Login

Please use more than 6 characters. Forgot your password? Click here to reset.

Change password

We are experiencing technical difficulties. Your form submission has not been successful. Please accept our apologies and try again later. Details: [details]

Download

Register

Text error notification

Text error notification

Checkbox error notification

Checkbox error notification

We are experiencing technical difficulties. Your form submission has not been successful. Please accept our apologies and try again later. Details: [details]

Download

Thank you for registering

An email to complete your account has been sent to

Return to the website

get direct access

Fill in your details below and get direct access to view content

Text error notification

Text error notification

Checkbox error notification

Checkbox error notification

We are experiencing technical difficulties. Your form submission has not been successful. Please accept our apologies and try again later. Details: [details]

Download

Thank you for your interest

You now have access to S8JX-P

A confirmation email has been sent to

Continue to page

Please or get direct access to download this document

S8JX-P

Features

EMI Class B and Power Factor Correction

The main improvements provided by the S8JX-P models are harmonic current suppression/PFC (Power Factor Correction) and EMI EN55011 Class B compliance. In addition, further functions have been implemented (applies only to 300 and 600 W models):

  • Remote Sensing, to compensate for voltage drops on the load lines.
  • Remote Control, using an external signal allows you to turn the output ON and OFF without removing the input voltage.
  • Alarm output, informing you about power supply errors, such as fan failure or insufficient voltage
Additional units

S8T-DCBU-02

s8t-dcbu-02 2 prod
Prevents equipment stoppage, data loss and other problems resulting from momentary power failures. One S8T-DCBU-02 buffer block provides a back-up time of 500 ms at an output current of 2.5 A. Can be wired to the 24 VDC output from any switch mode power supply.

S8M

s8m prod
The S8M turns your machine directly into UL Class 2 compliant, maximum tripping current is 3,8A per channel (adjustable). This unit controls up to 4 circuits. On top of this you will get startup / shutdown –sequence control, display and alarm functions, like voltage, output current, runtime, and over temperature and external reset. These functions can be set by using the front buttons or with the free support tool software. These settings can be protected.

S8VK-R

s8vk-r20 prod
When the S8VK-R is used with switching power supplies, it provides a backup system for critical applications that require absolute reliability and zero downtime.
Specifications & ordering info

Ordering information

Power ratings

Output voltage

Output current

Size in mm (H × W × D)

Order code

50 W

24 V

2.1 A

92 × 42 × 129

S8JX-P05024CD

100 W

24 V

4.5 A

92 × 42 × 159

S8JX-P10024CD

150 W

12 V

13 A

92 × 42 × 159

S8JX-P15012CD

24 V

6.5 A

S8JX-P15024CD

300 W

12 V

27 A

92 × 71 × 165

S8JX-P30012CD

24 V

14 A

S8JX-P30024CD

600 W

12 V

53 A

92 × 110 × 165

S8JX-P60012CD

24 V

27 A

S8JX-P60024CD

Note: There are other models available on request: 50 W and 100 W (5 VDC, 12 VDC, 48 VDC); 150 W, 300 W and 600 W (5 VDC, 48 VDC).
Please contact your Omron representative for special request.

Specifications

Item

50 W

100 W

150 W

300 W

600 W

Efficiency (Typ. at 230 VAC)

82% (24 V)

87% (24 V)

88% (24 V)

87% (24 V)

85% (24 V)

Input

Rated input voltage

100 to 240 VAC

Allowable range

85 to 264 VAC, 80 to 370 VDC (DC is not applicable for the safety standards.)

Output

Voltage adjustment range (with V.ADJ)

−10% to 15% for 5 V to 24 V,
±10% for 48 V (with V.ADJ)

−10% to 15% for 12 V and 24 V,
±10% for 5 V and 48 V

Input variation influence

0.4% max. (at 85 to 264 VAC input, 100% load)

Load variation Influence

0.8% max. at 0% to 100% load

Temperature variation influence

0.05%/°C max.

Overload protection

Yes, 105% to 160% of rated current

Power Boost

115% of rated current for 24 V only

Overvoltage protection

Yes

Operating ambient temperature

−10 to 70°C (14 to 158°F)

Series operation

Yes, up to 2 units

Parallel operation

No

Yes, up to 5 units

EMI

Conforms to EN 61204-3, EN 55011 Class B

EMS

Conforms to EN 61204-3 high severity levels

Harmonic current emissions

Conforms to EN61000-3-2

Approved standards

UL: UL508 (Listing), UL60950-1, cUL: CSA C22.2 No. 107.1 and No. 60950-1,
EN/VDE: EN 50178 (=VDE0160), EN 60950-1 (=VDE0805),

Fulfilled standards

EN 50274 for Terminal parts

Have a question?

We are ready to help.

Contact us

Subscribe to product updates

Newsletters about product innovations, solutions and services, directly in your inbox.

Thank you for subscribing to Omron's eNews. You will shortly receive an e-mail from us. This e-mail contains a link which activates your email newsletter subscription. This method is used due to legal issues and to make certain that no-one can abuse your e-mail address.

We are experiencing technical difficulties. Your form submission has not been successful. Please accept our apologies and try again later. Details: [details]

Download

Product documentation

Download datasheets, manuals and brochures.

Browse download center

Training courses

Get the training from our best engineers. Beginner to advanced level.

View training courses