V1000
More performance & Quality in less space
This product is in the process of being discontinued.
- Current vector control
- High starting torque (200% / 0.5 Hz)
- 1:100 speed control range
- Double rating ND 120%/1min and HD 150%/1 min
- IM&PM motor control
- Online Tuning
- Low-noise Low carrier technology
- 10 years lifetime design
- Built-in filter
- Screw-less terminals
- Control Terminals with memory backup
- Fieldbus communications: Modbus, Profibus, CANopen, DeviceNet, LONworks, CompoNet, Ethernet, ML-II, PROFINET and EtherCAT
- Safety embedded: EN954-1 safety cat. 3, EN6158 SIL II and EN60204-1 Stop category 0
- CE, UL, cUL and TUV
Specifications & ordering info
Ordering information
V1000
Specifications | Order code | |||||
---|---|---|---|---|---|---|
Heavy Duty | Normal Duty | Standard | Built-in filter | |||
1x200 V | 0.12 kW | 0.8 A | 0.18 kW | 0.8 A | VZAB0P1BAA | VZAB0P1EAB |
0.25 kW | 1.6 A | 0.37 kW | 1.6 A | VZAB0P2BAA | VZAB0P2EAB | |
0.55 kW | 3.0 A | 0.75 kW | 3.5 A | VZAB0P4BAA | VZAB0P4EAB | |
1.1 kW | 5.0 A | 1.1 kW | 6.0 A | VZAB0P7BAA | VZAB0P7EAB | |
1.5 kW | 8.0 A | 2.2 kW | 9.6 A | VZAB1P5BAA | VZAB1P5EAB | |
2.2 kW | 11.0 A | 3.0 kW | 12.0 A | VZAB2P2BAA | VZAB2P2EAB | |
4.0 kW | 17.5 A | 5.5 kW | 21.0 A | VZAB4P0BAA | – | |
3x200 V | 0.12 kW | 0.8 A | 0.18 kW | 0.8 A | VZA20P1BAA | – |
0.25 kW | 1.6 A | 0.37 kW | 1.6 A | VZA20P2BAA | – | |
0.55 kW | 3.0 A | 0.75 kW | 3.5 A | VZA20P4BAA | – | |
1.1 kW | 5.0 A | 1.1 kW | 6.0 A | VZA20P7BAA | – | |
1.5 kW | 8.0 A | 2.2 kW | 9.6 A | VZA21P5BAA | – | |
2.2 kW | 11.0 A | 3.0 kW | 12.0 A | VZA22P2BAA | – | |
4.0 kW | 17.5 A | 5.5 kW | 21.0 A | VZA24P0BAA | – | |
5.5 kW | 25.0 A | 7.5 kW | 30.0 A | VZA25P5FAA | – | |
7.5 kW | 33.0 A | 11.0 kW | 40.0 A | VZA27P5FAA | – | |
11 kW | 47.0 A | 15.0 kW | 56.0 A | VZA2011FAA | – | |
15 kW | 60.0 A | 18.5 kW | 69.0 A | VZA2015FAA | – | |
3x400 V | 0.37 kW | 1.2 A | 0.37 kW | 1.2 A | VZA40P2BAA | VZA40P2EAB |
0.55 kW | 1.8 A | 0.75 kW | 2.1 A | VZA40P4BAA | VZA40P4EAB | |
1.1 kW | 3.4 A | 1.5 kW | 4.1 A | VZA40P7BAA | VZA40P7EAB | |
1.5 kW | 4.8 A | 2.2 kW | 5.4 A | VZA41P5BAA | VZA41P5EAB | |
2.2 kW | 5.5 A | 3.0 kW | 6.9 A | VZA42P2BAA | VZA42P2EAB | |
3.0 kW | 7.2 A | 4.0 kW | 8.8 A | VZA43P0BAA | VZA43P0EAB | |
4.0 kW | 9.2 A | 5.5 kW | 11.1 A | VZA44P0BAA | VZA44P0EAB | |
5.5 kW | 14.8 A | 7.5 kW | 17.5 A | VZA45P5FAA | – | |
7.5 kW | 18.0 A | 11.0 kW | 23.0 A | VZA47P5FAA | – | |
11 kW | 24.0 A | 15.0 kW | 31.0 A | VZA4011FAA | – | |
15 kW | 31.0 A | 18.5 kW | 38.0 A | VZA4015FAA | – |
① Line filters
Inverter | Standard line filter | Low leakage line filter | |||||||
---|---|---|---|---|---|---|---|---|---|
Schaffner | Rasmi | Schaffner | Rasmi | ||||||
Voltage | Model VZA |
Reference A1000-FIV |
Current (A) | Reference A1000-FIV |
Current (A) | Reference A1000-FIV |
Current (A) | Reference A1000-FIV |
Current (A) |
1-Phase 200 VAC |
B0P1 / B0P2 / B0P4 | 1010-SE | 10 | 1010-RE | 10 | 1010-SE-LL | 10 | 1010-RE-LL | 10 |
B0P7 / B1P5 | 1020-SE | 20 | 1020-RE | 20 | 1020-SE-LL | 20 | 1020-RE-LL | 20 | |
B2P2 | 1030-SE | 30 | 1030-RE | 30 | 1030-SE-LL | 24 | 1030-RE-LL | 30 | |
B4P0 | 1040-SE | 40 | 1040-RE | 40 | 1040-SE-LL | 40 | 1040-RE-LL | 40 | |
3-Phase 200 VAC |
20P1 / 20P2 / 20P4 / 20P7 | 2010-SE-V1 | 10 | 2010-RE | 10 | 2010-SE-LL | 10 | 2010-RE-LL | 10 |
21P5 / 22P2 | 2020-SE | 14 | 2020-RE | 16 | 2020-SE-LL | 20 | 2020-RE-LL | 16 | |
24P0 | 2030-SE | 24 | 2030-RE | 26 | 2030-SE-LL | 30 | 2030-RE-LL | 26 | |
25P5 / 27P5 | 2060-SE-V1 | 52 | 2060-RE | 60 | – | – | 2060-RE-LL | 60 | |
2011 | 2080-SE-V1 | 68 | 2080-RE | 80 | – | – | 2080-RE-LL | 80 | |
2015 | 2100-SE-V1 | 80 | 2100-RE | 100 | – | – | 2100-RE-LL | 100 | |
3-Phase 400 VAC |
40P2 / 40P4 | 3005-SE | 5 | 3005-RE | 5 | 3005-SE-LL | 5 | 3005-RE-LL | 5 |
40P7 / 41P5 / 42P2 / 43P0 | 3010-SE | 10 | 3010-RE | 10 | 3010-SE-LL | 10 | 3010-RE-LL | 10 | |
44P0 | 3020-SE | 15 | 3020-RE | 15 | 3020-SE-LL | 15 | 3020-RE-LL | 15 | |
45P5 / 47P5 | 3030-SE-V1 | 30 | 3030-RE | 30 | 3030-SE-LL | 30 | 3030-RE-LL | 30 | |
4011 / 4015 | 3050-SE-V2 | 50 | 3050-RE | 50 | 3050-SE-LL | 50 | 3050-RE-LL | 50 |
① Input AC reactors
Inverter | AC Reactor | |
---|---|---|
Voltage | Model VZA⬜ | Reference |
1-Phase 200 VAC | B0P1 / B0P2 / B0P4 | AX-RAI02000070-DE |
B0P7 | AX-RAI01700140-DE | |
B1P5 | AX-RAI01200200-DE | |
B2P2 | AX-RAI00630240-DE | |
B4P0 | – | |
3-Phase 200 VAC | 20P1 / 20P2 / 20P4 / 20P7 | AX-RAI02800080-DE |
21P5 / 22P2 / 24P0 | AX-RAI00880200-DE | |
25P5 / 27P5 | AX-RAI00350335-DE | |
2011 / 2015 | AX-RAI00180670-DE | |
3-Phase 400 VAC | 40P2 / 40P4 / 40P7 / 41P5 | AX-RAI07700050-DE |
42P2 / 43P0 / 44P0 | AX-RAI03500100-DE | |
45P5 / 47P5 | AX-RAI01300170-DE | |
4011 / 4015 | AX-RAI00740335-DE |
① DC reactors
200 V 1-phase | 200 V 3-phase | 400 V 3-phase | |||
---|---|---|---|---|---|
Model VZA⬜ | DC Reactor | Model VZA⬜ | DC Reactor | Model VZA⬜ | DC Reactor |
B0P1 | AX-RC10700032-DE | 20P1 | AX-RC21400016-DE | 40P2 / 40P4 | AX-RC43000020-DE |
B0P2 | 20P2 | 40P7 | AX-RC27000030-DE | ||
B0P4 | AX-RC06750061-DE | 20P4 | AX-RC10700032-DE | 41P5 | AX-RC14000047-DE |
B0P7 | AX-RC03510093-DE | 20P7 | AX-RC06750061-DE | 42P2 | AX-RC10100069-DE |
B1P5 | AX-RC02510138-DE | 21P5 | AX-RC03510093-DE | 43P0 / 44P0 | AX-RC06400116-DE |
B2P2 | AX-RC01600223-DE | 22P2 | AX-RC02510138-DE | 45P5 | AX-RC04410167-DE |
B4P0 | – | 24P0 | AX-RC01600223-DE | 47P5 | AX-RC03350219-DE |
– | 25P5 | AX-RC01110309-DE | 4011 | AX-RC02330307-DE | |
27P5 | AX-RC00840437-DE | 4015 | AX-RC01750430-DE | ||
2011 | AX-RC00590614-DE | – | |||
2015 | AX-RC00440859-DE |
① Chokes
Model | Diameter | Description |
---|---|---|
AX-FER2102-RE | 21 | For 2.2 KW motors or below |
AX-FER2515-RE | 25 | For 15 KW motors or below |
AX-FER5045-RE | 50 | For 45 KW motors or below |
① Output AC reactor
Inverter | AC Reactor | |
---|---|---|
Voltage | Model VZA⬜ | Reference |
200 VAC | B0P1 / B0P2 / B0P4 20P1 / 20P2 / 20P4 |
AX-RAO11500026-DE |
B0P7 / 20P7 | AX-RAO07600042-DE | |
B1P5 / 21P5 | AX-RAO04100075-DE | |
B2P2 / 22P2 | AX-RAO03000105-DE | |
B4P0 / 24P0 | AX-RAO01830160-DE | |
25P5 | AX-RAO01150220-DE | |
27P5 | AX-RAO00950320-DE | |
2011 | AX-RAO00630430-DE | |
2015 | AX-RAO00490640-DE | |
400 VAC | 40P2 / 40P4 / 40P7 / 41P5 | AX-RAO16300038-DE |
42P2 | AX-RAO11800053-DE | |
43P0 / 44P0 | AX-RAO07300080-DE | |
45P5 | AX-RAO04600110-DE | |
47P5 | AX-RAO03600160-DE | |
4011 | AX-RAO02500220-DE | |
4015 | AX-RAO02000320-DE |
② Communication cards
Type | Description | Function | Order code |
---|---|---|---|
Communication option board | DeviceNet option card | Used for running or stopping the inverter, setting or referencing parameters, and monitoring output frequency, output current, or similar items through DeviceNet communication with the host controller. |
SI-N3/V |
PROFIBUS-DP option card | Used for running or stopping the inverter, setting or referencing parameters, and monitoring output frequency, output current, or similar items through PROFIBUS-DP communication with the host controller. |
SI-P3/V | |
CANopen option card | Used for running or stopping the inverter, setting or referencing parameters, and monitoring output frequency, output current, or similar items through CANopen communication with the host controller. |
SI-S3/V | |
MECHATROLINK-II option card | Used for running or stopping the inverter, setting or referencing parameters, and monitoring output frequency, output current, or similar items through MECHATROLINK-II communication with the host controller. |
SI-T3/V | |
EtherCAT option card | Used for running or stopping the inverter, setting or referencing parameters, and monitoring output frequency, output current, or similar items through EtherCAT communication with the host controller. |
EUOP-SI-ES3/V | |
PROFINET option card | Used for running or stopping the inverter, setting or referencing parameters, and monitoring output frequency, output current, or similar items through PROFINET communication with the host controller. |
SI-EP3/V |
③ Accessories
Types | Description | Functions | Order code |
---|---|---|---|
Digital operator | LCD remote operator | LCD Display operator with language support | JVOP-180 |
Remote operator cable | 3 meters cable for connecting remote operator | A1000-CAVOP300-EE | |
Accessories | USB converter / USB cable | USB converter unit with copy and backup function | JVOP-181 |
24 VDC option board | 24VDC control board power supply VZA-B/2/4 from 0.1 to 4 KW | PS-V10S | |
24VDC control board power supply VZA-2/4 from 5.5 to 15 KW | PS-V10M | ||
PC connection cable | RS232 PC tool connection cable | A1000-CAVPC232-EE |
④ Computer software
Types | Description | Installation | Order code |
---|---|---|---|
Software | Computer software | Configuration and monitoring software tool | CX-Drive |
Computer software | Configuration and monitoring software tool | CX-One |
⑤ Braking unit, braking resistor unit
Inverter | Braking resistor unit | ||||||
---|---|---|---|---|---|---|---|
Voltage | Max. motor kW |
Inverter model VZA⬜ | Connectable min. resistance W |
Inverter mounted type (3 %ED, 10 sec max) | Braking torque % |
||
1-phase | 3-phase | Type AX- | Resist Ω | ||||
200 V (single-/three-phase) |
0.12 | B0P1 | 20P1 | 300 | REM00K1400-IE | 400 | 135 |
0.25 | B0P2 | 20P2 | 120 | ||||
0.55 | B0P4 | 20P4 | 200 | REM00K1200-IE | 200 | 120 | |
1.1 | B0P7 | 20P7 | 120 | 70 | |||
1.5 | B1P5 | 21P5 | 60 | REM00K2070-IE | 70 | 190 | |
2.2 | B2P2 | 22P2 | 120 | ||||
4.0 | B4P0 | 24P0 | 32 | REM00K4035-IE | 35 | 135 | |
5.5 | – | 25P5 | 16 | 75 | |||
7.5 | – | 27P5 | 9.6 | 55 | |||
11 | – | 2011 | REM00K6035-IE | 35 | 40 | ||
15 | – | 2015 | REM00K9017-IE | 17 | 55 | ||
400 V (three-phase) |
0.37 | – | 40P2 | 750 | 2 x REM00K1400-IE | 800 | 270 |
0.55 | – | 40P4 | 270 | ||||
1.1 | – | 40P7 | 510 | 270 | |||
1.5 | – | 41P5 | 240 | REM00K1400-IE | 400 | 130 | |
2.2 | – | 42P2 | 200 | REM00K2200-IE | 200 | 130 | |
3.0 | – | 43P0 | 100 | REM00K2120-IE | 120 | 215 | |
4.0 | – | 44P0 | 160 | ||||
5.5 | – | 45P5 | 32 | REM00K4035-IE | 35 | 140 | |
7.5 | – | 47P5 | 80 | ||||
11 | – | 4011 | 20 | REM00K6035-IE | 35 | 50 | |
15 | – | 4015 | REM00K9020-IE | 20 | 55 |
⑥ Mounting accessories
Types | Description | Applicable models VZA⬜ | Order code |
---|---|---|---|
DIN Rail | Necessary to mount the inverter on a DIN rail | B0P1/B0P2/B0P4 20P1/20P2/20P4/20P7 |
EZZ08122A |
B0P7/B1P5 21P5/22P2 40P2/40P4/40P7/41P5/42P2 |
EZZ08122B | ||
B2P2 24P0 44P0 |
EZZ08122C | ||
B4P0 | EZZ08122D | ||
Heatsink external mounting attachment |
Additional items to mount the inverter with the heatsink out of the panel |
B0P1/B0P2 20P1/20P2 |
100-034-075 |
B0P4 20P4 |
100-034-076 | ||
20P7 | 100-034-077 | ||
40P2 | 100-034-078 | ||
B1P5 21P5/22P2 41P5/42P2/43P0 |
100-034-079 | ||
B2P2 24P0 44P0 |
100-034-080 | ||
B4P0 | 100-036-357 | ||
B0P7 40P2/40P4 |
100-036-418 | ||
25P5/27P5 45P5/47P5 |
100-036-300 | ||
2011 4011/4015 |
100-036-301 | ||
2015 | 100-036-302 |
Specifications
200 V class
Single-phase: VZA⬜ | B0P1 | B0P2 | B0P4 | B0P7 | B1P5 | B2P2 | B4P0
2
Only HD settings is available for this
model |
– | – | – | – | |
---|---|---|---|---|---|---|---|---|---|---|---|---|
Three-phase: VZA⬜ | 20P1 | 20P2 | 20P4 | 20P7 | 21P5 | 22P2 | 24P0 | 25P5 | 27P5 | 2011 | 2015 | |
Motor kW
2
Based on a standard 4-pole motor for maximum applicable motor output: Heavy Duty (HD) mode with a 150% overload capacity Normal Duty (ND) mode with a 120% overload capacity |
For HD setting | 0.12 | 0.25 | 0.4 | 1.1 | 1.5 | 2.2 | 4.0 | 5.5 | 7.5 | 11 | 15 |
For ND setting | 0.18 | 0.37 | 0.55 | 1.1 | 2.2 | 3.0 | 5.51 | 7.5 | 11 | 15 | 18.5 | |
Output characteristics |
Inverter capacity kVA | 0.3 | 0.6 | 1.1 | 1.9 | 3.0 | 4.2 | 6.7 | 9.5 | 13 | 18 | 23 |
Rated output current (A) at HD | 0.8 | 1.6 | 3.0 | 5.0 | 8.0 | 11.0 | 17.5 | 25.0 | 33.0 | 47.0 | 60.0 | |
Rated output current (A) at ND | 1.2 | 1.9 | 3.5 | 6.0 | 9.6 | 12.0 | 19.6 | 30.0 | 40.0 | 56.0 | 69.0 | |
Max. output voltage | Proportional to input voltage: 0..240 V | |||||||||||
Max. output frequency | 400 Hz | |||||||||||
Power supply |
Rated input voltage and frequency |
Single-phase 200..240 V 50/60 Hz 3-phase 200..240 V 50/60 Hz |
||||||||||
Allowable voltage fluctuation |
–15%..+10% | |||||||||||
Allowable frequency fluctuation |
+5% |
400 V class
Three-phase: VZA⬜ | 40P2 | 40P4 | 40P7 | 41P5 | 42P2 | 43P0 | 44P0 | 45P5 | 47P5 | 4011 | 4015 | |
---|---|---|---|---|---|---|---|---|---|---|---|---|
Motor kW
2
Based on a standard 4-pole motor for maximum applicable motor output: Heavy Duty (HD) mode with a 150% overload capacity Normal Duty (ND) mode with a 120% overload capacity |
For HD setting | 0.37 | 0.55 | 1.10 | 1.5 | 2.2 | 3.0 | 4.0 | 5.5 | 7.5 | 11 | 15 |
For ND setting | 0.37 | 0.75 | 1.5 | 2.2 | 3.0 | 4.0 | 5.5 | 7.5 | 11 | 15 | 18.5 | |
Output characteristics |
Inverter capacity kVA | 0.9 | 1.4 | 2.6 | 3.7 | 4.2 | 5.5 | 7.2 | 9.2 | 14.8 | 18 | 24 |
Rated output current (A) at HD | 1.2 | 1.8 | 3.4 | 4.8 | 5.5 | 7.2 | 9.2 | 14.8 | 18.0 | 24 | 31 | |
Rated output current (A) at ND | 1.2 | 2.1 | 4.1 | 5.4 | 6.9 | 8.8 | 11.1 | 17.5 | 23 | 31 | 38 | |
Max. output voltage | 0..480 V (proportional to input voltage) | |||||||||||
Max. output frequency | 400 Hz | |||||||||||
Power supply |
Rated input voltage and frequency |
3-phase 380..480 VAC, 50/60 Hz | ||||||||||
Allowable voltage fluctuation |
–15%..+10% | |||||||||||
Allowable frequency fluctuation |
+5% |
Dimensions
IP20 type
Voltage class | Max. applicable motor output kW |
Inverter model VZA⬜ |
Figure | Dimensions in mm | ||||||||||
---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
W1 | H1 | W | H | D | t1 | H2 | D1 | H3 | H4 | Weight kg |
||||
Single-phase 200 V |
0.12 | B0P1 | 1 | 56 | 118 | 68 | 128 | 76 | 3 | 5 | 6.5 | – | – | 0.6 |
0.25 | B0P2 | 0.7 | ||||||||||||
0.55 | B0P4 | 108 | 5 | 38.5 | 1.0 | |||||||||
1.1 | B0P7 | 2 | 96 | 108 | 137.5 | 58 | 1.7 | |||||||
1.5 | B1P5 | 154 | 1.8 | |||||||||||
2.2 | B2P2 | 128 | 140 | 163 | 65 | 2.4 | ||||||||
4.0 | B4P0 | 158 | 170 | 180 | 3.0 | |||||||||
Three-phase 200 V |
0.12 | 20P1 | 1 | 56 | 118 | 68 | 128 | 76 | 3 | 5 | 6.5 | – | – | 0.6 |
0.25 | 20P2 | 0.6 | ||||||||||||
0.55 | 20P4 | 108 | 5 | 38.5 | 0.9 | |||||||||
1.1 | 20P7 | 128 | 1.1 | |||||||||||
1.5 | 21P5 | 2 | 96 | 108 | 129 | 58 | 1.3 | |||||||
2.2 | 22P2 | 137.5 | 1.4 | |||||||||||
4.0 | 24P0 | 128 | 140 | 143 | 65 | 2.1 | ||||||||
5.5 | 25P5 | 3 | 122 | 248 | 140 | 254 | 140 | – | 6 | 55 | 13 | 6.2 | 3.8 | |
7.5 | 27P5 | 3.8 | ||||||||||||
11 | 2011 | 160 | 284 | 180 | 290 | 163 | 8 | 75 | 15 | 5.5 | ||||
15 | 2015 | 192 | 336 | 220 | 358 | 187 | 7 | 78 | 7.2 | 9.2 | ||||
Three-phase 400 V |
0.37 | 40P2 | 2 | 96 | 118 | 108 | 128 | 81 | 5 | 5 | 10 | – | – | 0.8 |
0.55 | 40P4 | 99 | 28 | 1.0 | ||||||||||
1.1 | 40P7 | 137.5 | 58 | 1.4 | ||||||||||
1.5 | 41P5 | 154 | 1.5 | |||||||||||
2.2 | 42P2 | 1.5 | ||||||||||||
3.0 | 43P0 | 1.5 | ||||||||||||
4.0 | 44P0 | 128 | 140 | 143 | 65 | 2.1 | ||||||||
5.5 | 45P5 | 3 | 122 | 248 | 140 | 254 | 140 | – | 6 | 55 | 13 | 6 | 3.8 | |
7.5 | 47P5 | 6.2 | 3.8 | |||||||||||
11 | 4011 | 160 | 284 | 180 | 290 | 143 | 8 | 15 | 6 | 5.2 | ||||
15 | 4015 | 163 | 75 | 5.5 |
V1000 + Option board (Communication and 24 VDC power supply)
Built-in filter
VZA⬜ | Dimensions in mm | |||||
---|---|---|---|---|---|---|
W | H | H1 | D1 | D2 | D | |
B0P1 | 68+ | 178 | 50 | 69.5 | 6.5 | 76 |
B0P2 | ||||||
B0P4 | 79.5 | 38.5 | 118 | |||
B0P7 | 108 | 77.9 | 59.6 | 137.5 | ||
B1P5 | 89.4 | 64.6 | 154 | |||
B2P2 | 140 | 183 | 55 | 96.4 | 66.6 | 163 |
40P2 | 108 | 178 | 50 | 69.4 | 11.6 | 81 |
40P4 | 29.6 | 99 | ||||
40P7 | 77.9 | 59.6 | 137.5 | |||
41P5 | 94.4 | 154 | ||||
42P2 | ||||||
43P0 | ||||||
44P0 | 140 | 183 | 55 | 76.4 | 66.6 | 143 |
Ordering information
V1000
① Line filters
① Input AC reactors
① DC reactors
① Chokes
① Output AC reactor
② Communication cards
③ Accessories
④ Computer software
⑤ Braking unit, braking resistor unit
⑥ Mounting accessories
Additional items to mount the inverter with the heatsink out of the panel |
|||
Specifications
200 V class
B4P01 |
||||||||||||
---|---|---|---|---|---|---|---|---|---|---|---|---|
Motor kW2 |
||||||||||||
400 V class
Motor kW3 |
||||||||||||
Dimensions
IP20 type
V1000 + Option board (Communication and 24 VDC power supply)
Built-in filter
How can we help you?
If you have a question or would like to ask for a quote, please contact us or send a request.
Contact me V1000
Thank you for submitting your request. We will come back to you as soon as possible.
We are experiencing technical difficulties. Your form submission has not been successful. Please accept our apologies and try again later. Details: [details]
DownloadQuotation for V1000
By completing this form you can request a quotation. Your personal details will be handled confidentially.
Thank you for requesting a quotation. We will provide you with the required information as soon as possible.
We are experiencing technical difficulties. Your form submission has not been successful. Please accept our apologies and try again later. Details: [details]
DownloadFeatures
Ratings
- 200 V Class single-phase 0.1 to 4 kW
- 200 V Class three-phase 0.1 to 15 kW
- 400 V Class three-phase 0.2 to 15 kW
Related products
-
One software tool for inverters & servos
-
One software for your automation system
-
Driving quality - Q2V Compact Drive