DRT2-*C*

Features

IP67 DeviceNet I/O

Rugged I/O units for field mounting. The DRT2 slave units feature internal diagnostic and maintenance data collection, which can be accessed over the network. Power supply status, I/O response times, operation counters and on-time monitor data is available at all times, and is internally checked against user-defined limits. Maintenance warnings will be generated when limits are exceeded. Using CX-One or NS-series HMI with Smart Active Parts for visualisation, this allows more efficient system setup, commissioning and troubleshooting without any additional programming.

  • IP67 protection, DRT2 versions are also oil- and welding-spatter proof
  • Internal circuits powered by DeviceNet; fewer connections means less installation errors
  • Smart Slave functions for diagnostics and preventive maintenance
  • Indication of broken wire and short-circuit in I/O signals
  • M12 connectors for fast installation

Harsh environment

The I/O units for tough environments

Resistant against dust, water and welding spatters. IP67 I/O units are aimed at providing maximum availability under all circumstances.

Network

DeviceNet: Fault-tolerant

Availability guaranteed no matter how tough the environmental circumstances are. DeviceNet is based on proven CAN technology.

I/O Wiring

Fault-free wiring

Rugged, M12 prefabricated cable-connector assemblies provide fast and faultless installation.

Cables

One cable for power and data

Power supply through DeviceNet cable with rugged M12, prefabricated cable-connector assemblies.

Smart features

All Omron I/O units have built-in Smart Features that help to:
  • Reduce engineering time
  • Plan preventative maintainance
  • Increase your productivity
Take a look at one of the features below for a demonstration.

Calendar

Smart I/O can store the last date on which you performed maintenance. A better overview will help you plan maintenance more efficiently.

Counter

Smart I/O units all keep track of duration and number of operations, to help you plan machine maintenance. Timely warnings to inspect and adjust the machine will minimise unplanned downtime.

Volt meter

Smart I/O monitors its own supply voltage, and will warn you if the voltage is out of safe range - e.g. due to damaged cable or poor connection.

Stopwatch

Smart I/O can measure delays between two I/O signals with millisecond accuracy. When your preset limit is exceeded, Smart I/O will warn you that wear or lack of lubrication has reduced machine performance.

Calculator

Smart Analog I/O performs data pre-processing to help you reduce PLC programming. Scaling and alarms, and even totalising or rate-of-change calculations are handled inside the unit.
Specifications & ordering info

Ordering information

Unit type

Specifications

Size in mm (H×W×D)

Remarks

Order code

4-point PNP input unit

24 V, 6 mA

123×60×44

Separate I/O power supply connection

DRT2-ID04CL-1

8-point PNP input unit

24 V, 6 mA

175×60×44

Separate I/O power supply connection

DRT2-ID08CL-1

8-point PNP input unit

24 V, 11 mA, with power short-circuit and sensor disconnection detection

175×60×38

Unit power supply via DeviceNet cable

DRT2-ID08C-1

16-point PNP input unit

24 V, 6 mA, 2 inputs per M12 connector

175×60×44

Separate I/O power supply connection

DRT2-HD16CL-1

16-point PNP input unit

24 V, 11 mA, 2 inputs per M12 connector,
with power short-circuit and sensor disconnection detection

175×60×38

Unit power supply via DeviceNet cable

DRT2-HD16C-1

4-point PNP output unit

24 V, 0.5 A per point

123×60×44

Separate I/O power supply connection

DRT2-OD04CL-1

8-point PNP output unit

24 V, 0.5 A per point

175×60×44

Separate I/O power supply connection

DRT2-OD08CL-1

8-point PNP output unit

24 V, 1.5 A per point (8 A total), with short-circuit protection + indication

175×60×44

Separate I/O power supply connection

DRT2-OD08C-1

16-point PNP output unit

24 V, 0.5 A per point, 2 points per M12 connector

175×60×44

Separate I/O power supply connection

DRT2-WD16CL-1

8-point input + 8-point PNP output unit

24 V, 6 mA input, 0.5 A output per point, 2 points per M12 connector

175×60×44

Separate I/O power supply connection

DRT2-MD16CL-1

Note: To order models with NPN (sinking) outputs and corresponding inputs (+V common), omit the “-1” from the model code.

Accessories

Unit type

Specifications

Order code

DeviceNet thin cable

with one M12 socket connector (female), 1 m

DCA1-5CN01F1

DeviceNet thin cable

with one M12 socket connector (female), 2 m

DCA1-5CN02F1

DeviceNet thin cable

with one M12 socket connector (female), 5 m

DCA1-5CN05F1

DeviceNet thin cable

with one M12 socket connector (female) and one M12 plug connector (male), 1 m

DCA1-5CN01W1

DeviceNet thin cable

with one M12 socket connector (female) and one M12 plug connector (male), 2 m

DCA1-5CN02W1

DeviceNet thin cable

with one M12 socket connector (female) and one M12 plug connector (male), 5 m

DCA1-5CN05W1

DeviceNet T-connector for thin cable

with two M12 socket connectors (female) + one M12 plug connector (male)

DCN2-1

DeviceNet terminator

with M12 plug connector

DRS2-1

Power supply cable

with one 7/8 inches socket connector (female), 2 m

XS4F-D421-102-A

Power supply cable

with one 7/8 inches socket connector (female), 5 m

XS4F-D421-105-A

Power supply cable

with one 7/8 inches socket connector (female) and one 7/8 inches plug connector (male), 2 m

XS4W-D421-102-A

Power supply cable

with one 7/8 inches socket connector (female) and one 7/8 inches plug connector (male), 5 m

XS4W-D421-105-A

Power supply T-connector

with two 7/8 inches socket connectors (female) + one 7/8 inches plug connector (male)

XS4R-D424-5

4-wire I/O connection cable

with one M12 plug connector (male), 1 m

XS2H-D421-C80-A

4-wire I/O connection cable

with one M12 plug connector (male), 2 m

XS2H-D421-D80-A

4-wire I/O connection cable

with one M12 plug connector (male), 5 m

XS2H-D421-G80-A

4-wire I/O connection cable

with one M12 socket connector (female) and one M12 plug connector (male), 1 m

XS2W-D421-C81-A

4-wire I/O connection cable

with one M12 socket connector (female) and one M12 plug connector (male), 2 m

XS2W-D421-D81-A

4-wire I/O connection cable

with one M12 socket connector (female) and one M12 plug connector (male), 5 m

XS2W-D421-G81-A

Y-connector for 16-point I/O units

Splits the 2 I/O points per M12 connector to two M12 connectors

XS2R-D426-1

Y-connector cable for 16-point I/O units

Splits the 2 I/O points per M12 connector to two M12 connectors, 1 m

XS2R-D426-C11-F

M12 connector

M12 plug connector (male), solder type

XS2G-D421

M12 connector

M12 socket connector (female), solder type

XS2C-D421

IP67 cap for M12 sockets

Metal cap for unused I/O connections

XS2Z-12

Software

CX-One

CX-One_Screen
CX-One software allows users to build, configure and program a host of devices such as PLCs, HMIs and motion-control systems and networks using just one software package with one installation and license number. This greatly reduces the complexity of the configuration and allows automation systems to be programmed or configured with minimal training.

Have a question?

We are ready to help.

Contact us

Subscribe to product updates

Newsletters about product innovations, solutions and services, directly in your inbox.

Thank you for subscribing to Omron's eNews. You will shortly receive an e-mail from us. This e-mail contains a link which activates your email newsletter subscription. This method is used due to legal issues and to make certain that no-one can abuse your e-mail address.

We are experiencing technical difficulties. Your form submission has not been successful. Please accept our apologies and try again later. Details: [details]

Download

Product documentation

Download datasheets, manuals and brochures.

Browse download center

Training courses

Get the training from our best engineers. Beginner to advanced level.

View training courses