NX1
Information & Productivity in a miniaturized size controller
The NX1 series modular machine controller provides logic sequence, motion and information functionality. NX1 is joining production and IT worlds, minimizing engineering and maintenance while suppressing middleware.
- IoT Ready: OPC UA server built-in as standard feature, variable structures are supported
- Database direct connection: SQL client for server Microsoft SQL, Oracle, IBM DB2, MySQL, Firebird, PostgreSQL
- Large memory for data handling. 33.5 MB for variables
- Battery-less controller
- Cycle time: from 1 ms
- Up to 12 axes (8 synchronized motion axes & 4 PTP)
- One unique and synchronized cycle for local & remote I/O, EtherCAT devices and motion control
- Database direct connection in V2.0 is expanded with stored procedure calls and secure communications functionality
- Database direct connection: SQL client for server Microsoft SQL, Oracle, IBM DB2, MySQL, Firebird, PostgreSQL
- Multi-tasking controller
- Expanded network connectivity, 2x Ethernet ports + 1 EtherCAT
- Up to 32 local NX units, including Safety and IO-Link master
- Support up to 64 EtherCAT nodes (400xNX units)
- EtherCAT Ring topology is supported to maintain communications and control in case of a broken cable or device failure
Specifications & ordering info
Ordering information
NX1 series CPU units
CPU | Program capacity | Variables capacity | Number of axes | Functionalities | Order code | |||||
---|---|---|---|---|---|---|---|---|---|---|
Real axes | Motion control servo axes | Single-axis position control axes | Sequence | OPC UA | Motion | DB connection | ||||
NX102 | 5 MB |
1.5 MB: Retained 32 MB: Not retained |
12 axes | 8 axes | 4 axes | NX102-1220 | ||||
– |
NX102-1200 | |||||||||
8 axes | 4 axes | NX102-1120 | ||||||||
– | NX102-1100 | |||||||||
6 axes | 2 axes | NX102-1020 | ||||||||
– | NX102-1000 | |||||||||
4 axes | 0 axes | – | NX102-9020 | |||||||
– | – | NX102-9000 |
The end cover unit NX-END02 is included with the CPU unit.
NX I/O units (local and remote I/O)
Up to 32 local NX I/O units can be connected to an NX1 CPU unit.
Communication and control units
Module Type | Protocol | Connection | Specification | Width | Order code |
---|---|---|---|---|---|
Communication coupler | EtherCAT Slave |
2 RJ45 ports (in + out) |
Up to 63 I/O units. Max. 1,024 bytes in + 1,024 bytes out Supports distributed clock I/O power supply up to 10 A |
46 mm | NX-ECC203 |
Safety controller | FSoE Protocol | 128 Safety connections | For up to 1,024 safety I/O points | 30 mm | NX-SL3500 |
32 Safety connections | For up to 256 safety I/O points | NX-SL3300 |
IO-Link master unit
Module Type | No. of ports | I/O refresh method | Connection type
2
Units with screwless push-in
connections are supplied with the appropriate terminal connector.
Units with MIL/Fujitsu connectors are supplied without matching
plugs. |
Width | Order code |
---|---|---|---|---|---|
IO-Link master unit | 4 | Free Run | Screwless push-in (NX-TBA162) | 12 mm | NX-ILM400 |
For more detailed information about IO-Link master unit, refer to “IO-Link master datasheet (I191E-EN)”.
Digital I/O units
Module type | Channels, Signal type | Performance
2 ,
I/O Refresh ModeDigital I/O performance
|
Connection type
2
Units with screwless push-in
connections are supplied with the appropriate terminal connector.
Units with MIL/Fujitsu connectors are supplied without matching
plugs. |
Width | Order code | NPN-type
2
Order codes are for PNP-type signals
(positive switching, 0 V common). Most models are also available
as NPN-type (negative switching, 24 V common). Inputs of MIL-connector
versions can be used as NPN or PNP. |
||||||||||||||||||||||||||||||||||||
---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
AC Digital Input | 4 inputs, 200 to 240 VAC, 50/60 Hz | Free Run | Screwless push-in (NX-TBA082) | 12 mm | NX-IA3117 | – | ||||||||||||||||||||||||||||||||||||
Safety Digital Input | 4 inputs + 2 test outputs | Free Run | Screwless push-in (NX-TBA082) | 12 mm | NX-SIH400 | – | ||||||||||||||||||||||||||||||||||||
8 inputs + 2 test outputs | Screwless push-in (NX-TBA162) | NX-SID800 | – | |||||||||||||||||||||||||||||||||||||||
DC Digital Input | 4 inputs, 3-wire connection | High-speed Synchronous Time Stamp | Screwless push-in (NX-TBA122) | 12 mm | NX-ID3444 | NX-ID3344 | ||||||||||||||||||||||||||||||||||||
High-speed Synchronous/Free Run | NX-ID3443 | NX-ID3343 | ||||||||||||||||||||||||||||||||||||||||
Synchronous/Free Run | NX-ID3417 | NX-ID3317 | ||||||||||||||||||||||||||||||||||||||||
8 inputs, 2-wire connection | Screwless push-in (NX-TBA162) | NX-ID4442 | NX-ID4342 | |||||||||||||||||||||||||||||||||||||||
16 inputs, 1-wire connection | NX-ID5442 | NX-ID5342 | ||||||||||||||||||||||||||||||||||||||||
1 × 20-pin MIL connector | 30 mm | NX-ID5142-5 | same | |||||||||||||||||||||||||||||||||||||||
M3 screw | NX-ID5142-1 | same | ||||||||||||||||||||||||||||||||||||||||
32 inputs, 1-wire connection | 1 × 40-pin MIL connector | NX-ID6142-5 | same | |||||||||||||||||||||||||||||||||||||||
1 × 40-pin Fujitsu connector | NX-ID6142-6 | same | ||||||||||||||||||||||||||||||||||||||||
DC Digital I/O | 16 inputs + 16 outputs 0.5 A, 1-wire connection + common | Synchronous/Free Run | 2 × 20-pin MIL connector | 30 mm | NX-MD6256-5 | NX-MD6121-5 | ||||||||||||||||||||||||||||||||||||
2 × 24-pin Fujitsu connector | – | NX-MD6121-6 | ||||||||||||||||||||||||||||||||||||||||
DC Digital Output | 2 outputs 0.5 A, 3-wire connection | High-speed Synchronous Time Stamp | Screwless push-in (NX-TBA082) | 12 mm | NX-OD2258 | NX-OD2154 | ||||||||||||||||||||||||||||||||||||
4 outputs 0.5 A, 3-wire connection | High-speed Synchronous/Free Run | Screwless push-in (NX-TBA122) | NX-OD3257 | NX-OD3153 | ||||||||||||||||||||||||||||||||||||||
Synchronous/Free Run | NX-OD3256 | NX-OD3121 | ||||||||||||||||||||||||||||||||||||||||
4 outputs 2 A/point, 8 A total, 3-wire connection | Screwless push-in (NX-TBA162) | NX-OD3268 | – | |||||||||||||||||||||||||||||||||||||||
8 outputs 0.5 A, 2-wire connection | NX-OD4256 | NX-OD4121 | ||||||||||||||||||||||||||||||||||||||||
16 outputs 0.5 A, 1-wire connection | NX-OD5256 | NX-OD5121 | ||||||||||||||||||||||||||||||||||||||||
1 × 20-pin MIL connector | 30 mm | NX-OD5256-5 | NX-OD5121-5 | |||||||||||||||||||||||||||||||||||||||
M3 screw | NX-OD5256-1 | NX-OD5121-1 | ||||||||||||||||||||||||||||||||||||||||
32 outputs 0.5 A, 1-wire connection | 1 × 40-pin MIL connector | NX-OD6256-5 | NX-OD6121-5 | |||||||||||||||||||||||||||||||||||||||
1 × 40-pin Fujitsu connector | – | NX-OD6121-6 | ||||||||||||||||||||||||||||||||||||||||
Safety Digital Output | 2 outputs, 2.0 A | Free Run | Screwless push-in (NX-TBA082) | 12 mm | NX-SOH200 | – | ||||||||||||||||||||||||||||||||||||
4 outputs, 0.5 A | NX-SOD400 | – | ||||||||||||||||||||||||||||||||||||||||
Relay Digital Output | 2 outputs, N.O., 2.0 A | Free Run | Screwless push-in (NX-TBA082) | 12 mm | NX-OC2633 | – | ||||||||||||||||||||||||||||||||||||
8 outputs, N.O., 2.0 A | Screwless push-in (NX-TBA082 × 2) | 24 mm | NX-OC4633 | – | ||||||||||||||||||||||||||||||||||||||
2 outputs, N.O.+ N.C., 2.0 A | Screwless push-in (NX-TBA082) | 12 mm | NX-OC2733 | – |
Analog I/O units
Module type | Signal type | Performance, I/O Refresh Mode | Channels | Connection type
2
Units with screwless push-in
connections are supplied with the appropriate terminal connector.
Units with MIL/Fujitsu connectors are supplied without matching
plugs. |
Width | Order code |
---|---|---|---|---|---|---|
Temperature Sensor -Input | Thermocouple type B,E,J,K,L,N,R,S,T,U,WRe5-26,PLII |
0.1°C resolution, 200 ms/unit Free Run |
2 | Screwless push-in terminal block(s) with cold junction sensor, calibrated -individually at the factory | 12 mm | NX-TS2101 |
4 | 24 mm | NX-TS3101 | ||||
0.01°C resolution, 10 ms/unit Free Run |
2 | 12 mm | NX-TS2102 | |||
4 | 24 mm | NX-TS3102 | ||||
0.001°C resolution, 60 ms/unit Free Run |
2 | 12 mm | NX-TS2104 | |||
4 | 24 mm | NX-TS3104 | ||||
RTD type Pt100 (3-wire), Pt1000, Ni508.4 |
0.1°C resolution, 200 ms/unit Free Run |
2 | Screwless push-in (NX-TBA162) | 12 mm | NX-TS2201 | |
4 | Screwless push-in (NX-TBA162 + NX-TBB162) |
24 mm | NX-TS3201 | |||
0.01°C resolution, 10 ms/unit Free Run |
2 | Screwless push-in (NX-TBA162) | 12 mm | NX-TS2202 | ||
4 | Screwless push-in (NX-TBA162 + NX-TBB162) |
24 mm | NX-TS3202 | |||
0.001°C resolution, 60 ms/unit Free Run |
2 | Screwless push-in (NX-TBA162) | 12 mm | NX-TS2204 | ||
4 | Screwless push-in (NX-TBA162 + NX-TBB162) |
24 mm | NX-TS3204 | |||
Analog Input | 4 to 20 mA single ended |
1/8000 resolution, 250 µs/channel Free Run |
2 | Screwless push-in (NX-TBA082) | 12 mm | NX-AD2203 |
4 | Screwless push-in (NX-TBA122) | NX-AD3203 | ||||
8 | Screwless push-in (NX-TBA162) | NX-AD4203 | ||||
4 to 20 mA differential |
1/8000 resolution, 250 µs/channel Free Run |
2 | Screwless push-in (NX-TBA082) | NX-AD2204 | ||
4 | Screwless push-in (NX-TBA122) | NX-AD3204 | ||||
8 | Screwless push-in (NX-TBA162) | NX-AD4204 | ||||
1/30000 resolution,10 µs/channel Synchronous/Free Run |
2 | Screwless push-in (NX-TBA082) | NX-AD2208 | |||
4 | Screwless push-in (NX-TBA122) | NX-AD3208 | ||||
8 | Screwless push-in (NX-TBA162) | NX-AD4208 | ||||
–10 to 10 V single ended |
1/8000 resolution, 250 µs/channel Free Run |
2 | Screwless push-in (NX-TBA082) | NX-AD2603 | ||
4 | Screwless push-in (NX-TBA122) | NX-AD3603 | ||||
8 | Screwless push-in (NX-TBA162) | NX-AD4603 | ||||
–10 to 10 V differential |
1/8000 resolution, 250 µs/channel Free Run |
2 | Screwless push-in (NX-TBA082) | NX-AD2604 | ||
4 | Screwless push-in (NX-TBA122) | NX-AD3604 | ||||
8 | Screwless push-in (NX-TBA162) | NX-AD4604 | ||||
1/30000 resolution,10 µs/channel Synchronous/Free Run |
2 | Screwless push-in (NX-TBA082) | NX-AD2608 | |||
4 | Screwless push-in (NX-TBA122) | NX-AD3608 | ||||
8 | Screwless push-in (NX-TBA162) | NX-AD4608 | ||||
High-Speed Analog Input | –10 to 10 V, –5 to 5 V, 0 to 10 V, 0 to 5 V, 1 to 5 V, 0 to 20 mA, 4 to 20 mA differential |
–10 to 10 V or –5 to 5 V: 1/64000 Other input range: 1/32000 5 µs/channel Synchronous |
4 (NPN) | Screwless push-in (NX-TBA162 + NX-TBB162) |
24 mm | NX-HAD401 |
4 (PNP) | NX-HAD402 | |||||
Analog Output | 4 to 20 mA | 1/8000 resolution, 250 µs/channel Free Run |
2 | Screwless push-in (NX-TBA082) | 12 mm | NX-DA2203 |
4 | Screwless push-in (NX-TBA122) | NX-DA3203 | ||||
1/30000 resolution,10 µs/channel Synchronous/Free Run |
2 | Screwless push-in (NX-TBA082) | NX-DA2205 | |||
4 | Screwless push-in (NX-TBA122) | NX-DA3205 | ||||
–10 to 10 V | 1/8000 resolution, 250 µs/channel Free Run |
2 | Screwless push-in (NX-TBA082) | NX-DA2603 | ||
4 | Screwless push-in (NX-TBA122) | NX-DA3603 | ||||
1/30000 resolution,10 µs/channel Synchronous/Free Run |
2 | Screwless push-in (NX-TBA082) | NX-DA2605 | |||
4 | Screwless push-in (NX-TBA122) | NX-DA3605 |
Temperature control units
Module type | Conversion time, I/O Refresh Mode |
Channels | Input type | Output type | Output capacity | CT Input capacity | Control type | Connection type
2
Units with screwless push-in
connections are supplied with the appropriate terminal connector.
Units with MIL/Fujitsu connectors are supplied without matching
plugs. |
Width | Order code |
---|---|---|---|---|---|---|---|---|---|---|
Temperature control |
50 ms Free run |
2 | Multi-input (Thermocouple and Resistance thermometer) |
Voltage output (for driving SSR) | 2 points | 2 points | Standard | Screwless push-in (NX-TBA162) | 12 mm | NX-TC2405 |
– | NX-TC2406 | |||||||||
4 points | Heating and Cooling | NX-TC2407 | ||||||||
Linear current output | 2 points | Standard | NX-TC2408 | |||||||
4 | Voltage output (for driving SSR) | 4 points | 4 points | Standard | Screwless push-in (NX-TBA162 + NX-TBB162) |
24 mm | NX-TC3405 | |||
– | NX-TC3406 | |||||||||
8 points | Heating and Cooling | NX-TC3407 | ||||||||
Linear current output | 4 points | Standard | NX-TC3408 |
Heater burnout detection units
Module type | Channels, signal type | Control output | I/O refresh method | Connection type
2
Units with screwless push-in
connections are supplied with the appropriate terminal connector.
Units with MIL/Fujitsu connectors are supplied without matching
plugs. |
Width | Order code |
---|---|---|---|---|---|---|
Heater burnout detection | 4 CT inputs 4 control outputs |
NPN, 12 to 24 VDC 0.1 A/point, 0.4 A/unit |
Free Run | Screwless push-in (NX-TBA162) | 12 mm | NX-HB3101 |
PNP 24 VDC 0.1 A/point, 0.4 A/unit |
NX-HB3201 |
Load cell input unit
Module type | Specifications | Excitation voltage/input range | I/O refresh method | Connection type
2
Units with screwless push-in
connections are supplied with the appropriate terminal connector.
Units with MIL/Fujitsu connectors are supplied without matching
plugs. |
Width | Order code |
---|---|---|---|---|---|---|
Load cell input | 1 load cell input, 125 µs conversion cycle | 5 VDC ±10%/–5 to 5 mV/V | Synchronous/ Free Run |
Screwless push-in (NX-TBC162) | 12 mm | NX-RS1201 |
Position control units
Module type | Channels, Signal type | Performance
2 ,
I/O Refresh ModeDigital I/O performance
Order codes are for PNP-type signals (positive switching, 0 V common). Most models are also available as NPN-type (negative switching, 24 V common). Inputs of MIL-connector versions can be used as NPN or PNP. |
Connection type
2
Units with screwless push-in
connections are supplied with the appropriate terminal connector.
Units with MIL/Fujitsu connectors are supplied without matching
plugs. |
Width | Order code | NPN-type
2
Order codes are for PNP-type signals
(positive switching, 0 V common). Most models are also available
as NPN-type (negative switching, 24 V common). Inputs of MIL-connector
versions can be used as NPN or PNP. |
||||||||||||||||||||||||||||||||||||
---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
Encoder Input | 1 SSI encoder, 2 MHz | Synchronous/Free Run | Screwless push-in (NX-TBA122) | 12 mm | NX-ECS112 | – | ||||||||||||||||||||||||||||||||||||
2 SSI encoders, 2 MHz | NX-ECS212 | – | ||||||||||||||||||||||||||||||||||||||||
1 incremental encoder line driver 4 MHz + 3 Digital Inputs (1 µs) | Screwless push-in (NX-TBA122 + NX-TBB122) |
24 mm | NX-EC0142 | NX-EC0132 | ||||||||||||||||||||||||||||||||||||||
1 incremental encoder open collector 500 kHz + 3 Digital Inputs (1 µs) | Screwless push-in (NX-TBA162) | 12 mm | NX-EC0122 | NX-EC0112 | ||||||||||||||||||||||||||||||||||||||
2 incremental encoders open collector 500 kHz | Screwless push-in (NX-TBA122) | NX-EC0222 | NX-EC0212 | |||||||||||||||||||||||||||||||||||||||
Pulse Output | 1 Pulse Up/Down or Pulse/Direction open collector 500 kHz + 2 Digital -Inputs + 1 Digital Output (1 µs) | Synchronous | Screwless push-in (NX-TBA162) | 12 mm | NX-PG0122 | NX-PG0112 | ||||||||||||||||||||||||||||||||||||
2 pulse line driver 4 MHz + 5 digital inputs per channel + 3 digital outputs per channel | 1 × 34-pin MIL connector | 30 mm | NX-PG0242-5 | NX-PG0232-5 | ||||||||||||||||||||||||||||||||||||||
4 pulse line driver 4 MHz + 5 digital inputs per channel + 3 digital outputs per channel | 2 × 34-pin MIL connector | NX-PG0342-5 | NX-PG0332-5 |
Serial communication interface units
Module type | Channels, Signal type | Performance
2 ,
I/O Refresh ModeDigital I/O performance
Order codes are for PNP-type signals (positive switching, 0 V common). Most models are also available as NPN-type (negative switching, 24 V common). Inputs of MIL-connector versions can be used as NPN or PNP. |
Connection type
2
Units with screwless push-in
connections are supplied with the appropriate terminal connector.
Units with MIL/Fujitsu connectors are supplied without matching
plugs. |
Width | Order code | NPN-type
2
Order codes are for PNP-type signals
(positive switching, 0 V common). Most models are also available
as NPN-type (negative switching, 24 V common). Inputs of MIL-connector
versions can be used as NPN or PNP. |
||||||||||||||||||||||||||||||||||||
---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
Serial Communication | 1 × RS-422A/485 | Free Run | Screwless push-in (NX-TBC162) | 12 mm | NX-CIF105 | – | ||||||||||||||||||||||||||||||||||||
1 × RS-232C | NX-CIF101 | – | ||||||||||||||||||||||||||||||||||||||||
2 × RS-232C | 9-pin D-sub | 30 mm | NX-CIF210 | – |
Other units
Module type | Description | Connection type
2
Units with screwless push-in
connections are supplied with the appropriate terminal connector.
Units with MIL/Fujitsu connectors are supplied without matching
plugs. |
Width | Order code |
---|---|---|---|---|
Power Unit | NX bus power supply unit, 24 V DC input, non-isolated | Screwless push-in (NX-TBC082) | 12 mm | NX-PD1000 |
I/O power feed unit, for separation of power groups, up to 10 A | Screwless push-in (NX-TBA082) | NX-PF0730 | ||
I/O power connection unit, 16 × IOV | Screwless push-in (NX-TBA162) | NX-PC0020 | ||
I/O power connection unit, 16 × IOG | NX-PC0010 | |||
I/O power connection, 8 × IOV + 8 x IOG | NX-PC0030 | |||
System Units and -Accessories | Grounding terminal, 16 points | Screwless push-in (NX-TBC162) | NX-TBX01 | |
End cover (included with Communication Coupler) | – | NX-END01 | ||
Replacement front connector with 8 wiring terminals (marked A+B) | Screwless push-in | NX-TBA082 | ||
Replacement front connector with 12 wiring terminals (marked A+B) | NX-TBA122 | |||
Replacement front connector with 16 wiring terminals (marked A+B) | NX-TBA162 | |||
Replacement front connector with 12 wiring terminals (marked C+D) | NX-TBB122 | |||
Replacement front connector with 16 wiring terminals (marked C+D) | NX-TBB162 | |||
Replacement front connector with 8 wiring terminals (marked A+B+FG) | NX-TBC082 | |||
Replacement front connector with 16 wiring terminals (marked A+B+FG) | NX-TBC162 | |||
DIN rail insulation spacers, set of 3 pcs | – | NX-AUX01 | ||
30 Unit pins + 30 Terminal keying pins, to prevent mismatch of unit and terminal block (one set is enough for 10 units) | – | NX-AUX02 |
Recommended EtherCAT and EtherNet/IP communication cables
Item | Manufacturer | Color | Cable length (m) | Order code | ||
---|---|---|---|---|---|---|
EtherCAT cable |
Cat 5e, AWG22, 2-pair cable M12/Smartclick connectors Improved shield for EtherCATcommunications |
Standard type Cable with connectors on both ends (M12 straight/M12 straight) |
OMRON | Black | 0.5 | XS5W-T421-BM2-SS |
1 | XS5W-T421-CM2-SS | |||||
2 | XS5W-T421-DM2-SS | |||||
3 | XS5W-T421-EM2-SS | |||||
5 | XS5W-T421-GM2-SS | |||||
10 | XS5W-T421-JM2-SS | |||||
Rugged type Cable with connectors on both ends (M12 straight/RJ45) ![]() |
Black | 0.5 | XS5W-T421-BMCSS | |||
1 | XS5W-T421-CMC-SS | |||||
2 | XS5W-T421-DMC-SS | |||||
3 | XS5W-T421-EMC-SS | |||||
5 | XS5W-T421-GMC-SS | |||||
10 | XS5W-T421-JMC-SS | |||||
Ethernet/EtherCAT patch cable |
Cat 6a, AWG27, 4-pair cable Cable sheath material: LSZH
2 ,The lineup features
low smoke zero halogen cables for in-cabinet use and PUR cables
for out-of-cabinet use.
2
This cable is available
in yellow, green and blue colors. |
Standard type Cable with connectors on both ends (RJ45/RJ45)![]() |
Yellow | 0.2 | XS6W-6LSZH8SS20CM-Y | |
0.3 | XS6W-6LSZH8SS30CM-Y | |||||
0.5 | XS6W-6LSZH8SS50CM-Y | |||||
1 | XS6W-6LSZH8SS100CM-Y | |||||
1.5 | XS6W-6LSZH8SS150CM-Y | |||||
2 | XS6W-6LSZH8SS200CM-Y | |||||
3 | XS6W-6LSZH8SS300CM-Y | |||||
5 | XS6W-6LSZH8SS500CM-Y | |||||
7.5 | XS6W-6LSZH8SS750CM-Y | |||||
10 | XS6W-6LSZH8SS1000CM-Y | |||||
15 | XS6W-6LSZH8SS1500CM-Y | |||||
20 | XS6W-6LSZH8SS2000CM-Y | |||||
Green | 0.2 | XS6W-6LSZH8SS20CM-G | ||||
0.3 | XS6W-6LSZH8SS30CM-G | |||||
0.5 | XS6W-6LSZH8SS50CM-G | |||||
1 | XS6W-6LSZH8SS100CM-G | |||||
1.5 | XS6W-6LSZH8SS150CM-G | |||||
2 | XS6W-6LSZH8SS200CM-G | |||||
3 | XS6W-6LSZH8SS300CM-G | |||||
5 | XS6W-6LSZH8SS500CM-G | |||||
7.5 | XS6W-6LSZH8SS750CM-G | |||||
10 | XS6W-6LSZH8SS1000CM-G | |||||
15 | XS6W-6LSZH8SS1500CM-G | |||||
20 | XS6W-6LSZH8SS2000CM-G | |||||
Cat 5e, AWG26, 4-pair cable Cable sheath material: PUR
2
The lineup features
low smoke zero halogen cables for in-cabinet use and PUR cables
for out-of-cabinet use. |
Standard type Cable with connectors on both ends (RJ45/RJ45) ![]() |
Green | 0.5 | XS6W-5PUR8SS50CM-G | ||
1 | XS6W-5PUR8SS100CM-G | |||||
1.5 | XS6W-5PUR8SS150CM-G | |||||
2 | XS6W-5PUR8SS200CM-G | |||||
3 | XS6W-5PUR8SS300CM-G | |||||
5 | XS6W-5PUR8SS500CM-G | |||||
7.5 | XS6W-5PUR8SS750CM-G | |||||
10 | XS6W-5PUR8SS1000CM-G | |||||
15 | XS6W-5PUR8SS1500CM-G | |||||
20 | XS6W-5PUR8SS2000CM-G | |||||
Cat 5e, AWG22, 2-pair cable |
Rugged type Cable with connectors on both ends (RJ45/RJ45) ![]() |
OMRON | Grey | 0.3 | XS5W-T421-AMD-K | |
0.5 | XS5W-T421-BMD-K | |||||
1 | XS5W-T421-CMD-K | |||||
2 | XS5W-T421-DMD-K | |||||
3 | XS5W-T421-EMD-K | |||||
5 | XS5W-T421-GMD-K | |||||
10 | XS5W-T421-JMD-K | |||||
15 | XS5W-T421-KMD-K | |||||
Rugged type Cable with connectors on both ends (M12 straight/RJ45) ![]() |
Grey | 0.3 | XS5W-T421-AMC-K | |||
0.5 | XS5W-T421-BMC-K | |||||
1 | XS5W-T421-CMC-K | |||||
2 | XS5W-T421-DMC-K | |||||
3 | XS5W-T421-EMC-K | |||||
5 | XS5W-T421-GMC-K | |||||
10 | XS5W-T421-JMC-K | |||||
15 | XS5W-T421-KMC-K | |||||
Ethernet/EtherCAT patch cable |
Cat 5e, AWG22, 2-pair cable |
Rugged type Cable with connectors on both ends (M12 L right angle/RJ45) ![]() |
OMRON | Grey | 0.3 | XS5W-T422-AMC-K |
0.5 | XS5W-T422-BMC-K | |||||
1 | XS5W-T422-CMC-K | |||||
2 | XS5W-T422-DMC-K | |||||
3 | XS5W-T422-EMC-K | |||||
5 | XS5W-T422-GMC-K | |||||
10 | XS5W-T422-JMC-K | |||||
15 | XS5W-T422-KMC-K | |||||
Ethernet -installation -cable | Cat 5, SF/UTP, 4 × 2 × AWG 24/1 (solid core), Polyurethane (PUR) | Weidmüller | Green | 100 | WM IE-5IC4x2xAWG24/1-PUR | |
Cat 5, SF/UTP, 4 × 2 × AWG 26/7 (stranded core), Polyurethane (PUR) | Green | 100 | WM IE-5IC4x2xAWG26/7-PUR | |||
Connectors |
RJ45 metallic connector For AWG22 to AWG26 |
![]() |
– | – | WM IE-T0-RJ45-FH-BK | |
RJ45 plastic connector For AWG22 to AWG24 |
![]() |
OMRON | – | – | XS6G-T421-1 | |
RJ45 socket | DIN-rail mount socket to terminate installation cable in the -cabinet | Weidmüller | – | – | WM IE-T0-RJ45-FJ-B |
Please be careful while cable processing, for EtherCAT, connectors on both ends should be shield connected and for EtherNet/IP, connectors on only one end should be shield connected.
Accessories
Appearance | Specifications | Order code | ||
---|---|---|---|---|
![]() |
EtherCAT junction slaves |
3 ports Power supply voltage: 20.4 to 28.8 VDC (24 VDC –15 to 20%) Current consumption: 0.08 A |
GX-JC03 | |
![]() |
6 ports Power supply voltage: 20.4 to 28.8 VDC (24 VDC –15 to 20%) Current consumption: 0.17 A |
GX-JC06 | ||
![]() |
Industrial switching hubs (for EtherNet/IP and Ethernet) |
Quality of Service (QoS): EtherNet/IP control data priority. Failure detection: Broadcast storm and LSI error detection 10/100 BASE-TX, Auto-Negotiation Current consumption: 0.22 A |
3 ports Power supply connector included |
W4S1-03B |
5 ports Power supply connector included |
W4S1-05B | |||
5 ports Power supply connector and connector for informing error -included |
W4S1-05C | |||
![]() |
SD memory card | 2 GB | HMC-SD291 | |
4 GB | HMC-SD491 | |||
![]() |
DIN track | Length: 0.5 m; height: 7.3 mm | PFP-50N | |
Length: 1 m; height: 7.3 mm | PFP-100N | |||
Length: 1 m; height: 16 mm | PFP-100N2 | |||
![]() |
End plate to secure the units on the DIN rail | PFP-M (2 pcs) | ||
![]() |
Battery for NX/NJ CPU unit | CJ1W-BAT01 | ||
![]() |
End cover |
End cover for NX1 and NX1P CPU units (Provided with the CPU unit) |
NX-END02 | |
End cover for EtherCAT communication coupler unit (Provided with the EtherCAT communication coupler unit) |
NX-END01 |
Computer software
Specifications | Order code |
---|---|
Sysmac Studio Lite Edition
2 version 1.23 or higherSame functionality
and supported devices than Sysmac Studio Standard Edition except
for controller. The Lite Edition only supports the NX1, NX1P and
NJ1 machine controllers. |
SYSMAC-LE____
2
Refer
to the Sysmac Studio datasheet (Cat. No. SysCat_I181E) for detailed
information or contact your OMRON representative. |
How can we help you?
If you have a question or would like to ask for a quote, please contact us or send a request.
Contact me NX1

Thank you for submitting your request. We will come back to you as soon as possible.
We are experiencing technical difficulties. Your form submission has not been successful. Please accept our apologies and try again later. Details: [details]
DownloadQuotation for NX1
By completing this form you can request a quotation. Your personal details will be handled confidentially.

Thank you for requesting a quotation. We will provide you with the required information as soon as possible.
We are experiencing technical difficulties. Your form submission has not been successful. Please accept our apologies and try again later. Details: [details]
DownloadEtherCAT Redundancy

Redundancy minimizes downtime
Even if a part of the EtherCAT network is disconnected, Cable Redundancy provides continuous connectivity.
This function allows you to fix disconnection without stopping the machines and production line where one controller provides both machine control and safety control.
Direct access to SQL Database
Stored procedure

What is stored procedure?
Stored procedure is one of the database functions. A group of SQL statements is stored in a database, enabling complex processing to be executed with one call. The Stored Procedure Call function to call stored procedure in a database from the controller has been added to version 2.0.

Secure connection between FA and IT
Authentication based on server certificates and encrypted communications ensure safe connection between a database server and the CPU unit.*1

5 times faster data collection than the previous method
Batch Insert can store various types of data for a long time, just like an event data recorder. This allows you to identify the causes of line stoppages by analyzing data collected every scan.*1*2

Automatic generation of tables from structures and vice versa
A database table can be automatically generated from a structure, and a structure can be automatically generated from a database table. Mapping time can be reduced.*1
1. Available in NX701-1□20 and NX102-□□20. Will be available in NJ□01-□□20 soon.
2. Compared with when multiple insertions are performed.
3. A stored procedure is required to delete tables.
Related products
Downloads


_cg_en.jpg)
_cg_en.jpg)
_cg_en.jpg)

_cg_en.jpg)
_cg_en.jpg)
_cg_en.jpg)