Login

Please use more than 6 characters. Forgot your password? Click here to reset.

Change password

We are experiencing technical difficulties. Your form submission has not been successful. Please accept our apologies and try again later. Details: [details]

Download

Register

Text error notification

Text error notification

Checkbox error notification

Checkbox error notification

We are experiencing technical difficulties. Your form submission has not been successful. Please accept our apologies and try again later. Details: [details]

Download

Thank you for registering

An email to complete your account has been sent to

Return to the website

get direct access

Fill in your details below and get direct access to view content

Text error notification

Text error notification

Checkbox error notification

Checkbox error notification

We are experiencing technical difficulties. Your form submission has not been successful. Please accept our apologies and try again later. Details: [details]

Download

Thank you for your interest

You now have access to CS Analog and Process I/O Units

A confirmation email has been sent to

Continue to page

CS Analog and Process I/O Units

Features

From basic analogue I/O to process control

CS1 offers a wide choice of analogue input units, fit for any application, from low-speed, multi-channel temperature measurement to high-speed, high-accuracy data acquisition. Analogue outputs can be used for accurate control or external indication.

Advanced units with built-in scaling, filtering and alarm functions reduce the need for complex PLC programming. High-accuracy process I/O units support an extensive range of sensors, for fast and accurate data acquisition. All Process and temperature I/O units provide isolation between all individual channels.

Specifications & ordering info

Ordering information

Points

Type

Ranges

Resolution

Accuracy1

Conversion
time

Remarks

Connection type

Order code

4

Analog input

0 to 5 V,
0 to 10 V,
-10 to 10 V,
1 to 5 V,
4 to 20 mA

1/8,000

V: 0.2% of PV
I: 0.4% of PV

250 µs/point

Offset/gain adjustment, peak hold,
moving average, alarms

M3

CS1W-AD041-V1

8

Analog input

M3

CS1W-AD081-V1

16

Analog input

0.2% of PV

2 × MIL (34p.)

CS1W-AD161

4

Analog output

0 to 5 V,
0 to 10 V,
-10 to 10 V,
1 to 5 V,
4 to 20 mA

1/4,000

V: 0.3% of PV
I: 0.5% of PV

1 ms/point

Offset/gain adjustment

M3

CS1W-DA041

8

Voltage output

0 to 5 V,
0 to 10 V,
-10 to 10 V,
1 to 5 V

0.3% of PV

Offset/gain adjustment, output hold

M3

CS1W-DA08V

8

Current output

4 to 20 mA

0.5% of PV

M3

CS1W-DA08C

4 + 4

Analog in + output

0 to 5 V,
0 to 10 V,
-10 to 10 V,
1 to 5 V
(4 to 20 mA input)

1/8,000

V in: 0.2% of PV
I in: 0.4% of PV
out: 0.3% of PV

1 ms/point

Offset/gain adjustment, scaling, peak hold, moving average, alarms, output hold

M3

CS1W-MAD44

4

Process input

4 to 20 mA,
0 to 20 mA,
0 to 10 V,
-10 to 10 V,
0 to 5 V,
-5 to 5 V,
1 to 5 V,
1 to 1.25 V,
-1.25 to 1.25 V

1/64,000

0.05% of PV

5 ms/point

Configurable alarms, maintenance
functions, user-defined scaling, zero/span adjustment, square root, totaliser.

M3

CS1W-PDC11

8

Process input

-10 to 10 V,
0 to 5 V,
1 to 5 V,
4 to 20 mA

1/16,000

0.3% of PV

62.5 ms/point

Configurable alarms, zero/span adjustment, square root

M3

CS1W-PDC55

4

Thermocouple input

B, E, J, K, L, N, R, S, T,
U, WRe5-26, PLII,
-100 to 100 mV

1/64,000

0.05% of PV

5 ms/point

Configurable alarms (absolute +
rate-of-change), peak hold,
maintenance functions

M3

CS1W-PTS11

4

Resistance thermometer input

Pt50, Pt100 JPt100, Ni508.4

1/64,000

0.05% of PV

5 ms/point

Configurable alarms (absolute +
rate-of-change), peak hold,
maintenance functions

M3

CS1W-PTS12

4

Thermocouple input

B, J, K, L, R, S, T

0.1°C

0.3% of PV

62.5 ms/point

4 configurable alarm outputs

M3

CS1W-PTS51

4

Resistance thermometer input

Pt100, JPt100

0.1°C

0.3% of PV

62.5 ms/point

4 configurable alarm outputs

M3

CS1W-PTS52

8

Thermocouple input

B, J, K, L, R,S, T

0.1°C

0.3% of PV

31.2 ms/point

Configurable alarms per channel

M3

CS1W-PTS55

8

Resistance thermometer input

Pt100, JPt100

0.1°C

0.3% of PV

31.2 ms/point

Configurable alarms per channel

M3

CS1W-PTS56

4

2-Wire transmitter input

1 to 5 V,
4 to 20 mA

1/4,096

0.2% of FS

25 ms/point

Built-in power supply for transmitter, configurable alarms, square root,
rate-of-change, etc.

M3

CS1W-PTW01

8

Power transducer input

-1 to 1 mA,
0 to 1 mA

1/4,096

0.2% of FS

25 ms/point

Inrush current limiter, configurable alarms, averaging, etc.

M3

CS1W-PTR01

8

Power transducer input

-100 to 100 mV,
0 to 100 mV

1/4,096

0.2% of FS

25 ms/point

Inrush current limiter, configurable alarms, averaging, etc.

M3

CS1W-PTR02

4

Pulse rate input

20000 pps, voltage,
open collector, contact

up to
1/32,000

-

25 ms/point

Averaging, totaliser

M3

CS1W-PPS01

4

Isolated control output

1 to 5 V,
4 to 20 mA

1/4,000

I: 0.1% of FS
V: 0.2% of FS

25 ms/point

Output readback, high/low/rate limiting, disconnection alarm, zero/span
adjustment

M3

CS1W-PMV01

4

Isolated control output

-10 to 10 V,
0 to 10 V,
-5 to 5 V,
0 to 5 V,
-1 to 1 V,
0 to 1 V

1/4,000

0.1% of FS

10 ms/point

High/low/rate limiting, output hold,
zero/span adjustment

M3

CS1W-PMV02

Note: All analog I/O units are designated as special I/O units


1. Accuracy for Voltage and Current Inputs/Outputs as percentage of full scale and typical value at 25°C ambient temperature (Consult the operation manual for details)
Accuracy for Temperature Inputs/Outputs as percentage of process value and typical value at 25°C ambient temperature (Consult the operation manual for details)

1. Accuracy for Voltage and Current Inputs/Outputs as percentage of full scale and typical value at 25°C ambient temperature (Consult the operation manual for details)
Accuracy for Temperature Inputs/Outputs as percentage of process value and typical value at 25°C ambient temperature (Consult the operation manual for details)

Downloads

Brochures

Show all brochures

Catalogues

Show all catalogues

Manuals

Show all manuals

Have a question?

We are ready to help.

Contact us

Subscribe to product updates

Newsletters about product innovations, solutions and services, directly in your inbox.

Thank you for subscribing to Omron's eNews. You will shortly receive an e-mail from us. This e-mail contains a link which activates your email newsletter subscription. This method is used due to legal issues and to make certain that no-one can abuse your e-mail address.

We are experiencing technical difficulties. Your form submission has not been successful. Please accept our apologies and try again later. Details: [details]

Download

Product documentation

Download datasheets, manuals and brochures.

Browse download center

Training courses

Get the training from our best engineers. Beginner to advanced level.

View training courses