Login

Please use more than 6 characters. Forgot your password? Click here to reset.

Change password

We are experiencing technical difficulties. Your form submission has not been successful. Please accept our apologies and try again later. Details: [details]

Download

Register

Text error notification

Text error notification

Checkbox error notification

Checkbox error notification

We are experiencing technical difficulties. Your form submission has not been successful. Please accept our apologies and try again later. Details: [details]

Download

Thank you for registering

An email to complete your account has been sent to

Return to the website

get direct access

Fill in your details below and get direct access to view content

Text error notification

Text error notification

Checkbox error notification

Checkbox error notification

We are experiencing technical difficulties. Your form submission has not been successful. Please accept our apologies and try again later. Details: [details]

Download

Thank you for your interest

You now have access to V1000

A confirmation email has been sent to

Continue to page

V1000

  • VZ-series V1000 Variable Frequency Drive Datasheet
  • Thank you for downloading the VZ-series V1000 Variable Frequency Drive Datasheet

    Download again

    Did you know that 4 out of 5 distributors buy this product in a bundle?

    There are many variations of passages of Lorem Ipsum available, but the majority have suffered alteration in some form, by injected humour, or randomised words which don't look even slightly believable.

    Read more
Features

10 x 100 = 1 - Quality has a new formula, 10 year life-time without maintenance.

Thanks to the patented design of the V1000 series (VZA) and modern manufacturing, it is built for a 10 year life-time without maintenance. The new features guarantee a 100% expectation match and with a field failure rate of less than 1 in 10,000, the new V1000 series inverter will outperform all other inverters long after it has been implemented.

  • Up to 15kW / 18.5kW
  • Built-in filter
  • Current vector control
  • IM and PM motor control
  • Embedded safety stop function Category 3 (EN954-1)
Specifications & ordering info

Ordering information

 

V1000

Specifications

Order code

 

Heavy Duty

Normal Duty

Standard

Built-in filter

1x200 V

0.12 kW

0.8 A

0.18 kW

0.8 A

VZAB0P1BAA

VZAB0P1EAA

0.25 kW

1.6 A

0.37 kW

1.6 A

VZAB0P2BAA

VZAB0P2EAA

0.55 kW

3.0 A

0.75 kW

3.5 A

VZAB0P4BAA

VZAB0P4EAA

1.1 kW

5.0 A

1.1 kW

6.0 A

VZAB0P7BAA

VZAB0P7EAA

1.5 kW

8.0 A

2.2 kW

9.6 A

VZAB1P5BAA

VZAB1P5EAA

2.2 kW

11.0 A

3.0 kW

12.0 A

VZAB2P2BAA

VZAB2P2EAA

4.0 kW

17.5 A

5.5 kW

21.0 A

VZAB4P0BAA

-

3x200 V

0.12 kW

0.8 A

0.18 kW

0.8 A

VZA20P1BAA

-

0.25 kW

1.6 A

0.37 kW

1.6 A

VZA20P2BAA

-

0.55 kW

3.0 A

0.75 kW

3.5 A

VZA20P4BAA

-

1.1 kW

5.0 A

1.1 kW

6.0 A

VZA20P7BAA

-

1.5 kW

8.0 A

2.2 kW

9.6 A

VZA21P5BAA

-

2.2 kW

11.0 A

3.0 kW

12.0 A

VZA22P2BAA

-

4.0 kW

17.5 A

5.5 kW

21.0 A

VZA24P0BAA

-

5.5 kW

25.0 A

7.5 kW

30.0 A

VZA25P5FAA

-

7.5 kW

33.0 A

11.0 kW

40.0 A

VZA27P5FAA

-

11 kW

47.0 A

15.0 kW

56.0 A

VZA2011FAA

-

15 kW

60.0 A

18.5 kW

69.0 A

VZA2015FAA

-

3x400 V

0.37 kW

1.2 A

0.37 kW

1.2 A

VZA40P2BAA

VZA40P2EAA

0.55 kW

1.8 A

0.75 kW

2.1 A

VZA40P4BAA

VZA40P4EAA

1.1 kW

3.4 A

1.5 kW

4.1 A

VZA40P7BAA

VZA40P7EAA

1.5 kW

4.8 A

2.2 kW

5.4 A

VZA41P5BAA

VZA41P5EAA

2.2 kW

5.5 A

3.0 kW

6.9 A

VZA42P2BAA

VZA42P2EAA

3.0 kW

7.2 A

4.0 kW

8.8 A

VZA43P0BAA

VZA43P0EAA

4.0 kW

9.2 A

5.5 kW

11.1 A

VZA44P0BAA

VZA44P0EAA

5.5 kW

14.8 A

7.5 kW

17.5 A

VZA45P5FAA

-

7.5 kW

18.0 A

11.0 kW

23.0 A

VZA47P5FAA

-

11 kW

24.0 A

15.0 kW

31.0 A

VZA4011FAA

-

15 kW

31.0 A

18.5 kW

38.0 A

VZA4015FAA

-

Line filters

Inverter

Standard line filter

Low leakage line filter

Schaffner

Rasmi

Schaffner

Rasmi

Voltage

Model VZA☐

Reference

A1000-FIV

Current (A)

Reference

A1000-FIV

Current (A)

Reference

A1000-FIV

Current (A)

Reference

A1000-FIV

Current (A)

1-Phase

200 VAC

B0P1 / B0P2 / B0P4

1010-SE

10

1010-RE

10

1010-SE-LL

10

1010-RE-LL

10

B0P7 / B1P5

1020-SE

20

1020-RE

20

1020-SE-LL

20

1020-RE-LL

20

B2P2

1030-SE

30

1030-RE

30

1030-SE-LL

24

1030-RE-LL

30

B4P0

1040-SE

40

1040-RE

40

1040-SE-LL

40

1040-RE-LL

40

3-Phase

200 VAC

20P1 / 20P2 / 20P4 / 20P7

2010-SE

8

2010-RE

10

2010-SE-LL

10

2010-RE-LL

10

21P5 / 22P2

2020-SE

14

2020-RE

16

2020-SE-LL

20

2020-RE-LL

16

24P0

2030-SE

24

2030-RE

26

2030-SE-LL

30

2030-RE-LL

26

25P5 / 27P5

2060-SE

52

2060-RE

60

-

-

2060-RE-LL

60

2011

2080-SE

68

2080-RE

80

-

-

2080-RE-LL

80

2015

2100-SE

80

2100-RE

100

-

-

2100-RE-LL

100

3-Phase

400 VAC

40P2 / 40P4

3005-SE

5

3005-RE

5

3005-SE-LL

5

3005-RE-LL

5

40P7 / 41P5 / 42P2 / 43P0

3010-SE

10

3010-RE

10

3010-SE-LL

10

3010-RE-LL

10

44P0

3020-SE

15

3020-RE

15

3020-SE-LL

15

3020-RE-LL

15

45P5 / 47P5

3030-SE

30

3030-RE

30

3030-SE-LL

30

3030-RE-LL

30

4011 / 4015

3050-SE

50

3050-RE

50

3050-SE-LL

50

3050-RE-LL

50

Input AC reactors

Inverter

AC Reactor

Voltage

Model VZA

Reference

1-Phase 200 VAC

B0P1 / B0P2 / B0P4

AX-RAI02000070-DE

B0P7

AX-RAI01700140-DE

B1P5

AX-RAI01200200-DE

B2P2

AX-RAI00630240-DE

B4P0

-

3-Phase 200 VAC

20P1 / 20P2 / 20P4 / 20P7

AX-RAI02800080-DE

21P5 / 22P2 / 24P0

AX-RAI00880200-DE

25P5 / 27P5

AX-RAI00350335-DE

2011 / 2015

AX-RAI00180670-DE

3-Phase 400 VAC

40P2 / 40P4 / 40P7 / 41P5

AX-RAI07700050-DE

42P2 / 43P0 / 44P0

AX-RAI03500100-DE

45P5 / 47P5

AX-RAI01300170-DE

4011 / 4015

AX-RAI00740335-DE

DC reactors

200V 1-phase

200V 3-phase

400V 3-phase

Model VZA

DC Reactor

Model VZA

DC Reactor

Model VZA

DC Reactor

B0P1

AX-RC10700032-DE

20P1

AX-RC21400016-DE

40P2 / 40P4

AX-RC43000020-DE

B0P2

20P2

40P7

AX-RC27000030-DE

B0P4

AX-RC06750061-DE

20P4

AX-RC10700032-DE

41P5

AX-RC14000047-DE

B0P7

AX-RC03510093-DE

20P7

AX-RC06750061-DE

42P2

AX-RC10100069-DE

B1P5

AX-RC02510138-DE

21P5

AX-RC03510093-DE

43P0

AX-RC08250093-DE

B2P2

AX-RC01600223-DE

22P2

AX-RC02510138-DE

44P0

AX-RC06400116-DE

B4P0

-

24P0

AX-RC01600223-DE

45P5

AX-RC04410167-DE

-

25P5

AX-RC01110309-DE

47P5

AX-RC03350219-DE

27P5

AX-RC00840437-DE

4011

AX-RC02330307-DE

2011

AX-RC00590614-DE

4015

AX-RC01750430-DE

2015

AX-RC00440859-DE

-

Chokes

Model

Diameter

Description

AX-FER2102-RE

21

For 2.2 KW motors or below

AX-FER2515-RE

25

For 15 KW motors or below

AX-FER5045-RE

50

For 45 KW motors or below

Output AC reactor

Inverter

AC Reactor

Voltage

Model VZA

Reference

200 VAC

B0P1 / B0P2 / B0P4

20P1 / 20P2 / 20P4

AX-RAO11500026-DE

B0P7 / 20P7

AX-RAO07600042-DE

B1P5 / 21P5

AX-RAO04100075-DE

B2P2 / 22P2

AX-RAO03000105-DE

B4P0 / 24P0

AX-RAO01830160-DE

25P5

AX-RAO01150220-DE

27P5

AX-RAO00950320-DE

2011

AX-RAO00630430-DE

2015

AX-RAO00490640-DE

400 VAC

40P2 / 40P4 / 40P7 / 41P5

AX-RAO16300038-DE

42P2

AX-RAO11800053-DE

43P0 / 44P0

AX-RAO07300080-DE

45P5

AX-RAO04600110-DE

47P5

AX-RAO03600160-DE

4011

AX-RAO02500220-DE

4015

AX-RAO02000320-DE

Communication cards

Type

Description

Function

Order code

Communication option board

DeviceNet option card

Used for running or stopping the inverter, setting or referencing parameters, and monitoring output frequency, output current, or similar items through DeviceNet communication with the host controller.

SI-N3/V

PROFIBUS-DP option card

Used for running or stopping the inverter, setting or referencing parameters, and monitoring output frequency, output current, or similar items through PROFIBUS-DP communication with the host controller.

SI-P3/V

CANopen option card

Used for running or stopping the inverter, setting or referencing parameters, and monitoring output frequency, output current, or similar items through CANopen communication with the host controller.

SI-S3/V

MECHATROLINK-II option card

Used for running or stopping the inverter, setting or referencing parameters, and monitoring output frequency, output current, or similar items through MECHATROLINK-II communication with the host controller.

SI-T3/V

EtherCAT option card

Used for running or stopping the inverter, setting or referencing parameters, and monitoring output frequency, output current, or similar items through EtherCAT communication with the host controller.

EUOP-SI-ES3/V

PROFINET option card

Used for running or stopping the inverter, setting or referencing parameters, and monitoring output frequency, output current, or similar items through PROFINET communication with the host controller.

SI-EP3/V

Accessories

Types

Description

Functions

Order code

Digital operator

LCD remote operator

LCD Display operator with language support

JVOP-180

Remote operator cable

3 meters cable for connecting remote operator

A1000-CAVOP300-EE

Accessories

USB converter / USB cable

USB converter unit with copy and backup function

JVOP-181

24 VDC option board

24VDC control board power supply VZA-B/2/4 from 0.1 to 4 KW

PS-V10S

24VDC control board power supply VZA-2/4 from 5.5 to 15 KW

PS-V10M

PC connection cable

RS232 PC tool connection cable

A1000-CAVPC232-EE

Computer software

Types

Description

Installation

Order code

Software

Computer software

Configuration and monitoring software tool

CX-Drive

Computer software

Configuration and monitoring software tool

CX-One

Braking unit, braking resistor unit

Inverter

Braking resistor unit

Voltage

Max.
motor kW

Inverter model VZA☐

Connectable min.

resistance Ω

Inverter mounted type

(3 %ED, 10 sec max)

Braking

torque %

1-phase

3-phase

Type AX-

Resist Ω

200 V
(single-/

three-phase)

0.12

B0P1

20P1

300

REM00K1400-IE

400

135

0.25

B0P2

20P2

120

0.55

B0P4

20P4

200

REM00K1200-IE

200

120

1.1

B0P7

20P7

120

70

1.5

B1P5

21P5

60

REM00K2070-IE

70

190

2.2

B2P2

22P2

120

4.0

B4P0

24P0

32

REM00K4035-IE

35

135

5.5

-

25P5

16

75

7.5

-

27P5

9.6

55

11

-

2011

REM00K6035-IE

35

40

15

-

2015

REM00K9017-IE

17

55

400 V
(three-phase)

0.37

-

40P2

750

2 x REM00K1400-IE

800

270

0.55

-

40P4

270

1.1

-

40P7

510

270

1.5

-

41P5

240

REM00K1400-IE

400

130

2.2

-

42P2

200

REM00K2200-IE

200

130

3.0

-

43P0

100

REM00K2120-IE

120

215

4.0

-

44P0

160

5.5

-

45P5

32

REM00K4035-IE

35

140

7.5

-

47P5

80

11

-

4011

20

REM00K6035-IE

35

50

15

-

4015

REM00K9020-IE

20

55

Mounting accessories

Types

Description

Applicable models VZA

Order code

DIN Rail

Necessary to mount the inverter on a DIN rail

B0P1/B0P2/B0P4

20P1/20P2/20P4/20P7

EZZ08122A

B0P7/B1P5

21P5/22P2

40P2/40P4/40P7/41P5/42P2

EZZ08122B

B2P2

24P0

44P0

EZZ08122C

B4P0

EZZ08122D

Heatsink
external mounting attachment

Additional items to mount the inverter with the heatsink out of the panel

B0P1/B0P2

20P1/20P2

100-034-075

B0P4

20P4

100-034-076

20P7

100-034-077

40P2

100-034-078

B1P5

21P5/22P2

41P5/42P2/43P0

100-034-079

B2P2

24P0

44P0

100-034-080

B4P0

100-036-357

B0P7

40P2/40P4

100-036-418

25P5/27P5

45P5/47P5

100-036-300

2011

4011/4015

100-036-301

2015

100-036-302

Specifications

200 V class

Single-phase: VZA☐

B0P1

B0P2

B0P4

B0P7

B1P5

B2P2

B4P01

-

-

-

-

Three-phase: VZA☐

20P1

20P2

20P4

20P7

21P5

22P2

24P0

25P5

27P5

2011

2015

Motor kW2

For HD setting

0.12

0.25

0.4

1.1

1.5

2.2

4.0

5.5

7.5

11

15

For ND setting

0.18

0.37

0.55

1.1

2.2

3.0

5.51

7.5

11

15

18.5

Output
characteristics

Inverter capacity kVA

0.3

0.6

1.1

1.9

3.0

4.2

6.7

9.5

13

18

23

Rated output current (A) at HD

0.8

1.6

3.0

5.0

8.0

11.0

17.5

25.0

33.0

47.0

60.0

Rated output current (A) at ND

1.2

1.9

3.5

6.0

9.6

12.0

19.6

30.0

40.0

56.0

69.0

Max. output voltage

Proportional to input voltage: 0..240 V

Max. output frequency

400 Hz

Power
supply

Rated input voltage
and frequency

Single-phase 200..240 V 50/60 Hz

3-phase 200..240 V 50/60 Hz

Allowable voltage
fluctuation

-15%..+10%

Allowable frequency
fluctuation

+5%

400 V class

Three-phase: VZA☐

40P2

40P4

40P7

41P5

42P2

43P0

44P0

45P5

47P5

4011

4015

Motor kW3

For HD setting

0.37

0.55

1.10

1.5

2.2

3.0

4.0

5.5

7.5

11

15

For ND setting

0.37

0.75

1.5

2.2

3.0

4.0

5.5

7.5

11

15

18.5

Output
characteristics

Inverter capacity kVA

0.9

1.4

2.6

3.7

4.2

5.5

7.2

9.2

14.8

18

24

Rated output current (A) at HD

1.2

1.8

3.4

4.8

5.5

7.2

9.2

14.8

18.0

24

31

Rated output current (A) at ND

1.2

2.1

4.1

5.4

6.9

8.8

11.1

17.5

23

31

38

Max. output voltage

0..480 V (proportional to input voltage)

Max. output frequency

400 Hz

Power
supply

Rated input voltage
and frequency

3-phase 380..480 VAC, 50/60 Hz

Allowable voltage
fluctuation

-15%..+10%

Allowable frequency
fluctuation

+5%

Dimensions

IP20 type

 

Voltage class

Max. applicable
motor output kW

Inverter model VZA

Figure

Dimensions in mm

W1

H1

W

H

D

t1

H2

D1

H3

H4

Weight

kg

Single-phase
200 V

0.12

B0P1

1

56

118

68

128

76

3

5

6.5

-

-

0.6

0.25

B0P2

0.7

0.55

B0P4

108

5

38.5

1.0

1.1

B0P7

2

96

108

137.5

58

1.7

1.5

B1P5

154

1.8

2.2

B2P2

128

140

163

65

2.4

4.0

B4P0

158

170

180

3.0

Three-phase
200 V

0.12

20P1

1

56

118

68

128

76

3

5

6.5

-

-

0.6

0.25

20P2

0.6

0.55

20P4

108

5

38.5

0.9

1.1

20P7

128

1.1

1.5

21P5

2

96

108

129

58

1.3

2.2

22P2

137.5

1.4

4.0

24P0

128

140

143

65

2.1

5.5

25P5

3

122

248

140

254

140

-

6

55

13

6.2

3.8

7.5

27P5

3.8

11

2011

160

284

180

290

163

8

75

15

5.5

15

2015

192

336

220

358

187

7

78

7.2

9.2

Three-phase
400 V

0.37

40P2

2

96

118

108

128

81

5

5

10

-

-

0.8

0.55

40P4

99

28

1.0

1.1

40P7

137.5

58

1.4

1.5

41P5

154

1.5

2.2

42P2

1.5

3.0

43P0

1.5

4.0

44P0

128

140

143

65

2.1

5.5

45P5

3

122

248

140

254

140

-

6

55

13

6

3.8

7.5

47P5

6.2

3.8

11

4011

160

284

180

290

143

8

15

6

5.2

15

4015

163

75

5.5

V1000 + Option board (Communication and 24 VDC power supply)

Built-in filter

VZA

Dimensions in mm

W

H

H1

D1

D2

D

B0P1

68+

178

50

69.5

6.5

76

B0P2

B0P4

79.5

38.5

118

B0P7

108

77.9

59.6

137.5

B1P5

89.4

64.6

154

B2P2

140

183

55

96.4

66.6

163

40P2

108

178

50

69.4

11.6

81

40P4

 

29.6

99

40P7

77.9

59.6

137.5

41P5

94.4

154

42P2

43P0

44P0

140

183

55

76.4

66.6

143

 


1. Only HD settings is available for this model

2. Based on a standard 4-pole motor for maximum applicable motor output:
Heavy Duty (HD) mode with a 150% overload capacity
Normal Duty (ND) mode with a 120% overload capacity

3. Based on a standard 4-pole motor for maximum applicable motor output:
Heavy Duty (HD) mode with a 150% overload capacity
Normal Duty (ND) mode with a 120% overload capacity

1. Only HD settings is available for this model

2. Based on a standard 4-pole motor for maximum applicable motor output:
Heavy Duty (HD) mode with a 150% overload capacity
Normal Duty (ND) mode with a 120% overload capacity

3. Based on a standard 4-pole motor for maximum applicable motor output:
Heavy Duty (HD) mode with a 150% overload capacity
Normal Duty (ND) mode with a 120% overload capacity

Software

CX-Drive

cx-drive2 prod
Reduce the time and complexity of configuring, commissioning and maintaining servos and inverters with a single software tool. CX-Drive includes support for features in the new Accurax G5 servo system and MX2 inverter.

CX-One

cx-one screen prod
CX-One software allows users to build, configure and program a host of devices such as PLCs, HMIs and motion-control systems and networks using just one software package with one installation and license number. This greatly reduces the complexity of the configuration and allows automation systems to be programmed or configured with minimal training.
Downloads

Brochures

Show all brochures

Device description files

Show all device description files

Datasheets

Show all datasheets

Manuals

Show all manuals

Have a question?

We are ready to help.

Contact us

Subscribe to product updates

Newsletters about product innovations, solutions and services, directly in your inbox.

Thank you for subscribing to Omron's eNews. You will shortly receive an e-mail from us. This e-mail contains a link which activates your email newsletter subscription. This method is used due to legal issues and to make certain that no-one can abuse your e-mail address.

We are experiencing technical difficulties. Your form submission has not been successful. Please accept our apologies and try again later. Details: [details]

Download

Product documentation

Download datasheets, manuals and brochures.

Browse download center

Training courses

Get the training from our best engineers. Beginner to advanced level.

View training courses