sensor break alarm (with forced MV option)

In plastics production the tool used to make the product is changed quite often. Frequent reconnecting of the sensor or heater can result in a wire break (a broken thermocouple, for example). These alarms quickly detect such problems in the process.

Basic (2-step) programmer

In many thermal processes (food, brick, pottery etc.) a small element of timing is required. This feature enables you to ramp up to a set-point and set the dwell time period. At the end of this time, the process stops or continues with an indication alarm to alert the operator. With this feature, a fixed minimum or maximum curing/baking time is assured in a smooth, controlled way.   Alternatively you can set different steepness for the ramp-down period, e.g. allowing a soft decrease of temperature to avoid structural cracks of the heat treated object.

Easy to connect, set-up and operate

The E5_C series can be easily connected, set-up and operated in only a few steps using the instrument’s 5 front keys. Our CX-Thermo software and useful navigation assistant for intuitive settings is allowing a very quick parameter setting, easier device adjustment and simpler maintenance.
Specifications & ordering info

Ordering information

E5CC (48 × 48 mm) Screw terminals

Control Output

Option no

Option description

Alarm outputs

Order code

100 to 240 VAC

24 VAC/DC

Out1: Relay

Out2: non

000

No option

3

E5CC-RX3A5M-000

E5CC-RX3D5M-000

001

HB/HS alarm for 1-phase heaters, 2 EV inputs

3

E5CC-RX3A5M-001

E5CC-RX3D5M-001

003

HB/HS alarm for 3-phase heaters, RS485

3

E5CC-RX3A5M-003

E5CC-RX3D5M-003

006

2 EV inputs, transfer output

3

E5CC-RX3A5M-006

E5CC-RX3D5M-006

007

2 EV inputs, remote SP

3

E5CC-RX3A5M-007

E5CC-RX3D5M-007

Out1: Voltage (pulse)

Out2: non

000

No option

3

E5CC-QX3A5M-000

E5CC-QX3D5M-000

001

HB/HS alarm for 1-phase heaters, 2 EV inputs

3

E5CC-QX3A5M-001

E5CC-QX3D5M-001

003

HB/HS alarm for 3-phase heaters, RS485

3

E5CC-QX3A5M-003

E5CC-QX3D5M-003

006

2 EV inputs, transfer output

3

E5CC-QX3A5M-006

E5CC-QX3D5M-006

007

2 EV inputs, remote SP

3

E5CC-QX3A5M-007

E5CC-QX3D5M-007

Out1: Linear current

Out2: non

000

No option

3

E5CC-CX3A5M-000

E5CC-CX3D5M-000

004

RS485, 2 EV inputs

3

E5CC-CX3A5M-004

E5CC-CX3D5M-004

006

2 EV inputs, transfer output

3

E5CC-CX3A5M-006

E5CC-CX3D5M-006

007

2 EV inputs, remote SP

3

E5CC-CX3A5M-007

E5CC-CX3D5M-007

Note: Other models with 2 control outputs, 4 EV inputs or with different kind of option combination are available on request. Please contact the local sales office for special request.

E5CC (48 × 48 mm) Push-in plus terminals

Control Output

Option no

Option description

Alarm outputs

Order code

100 to 240 VAC

24 VAC/DC

Out1: Relay Out2: non

0

No option

2

E5CC-RX2ABM-000

E5CC-RX2DBM-000

1

HB/HS alarm for 1-phase heaters, 2 EV inputs

2

E5CC-RX2ABM-001

E5CC-RX2DBM-001

2

HB/HS alarm for 1-phase heaters, RS485

2

E5CC-RX2ABM-002

E5CC-RX2DBM-002

4

RS485, 2 EV inputs

2

E5CC-RX2ABM-004

E5CC-RX2DBM-004

6

2 EV inputs, Tranfer output

2

E5CC-RX2ABM-006

E5CC-RX2DBM-006

Out1: Voltage (pulse) Out2: non

0

No option

2

E5CC-QX2ABM-000

E5CC-QX2DBM-000

1

HB/HS alarm for 1-phase heaters, 2 EV inputs

2

E5CC-QX2ABM-001

E5CC-QX2DBM-001

2

HB/HS alarm for 1-phase heaters, RS485

2

E5CC-QX2ABM-002

E5CC-QX2DBM-002

4

RS485, 2 EV inputs

2

E5CC-QX2ABM-004

E5CC-QX2DBM-004

6

2 EV inputs, Tranfer output

2

E5CC-QX2ABM-006

E5CC-QX2DBM-006

E5EC (48 × 96 mm)/E5AC (96 × 96 mm) Screw terminals

Control Output

Option no

Option description

Alarm outputs

Order code

100 to 240 VAC

24 VAC/DC

Out1: Relay

Out2: non

000

No option

4

E5_C-RX4A5M-000

E5_C-RX4D5M-000

009

HB/HS alarm for 3-phase heaters, RS485, 2 EV inputs

4

E5_C-RX4A5M-009

E5_C-RX4D5M-009

010

HB/HS alarm for 1-phase heaters, 4 EV inputs

4

E5_C-RX4A5M-010

E5_C-RX4D5M-010

011

HB/HS alarm for 1-phase heaters, 6 EV inputs, remote SP, transfer output

4

E5_C-RX4A5M-011

E5_C-RX4D5M-011

Out1: Voltage (pulse)

Out2: non

000

No option

4

E5_C-QX4A5M-000

E5_C-QX4D5M-000

009

HB/HS alarm for 3-phase heaters, RS485, 2 EV inputs

4

E5_C-QX4A5M-009

E5_C-QX4D5M-009

010

HB/HS alarm for 1-phase heaters, 4 EV inputs

4

E5_C-QX4A5M-010

E5_C-QX4D5M-010

011

HB/HS alarm for 1-phase heaters, 6 EV inputs, remote SP, transfer output

4

E5_C-QX4A5M-011

E5_C-QX4D5M-011

Out1: Linear current

Out2: non

000

No option

4

E5_C-CX4A5M-000

E5_C-CX4D5M-000

004

2 EV inputs, RS485

4

E5_C-CX4A5M-004

E5_C-CX4D5M-004

014

RS485, 4 EV inputs, remote SP, transfer output

4

E5_C-CX4A5M-014

E5_C-CX4D5M-014

Out1: Relay

Out2: Relay

Positional proportional control model

000

No option

4

E5_C-PR4A5M-000

E5_C-PR4D5M-000

004

2 EV inputs, RS485

4

E5_C-PR4A5M-004

E5_C-PR4D5M-004

014

RS485, 4 EV inputs, remote SP, transfer output

4

E5_C-PR4A5M-014

E5_C-PR4D5M-014

Note: Other models with 2 control outputs or with different kind of option combination are available on request. Please contact the local sales office for special request. Replace “_” with “A” for E5AC or “E” for E5EC

E5EC (48x96mm) Push-in plus terminals

Control Output

Option no

Option description

Alarm outputs

Order code

100 to 240 VAC

24 VAC/DC

Out1: Relay

Out2: non

0

No option

4

E5EC-RX4ABM-000

E5EC-RX4DBM-000

8

HB/HS alarm for 1-phase heaters, RS485, 2 EV inputs

4

E5EC-RX4ABM-008

E5EC-RX4DBM-008

10

HB/HS alarm for 1-phase heaters, 4 EV inputs

4

E5EC-RX4ABM-010

E5EC-RX4DBM-010

11

HB/HS alarm for 1-phase heaters, 6 EV inputs, remote SP, transfer output

4

E5EC-RX4ABM-011

E5EC-RX4DBM-011

Out1: Voltage (pulse) Out2: non

0

No option

4

E5EC-QX4ABM-000

E5EC-QX4DBM-000

8

HB/HS alarm for 1-phase heaters, RS485, 2 EV inputs

4

E5EC-QX4ABM-008

E5EC-QX4DBM-008

10

HB/HS alarm for 1-phase heaters, 4 EV inputs

4

E5EC-QX4ABM-010

E5EC-QX4DBM-010

11

HB/HS alarm for 1-phase heaters, 6 EV inputs, remote SP, transfer output

4

E5EC-QX4ABM-011

E5EC-QX4DBM-011

Note: Other models with 2 Alarm outputs are available on request. Please contact the local sales office for special request.

E5GC (48 × 24 mm)

Control Output

Terminal type

Option no

Option description

Alarm outputs

Order code

100 to 240 VAC

24 VAC/DC

Out1: Relay

Screwless clamp

000

No option

1

E5GC-RX1ACM-000

E5GC-RX1DCM-000

015

RS485

1

E5GC-RX1ACM-015

E5GC-RX1DCM-015

024

2 EV inputs

1

E5GC-RX1ACM-024

E5GC-RX1DCM-024

Out1: Voltage (pulse)

Screwless clamp

000

No option

1

E5GC-QX1ACM-000

E5GC-QX1DCM-000

015

RS485

1

E5GC-QX1ACM-015

E5GC-QX1DCM-015

024

2 EV inputs

1

E5GC-QX1ACM-024

E5GC-QX1DCM-024

Out1: Linear current

Screwless clamp

000

No option

1

E5GC-CX1ACM-000

E5GC-CX1DCM-000

015

RS485

1

E5GC-CX1ACM-015

E5GC-CX1DCM-015

024

2 EV inputs

1

E5GC-CX1ACM-024

E5GC-CX1DCM-024

Note: Other models with screw terminals, 0 or 2 Alarm outputs, 1 Event input or HBA alarm are available on request. Please contact the local sales office for special request.

E5DC (In-panel mounting)

Control Output

Option no

Option description

Alarm outputs

Order code

100 to 240 VAC

24 VAC/DC

Out1: Relay

000

No option

2

E5DC-RX2ASM-000

E5DC-RX2DSM-000

002

HB/HS alarm for 1-phase heaters, RS485

2

E5DC-RX2ASM-002

E5DC-RX2DSM-002

017

HB/HS alarm for 1-phase heaters, 1 EV input

2

E5DC-RX2ASM-017

E5DC-RX2DSM-017

Out1: Voltage (pulse)

000

No option

2

E5DC-QX2ASM-000

E5DC-QX2DSM-000

002

HB/HS alarm for 1-phase heaters, RS485

2

E5DC-QX2ASM-002

E5DC-QX2DSM-002

017

HB/HS alarm for 1-phase heaters, 1 EV input

2

E5DC-QX2ASM-017

E5DC-QX2DSM-017

Out1: Linear current

000

No option

2

E5DC-CX2ASM-000

E5DC-CX2DSM-000

015

RS485

2

E5DC-CX2ASM-015

E5DC-CX2DSM-015

016

1 EV input

2

E5DC-CX2ASM-016

E5DC-CX2DSM-016

Note: Other models with no Alarm output or with different kind of option combination are available on request. Please contact the local sales office for special request.

E5_C optional tools

Option

Order code

USB based configuration cable

E58-CIFQ2, E58-CIFQ2-E (for E5AC, E5DC, E5EC and E5GC)

PC based configuration and tuning software

EST2-2C-MV4

Specifications

E5CC/E5EC/E5AC

Item

E5CC

E5EC

E5AC

Power supply voltage

A in model number: 100 to 240 VAC, 50/60 Hz

D in model number: 24 VAC, 50/60 Hz; 24 VDC

Operating voltage range

85% to 110% of rated supply voltage

Power consumption

6.5 VA max. at 100 to 240 VAC, and
4.1 VA max. at 24 VAC or
2.3 W max. at 24 VDC

8.3 VA max. at 100 to 240 VAC, and
5.5 VA max. at 24 VAC or
3.2 W max. at 24 VDC

9.0 VA max. at 100 to 240 VAC, and
5.6 VA max. at 24 VAC or
3.4 W max. at 24 VDC

Sensor input

  • Temperature inputs
    Thermocouple: K, J, T, E, L, U, N, R, S, B, W, or PL II
    Platinum resistance thermometer: Pt100 or JPt100
    Infrared temperature sensor (ES1B): 10 to 70°C, 60 to 120°C, 115 to 165°C, or 140 to 260°C
  • Analog inputs
    Current input (mA): 4 to 20 or 0 to 20
    Voltage input (V): 1 to 5, 0 to 5, or 0 to 10

Input impedance

Current input: 150 Ω max., Voltage input: 1 MΩ min.

(Use a 1:1 connection when connecting the ES2-HB/THB.)

Control method

ON/OFF control or 2-PID control (with auto-tuning)

Indication accuracy

Thermocouple input: (±0.3% of indicated value or ±1°C, whichever is greater) ±1 digit max.

Platinum resistance thermometer input: (±0.2% of indicated value or ±0.8°C, whichever is greater) ±1 digit max.

Analog input: ±0.2% FS ±1 digit max.

CT input: ±5% FS ±1 digit max.

Thermocouple input: (±0.3% of indicated value or ±1°C, whichever is greater) ±1 digit max.

Platinum resistance thermometer input: (±0.2% of indicated value or ±0.8°C, whichever is greater) ±1 digit max.

Analog input: ±0.2% FS ±1 digit max.

CT input: ±5% FS ±1 digit max.

Potentiometer input: ±5% FS ±1 digit max.

Auto-Tuning

Yes, 40%/100% MV output limit selection. When using Heat/Cool: Automatic cool gain adjustment

Self-Tuning

Yes

Control outputs

Relay output

SPST-NO, 250 VAC, 3 A (resistive load), electrical life: 100,000 operations,
minimum applicable load: 5 V, 10 mA

SPST-NO, 250 VAC, 5 A (resistive load),
electrical life: 100,000 operations,
minimum applicable load: 5 V, 10 mA

Voltage output (for driving SSR)

Output voltage: 12 VDC ±20% (PNP), max. load current: 21 mA, with short-circuit protection circuit

Output voltage: 12 VDC ±20% (PNP),
max. load current: 40 mA, with short-circuit protection circuit

(The maximum load current is 21 mA for models with two control outputs.)

Linear current output

4 to 20 mA DC/0 to 20 mA DC, load: 500 Ω max., resolution: approx. 10,000

Auxiliary outputs

Number of outputs

2,3

4

Output specifications

N.O. relay outputs, 250 VAC,
Models with 3 outputs: 2 A (resistive load), electrical life: 100,000 operations,
minimum applicable load: 5 V, 10 mA

N.O. relay outputs, 250 VAC,
Models with 4 outputs: 2 A (resistive load),
electrical life: 100,000 operations,
minimum applicable load: 5 V, 10 mA

Event inputs

Number of inputs

2 or 4 or 6 max (depends on the model)

External contact input specifications

Contact input: ON: 1 kΩ max., OFF: 100 kΩ min.

Non-contact input: ON: Residual voltage: 1.5 V max., OFF: Leakage current: 0.1 mA max.

Current flow: approx. 7 mA per contact

Setting method

Digital setting using front panel keys or via Remote Software CX-Thermo V4.5

Indication method

11-segment digital display and individual indicators

Multi SP

Up to eight set points (SP0 to SP7) can be saved and selected using event inputs, key operations, or serial communications.

Other functions

Manual output, heating/cooling control, loop burnout alarm, SP ramp, other alarm functions, heater burnout detection (including SSR failure detection), 40% AT, 100% AT, MV limiter, input digital filter, self-tuning, temperature input shift, run/stop, protection functions, extraction of square root, MV change rate limit, logic operations, PV/SV status display, simple program, automatic cooling coefficient adjustment

Ambient operating temperature

-10 to 55°C (with no condensation or icing)

Ambient operating humidity

25% to 85%

Storage temperature

-25 to 65°C (with no condensation or icing)

Degree of protection

Front panel: IP66, Rear case: IP20, Terminals: IP00

Sampling period

50 ms

Size in mm (H×W×D)

48×48×64

48×96×64

96×96×64

E5GC

Item

E5GC

Power supply voltage

A in model number: 100 to 240 VAC, 50/60 Hz

D in model number: 24 VAC, 50/60 Hz; 24 VDC

Sensor input

  • Temperature input
    Thermocouple: K, J, T, E, L, U, N, R, S, B, W, or PL II
    Platinum resistance thermometer: Pt100 or JPt100
    Infrared temperature sensor (ES1B): 10 to 70°C, 60 to 120°C, 115 to 165°C, or 140 to 260°C
  • Analog input
    Current input: 4 to 20 mA or 0 to 20 mA
    Voltage input: 1 to 5 V, 0 to 5 V, or 0 to 10 V

Control method

ON/OFF control or 2-PID control (with auto-tuning)

Control output

Relay output

SPST-NO, 250 VAC, 2 A (resistive load), electrical life: 100,000 operations, minimum applicable load: 5 V, 10 mA (reference value)

Voltage output (for driving SSR)

Output voltage 12 VDC ±20% (PNP), max. Load current: 21 mA, with short-circuit protection circuit

Linear current output

4 to 20 mA DC/0 to 20 mA DC, load: 500 Ω max., resolution: Approx. 10,000

Auxiliary output

Number of outputs

1 or 2 (depends on model)

Output specifications

SPST-NO relay outputs, 250 VAC, 2 A (resistive load),
Electrical life: 100,000 operations, Minimum applicable load: 10 mA at 5 V (reference value)

Indication method

11-segment digital displays and individual indicators
Character height: PV: 10.5 mm, SV: 5.0 mm

Multi SP

Up to eight set points (SP0 to SP7) can be saved and selected using the event inputs, key operations, or serial communications.1

Other functions

Manual output, heating/cooling control, loop burnout alarm, SP ramp, other alarm functions, heater burnout (HB) alarm (including SSR failure (HS) alarm), 40% AT, 100% AT, MV limiter, input digital filter, self tuning, robust tuning, PV input shift, run/stop, protection functions, extraction of square root, MV change rate limit, logic operations, temperature status display, simple programming, moving average of input value, display brightness setting, simple transfer output, and work bit message.2

Size in mm (H×W×D)

24×48×93

E5DC

Item

E5DC

Power supply voltage

A in model number: 100 to 240 VAC, 50/60 Hz

D in model number: 24 VAC, 50/60 Hz; 24 VDC

Operating voltage range

85% to 110% of rated supply voltage

Power consumption

4.9 VA max. at 100 to 240 VAC, and
2.8 VA max. at 24 VDC or
1.5 W max. at 24 VDC

Sensor input

  • Temperature inputs
    Thermocouple: K, J, T, E, L, U, N, R, S, B, W, or PL II
    Platinum resistance thermometer: Pt100 or JPt100
    Infrared temperature sensor (ES1B): 10 to 70°C, 60 to 120°C, 115 to 165°C, or 140 to 260°C
  • Analog inputs
    Current input (mA): 4 to 20 or 0 to 20
    Voltage input (V): 1 to 5, 0 to 5, or 0 to 10

Input impedance

Current input: 150 Ω max., Voltage input: 1 MΩ min. (Use a 1:1 connection when connecting the ES2-HB/THB.)

Control method

ON/OFF control or 2-PID control (with auto-tuning)

Indication accuracy

Thermocouple input: (±0.3% of PV or ±1°C, whichever is greater) ±1 digit max.

Platinum resistance thermometer input: (±0.2% of PV or ±0.8°C, whichever is greater) ±1 digit max.

Analog input: ±0.2% FS ±1 digit max.

CT input: ±5% FS ±1 digit max.

Auto-Tuning

Yes, 40%/100% MV output limit selection. When using Heat/Cool: Automatic cool gain adjustment

Self-Tuning

Yes

Control outputs

Relay output

SPST-NO, 250 VAC, 3 A (resistive load), electrical life: 100,000 operations, minimum applicable load: 5 V, 10 mA

Voltage output (for driving SSR)

Output voltage: 12 VDC ±20% (PNP), max. load current: 20 mA, with short-circuit protection circuit

Linear current output

4 to 20 mA DC/0 to 20 mA DC, load: 500 Ω max., resolution: approx. 10,000

Auxiliary outputs

Number of outputs

2 (depends on model)

Output specifications

SPST-NO relay outputs: 250 VAC, 2 A (resistive load),
Electrical life: 100,000 operations, minimum applicable load: 5 V, 10 mA

Event inputs

Number of inputs

1 (depends on model)

External contact input specifications

Contact input: ON: 1 kΩ max., OFF: 100 kΩ min.

Non-contact input: ON: Residual voltage: 1.5 V max., OFF: Leakage current: 0.1 mA max.

Current flow: approx. 7 mA per contact

Setting method

Digital setting using front panel keys

Indication method

11-segment digital displays and individual indicators
Character height: PV 8.5 mm, SV: 8.0 mm

Multi SP

Up to eight set points (SP0 to SP7) can be saved and selected using event inputs, key operations, or serial communications.3

Other functions

Manual output, heating/cooling control, loop burnout alarm, SP ramp, other alarm functions, heater burnout (HB) alarm (including SSR failure (HB) alarm), 40% AT, 100% AT, MV limiter, input digital filter, self tuning, robust tuning, PV input shift, run/stop, protection functions, extraction of square root, MV change rate limit, simple calculations, temperature status display, simple programming, moving average of input value, and display brightness setting

Ambient operating temperature

-10 to 55°C (with no condensation or icing), for 3-year warranty: -10 to 50°C (with no condensation or icing)

Ambient operating humidity

25% to 85%

Storage temperature

-25 to 65°C (with no condensation or icing)

Degree of protection

Main unit: IP20, Terminal unit: IP00

Sampling period

50 ms

Size in mm (H×W×D)

96×22.5×85

USB communication cable E58-CIFQ2

Item

E5AC

E5CC

E5DC

E5EC

E5GC

E58-CIFQ2

¢

¢

¢

¢

¢

E58-CIFQ2-E

¢

-

¢

¢

¢

 


1. Only four set points are selectable for event inputs.

2. Simple transfer output and work bit message are only for E5GC.

3. Only two set points are selectable for event inputs.

1. Only four set points are selectable for event inputs.

2. Simple transfer output and work bit message are only for E5GC.

3. Only two set points are selectable for event inputs.

Software

CX-Thermo

CX-Thermo_no_version .jpg
CX-Thermo enables faster parameter set-up, easier device adjustment and simpler maintenance. It dramatically reduces the time and effort needed to set and manage temperature control parameters, providing advanced creating, editing and batch-downloading functions.

CX-One

CX-One_Screen
CX-One software allows users to build, configure and program a host of devices such as PLCs, HMIs and motion-control systems and networks using just one software package with one installation and license number. This greatly reduces the complexity of the configuration and allows automation systems to be programmed or configured with minimal training.
Publications

Introducing our new E5AC ¼ DIN size temperature controllers

E5_C_line-up_400x400.jpg
With the introduction of our ¼ DIN size (96 x 96mm) E5AC temperature controller, the E5_C family goes from strength to strength with more added functionality and application variety.

New DIN-rail format temperature controller - only 22.5mm wide

E5_C Series.jpg
We have launched another attractive and multi-functional temperature controller in DIN-rail format with removable socket. The E5DC single loop controller is only 22.5mm wide and follows the outstanding control performance of the E5_C temperature control series with 50ms of control loop update time.
Downloads

Brochures

Show all brochures

Datasheets

Show all datasheets

Manuals

Show all manuals

Software tools

download

Thermac Temperature Simulation Software

en ZIP 16.2 MB
o

Please or get direct access to download this document

Show all software tools

TechNotes

Show all technotes

Have a question?

We are ready to help.

Contact us

Subscribe to product updates

Newsletters about product innovations, solutions and services, directly in your inbox.

Thank you for subscribing to Omron's eNews. You will shortly receive an e-mail from us. This e-mail contains a link which activates your email newsletter subscription. This method is used due to legal issues and to make certain that no-one can abuse your e-mail address.

We are experiencing technical difficulties. Your form submission has not been successful. Please accept our apologies and try again later. Details: [details]

Download

Product documentation

Download datasheets, manuals and brochures.

Browse download center

Training courses

Get the training from our best engineers. Beginner to advanced level.

View training courses